DoesTheMath

Westinghouse HW199

0.81 UEF DOE CCD · 2026-09-19
G

Grade G: where this UEF sits among the 397 models in its class, lowest (G) to highest (A). A position, not an official label. How the grade is set

A gas tankless unit, high draw pattern (a larger household, or one where showers and laundry overlap).

If you are checking the Westinghouse HW199, this gas tankless unit uses 209 therms of natural gas a year. That figure applies to the high draw pattern, the standard daily hot-water usage DOE tests against. It sits 27 therms above the 182 therms median for its class and ranks 323rd lowest in energy use of 397.


Energy use per year

209 therms a year

Computed by this site from the registry's UEF and the federal test's daily hot-water draw for this draw pattern. What it costs depends on the natural gas rate where you live.

That is above the median of 182 therms for the 397 models registered in the same heater type and draw pattern; it ranks 323 of 397, lowest energy first.

This model: 209 therms

Solid line: this model (209 therms). Dashed line: the class median.

Min 173 therms Median 182 therms Max 209 therms

DOE CCD · 2026-09-19

Report an issue with this number


What it costs to run where you live

Enter your ZIP to see what this unit costs to run a year at your state’s average natural gas price.


What the registry files

UEF (Uniform Energy Factor) how much hot water you get for each unit of energy the heater uses
0.81 DOE CCD · 2026-09-19 Compared only with other models registered as a gas tankless unit at the high draw pattern.
Draw Pattern the standard daily usage profile DOE tests the unit against
High DOE CCD · 2026-09-19
Maximum Gallons Per Minute how many gallons a minute it can heat while running continuously
5 gal/min DOE CCD · 2026-09-19

What it costs to install

$1,698–$2,632 installed

Not a quote — a modeled range of what installers have charged for this class of unit; your price will vary with labor rates, access, and local code requirements.

Escalation indexes: equipment (BLS PPI) latest available: August 2026; labor (BLS ECI) latest available: April 2026 to June 2026.

NLR REMDB (BLS PPI/ECI escalated) · 2026-04-01

Report an issue with this number


Safety record

No CPSC recall names this model.

Checked against the CPSC recall database. CPSC does not publish a model-level match for this product category, so this list is curated by hand from the manufacturer's recall filings.

CPSC · 2026-09-24

What these figures mean

This site calculated the 209 therms figure. The registry does not publish it. The calculation uses the registry's UEF, the ratio of hot water delivered to energy used, and the daily hot-water draw in the DOE test for the high draw pattern. The UEF for the HW199 is 0.81. The source is the DOE CCD, retrieved 2026-09-19. The figure is only valid at that test draw. A household that uses more or less hot water each day will use a different amount of gas, and this page does not give that amount. The steps and inputs are listed in how the annual cost is calculated.

The high draw pattern stands for a larger household, or one where showers and laundry overlap. The registered maximum flow rate in gallons per minute for the HW199 is 5. Its class is the 397 models registered as gas tankless units at the high draw pattern. Within that class, its energy use falls in the highest quarter: it ranks 323rd lowest of 397 at the test draw. If you need a lower annual gas figure at the same draw pattern, most registered models in this class use less. To compare it with units in the same class, use the same-class replacement search by model number.

The text of this page does not give a running cost. The cost of 209 therms of natural gas depends on the average residential gas price in your state, so the page calculates it from your ZIP. That same rate sets the cost of the 27 therms gap between this unit and the 182 therms class median. This text does not give a figure for that gap. You can work out both figures with the cost calculator for your own ZIP. The installed price range is shown in its own block, with its source and date. It is a modeled installed-cost range, not a quote.

DOE CCD · 2026-09-19

How this compares

The closest models in the same class — same fuel, type and draw pattern.


Keep going