DoesTheMath

VESTA VTP-199

0.96 UEF DOE CCD · 2026-09-19
A

Grade A: where this UEF sits among the 397 models in its class, lowest (G) to highest (A). A position, not an official label. How the grade is set

A gas tankless unit, high draw pattern (a larger household, or one where showers and laundry overlap).

If you are checking the VESTA VTP-199, this gas tankless unit uses 176 therms of natural gas a year. That figure belongs to the high draw pattern, the standard daily hot-water usage DOE tests against. It sits 6 therms below the 182 therms median of the 397 gas tankless models registered at that pattern.


Energy use per year

176 therms a year

Computed by this site from the registry's UEF and the federal test's daily hot-water draw for this draw pattern. What it costs depends on the natural gas rate where you live.

That is below the median of 182 therms for the 397 models registered in the same heater type and draw pattern; it ranks 12 of 397, lowest energy first.

This model: 176 therms

Solid line: this model (176 therms). Dashed line: the class median.

Min 173 therms Median 182 therms Max 209 therms

DOE CCD · 2026-09-19

Report an issue with this number


What it costs to run where you live

Enter your ZIP to see what this unit costs to run a year at your state’s average natural gas price.


What the registry files

UEF (Uniform Energy Factor) how much hot water you get for each unit of energy the heater uses
0.96 DOE CCD · 2026-09-19 Compared only with other models registered as a gas tankless unit at the high draw pattern.
Draw Pattern the standard daily usage profile DOE tests the unit against
High DOE CCD · 2026-09-19
Maximum Gallons Per Minute how many gallons a minute it can heat while running continuously
6 gal/min DOE CCD · 2026-09-19
On the market since (ENERGY STAR) the date the manufacturer told ENERGY STAR the model went on sale
2023-10-16 ENERGY STAR · 2026-09-19
Connected / demand response (ENERGY STAR) whether the unit can take signals from your utility to shift when it heats, and by which standard (such as CTA-2045)
No ENERGY STAR · 2026-09-19

What it costs to install

$2,405–$3,460 installed

Not a quote — a modeled range of what installers have charged for this class of unit; your price will vary with labor rates, access, and local code requirements.

Escalation indexes: equipment (BLS PPI) latest available: August 2026; labor (BLS ECI) latest available: April 2026 to June 2026.

NLR REMDB (BLS PPI/ECI escalated) · 2026-04-01

Report an issue with this number


Safety record

Checked against the CPSC recall database. CPSC does not publish a model-level match for this product category, so this list is curated by hand from the manufacturer's recall filings.

CPSC · 2026-09-24

Does it fit your space?

Enter your own numbers below — this compares them to what ENERGY STAR publishes for this model, it does not tell you what to buy.

Dimensions (ENERGY STAR)
the unit's filed height, width, depth or tank diameter, in inches
Input voltage and maximum current (ENERGY STAR)
the circuit voltage the unit is certified on and the most current it draws
Vent type and size (ENERGY STAR)
how a gas unit is vented, the vent's diameter and the height of its vent connector
  • Physical footprintEnter your numbers27.6" H × 18.1" W × 11.6" D × 18.1" ⌀
  • Electrical supplyEnter your numbers5A max
  • Vent compatibilityEnter your numbersDirect Vent, 2" or 2" vent, 720" to vent
ENERGY STAR · 2026-09-19

What these figures mean

This site computes the 176 therms figure; it is not taken from the registry. It combines two inputs. The first is the registry's UEF, the ratio of hot water delivered to energy used, which is 0.96 for this model. The second is the daily hot-water draw the DOE test sets for the high pattern. Both come from the DOE Compliance Certification Database (CCD), retrieved 2026-09-19. The figure holds only at the test's daily draw. A home that draws more or less hot water each day will use more or less gas. The page on how the annual cost is calculated sets out each step. Among the 397 models in its class, this unit ranks 12th lowest in energy use, which places it in the lowest quarter of its class.

The high draw pattern describes a larger household, or one where showers and laundry overlap. Because the 176 therms figure is tied to that pattern, it applies most directly to homes with that level of use. A smaller household with a lower daily draw will likely use less gas than the stated figure, but the data here do not show this model's energy use at other draw patterns. The registry lists a maximum flow rate in gallons per minute of 6. The data do not state the temperature rise behind that rating, so whether it covers several fixtures at once in a given home is unknown here. To compare other heaters by these factors, use the water heater selector by fuel, space and size.

This text does not give a running cost. The cost depends on your state's average residential gas price, so the page calculates it from your ZIP code. You can check it with the cost calculator on your own ZIP. The 6 therms gap to the class median is also measured at the test's daily draw. What that gap is worth each year depends on the same gas price. A separate block on this page shows the installed price as a modeled range, with its source and date. That range is not a quote. If you are verifying a like-for-like swap, you can find a same-class replacement by model number among the 397 gas tankless models at the high pattern.

DOE CCD · 2026-09-19

How this compares

The closest models in the same class — same fuel, type and draw pattern.