VESTA VTP-150
0.96 UEF DOE CCD · 2026-09-19Grade A: where this UEF sits among the 397 models in its class, lowest (G) to highest (A). A position, not an official label. How the grade is set
A gas tankless unit, high draw pattern (a larger household, or one where showers and laundry overlap).
If you are checking the VESTA VTP-150, this gas tankless unit uses 176 therms of natural gas a year. That figure belongs to the high draw pattern, the standard daily hot-water usage DOE tests against. It sits 6 therms below the class median of 182 therms, the 12th lowest of 397 comparable models.
Energy use per year
176 therms a year
Computed by this site from the registry's UEF and the federal test's daily hot-water draw for this draw pattern. What it costs depends on the natural gas rate where you live.
That is below the median of 182 therms for the 397 models registered in the same heater type and draw pattern; it ranks 12 of 397, lowest energy first.
Solid line: this model (176 therms). Dashed line: the class median.
Min 173 therms Median 182 therms Max 209 therms
What it costs to run where you live
What the registry files
- UEF (Uniform Energy Factor) how much hot water you get for each unit of energy the heater uses
- 0.96 DOE CCD · 2026-09-19 Compared only with other models registered as a gas tankless unit at the high draw pattern.
- Draw Pattern the standard daily usage profile DOE tests the unit against
- High DOE CCD · 2026-09-19
- Maximum Gallons Per Minute how many gallons a minute it can heat while running continuously
- 4.7 gal/min DOE CCD · 2026-09-19
- On the market since (ENERGY STAR) the date the manufacturer told ENERGY STAR the model went on sale
- 2023-10-16 ENERGY STAR · 2026-09-19
- Connected / demand response (ENERGY STAR) whether the unit can take signals from your utility to shift when it heats, and by which standard (such as CTA-2045)
- No ENERGY STAR · 2026-09-19
What it costs to install
$2,405–$3,460 installed
Not a quote — a modeled range of what installers have charged for this class of unit; your price will vary with labor rates, access, and local code requirements.
Escalation indexes: equipment (BLS PPI) latest available: August 2026; labor (BLS ECI) latest available: April 2026 to June 2026.
NLR REMDB (BLS PPI/ECI escalated) · 2026-04-01Safety record
- VESTA.DS recalls VST brand tankless water heaters 2025-10-16 Covers some units only: Units sold November 2018 through April 2022. Check the serial number on your rating plate.
Checked against the CPSC recall database. CPSC does not publish a model-level match for this product category, so this list is curated by hand from the manufacturer's recall filings.
CPSC · 2026-09-24Does it fit your space?
Enter your own numbers below — this compares them to what ENERGY STAR publishes for this model, it does not tell you what to buy.
- Dimensions (ENERGY STAR)
- the unit's filed height, width, depth or tank diameter, in inches
- Input voltage and maximum current (ENERGY STAR)
- the circuit voltage the unit is certified on and the most current it draws
- Vent type and size (ENERGY STAR)
- how a gas unit is vented, the vent's diameter and the height of its vent connector
What these figures mean
How this compares
The closest models in the same class — same fuel, type and draw pattern.
Keep going
How every figure on this page is calculated
-
Find what replaces your water heater
Enter the model number off your old unit and see what is on file today, with the yearly cost difference.
-
Find a water heater that fits
Three questions — fuel, hot water need, install space — narrow every model on file to the ones that fit.
-
What a water heater costs to run
Prices a unit's efficiency against your own utility's filed tariff for your ZIP code.
-
How to size a tankless water heater by GPM
Answered from what models in this size actually file.
-
Water heaters
Every model on file with the Department of Energy, by heater type.
-
All gas tankless water heaters
Gas-fired instantaneous units, sized by flow rate rather than tank gallons.
-
Every VESTA model on file
What this brand files, by heater type.
UEF 0.96 · Grade A Price it on your ZIP
The 176 therms figure is computed by this site, not taken from the registry. It combines the registry's UEF, the ratio of hot water delivered to energy used, with the DOE test's daily hot-water draw for the high draw pattern. For the VTP-150, the listed UEF is 0.96. The underlying data comes from DOE CCD, retrieved 2026-09-19. The figure holds only at the federal test's daily draw. A home drawing a different amount of hot water will use a different amount of gas, and this data does not show how much. The 6 therms gap to the class median is measured under that same test condition. Each step behind the figure is set out in our method for the annual energy and cost figures.
The high draw pattern stands for a larger household, or one where showers and laundry overlap. The VTP-150 lists a maximum flow rate in gallons per minute of 4.7. Among the 397 models registered as a gas tankless unit at the high draw pattern, it ranks 12th lowest for energy use. That places it in the lowest quarter of its class. The comparison covers only this class; it does not include tank, electric or heat pump heaters. For a smaller household that draws less hot water than the high pattern assumes, the 176 therms figure does not describe its use. A figure for lower draw is not available in this data. Heaters of other fuels and sizes can be compared with the water heater selector by fuel, space and size.
The text on this page does not state a running cost for the VTP-150. The cost of 176 therms of natural gas depends on your state's average residential gas price. The page therefore computes it from your ZIP in its own block. That cost carries the same condition as the energy figure: the high draw pattern's test draw. The 6 therms difference from the class median is also priced only at your own rate. To run the figure on your rate, use the running cost calculator for your ZIP. The installed price range shown elsewhere on this page is a modeled range with its own source and date, not a quote. If you are matching a unit already in place, you can find a same-class replacement by model number.
DOE CCD · 2026-09-19