DoesTheMath

VAUGHN THERMAL MP80FHPT

3.5 UEF DOE CCD · 2026-09-19
C

Grade C: where this UEF sits among the 194 models in its class, lowest (G) to highest (A). A position, not an official label. How the grade is set

An electric tank, high draw pattern (a larger household, or one where showers and laundry overlap).

If you are checking the VAUGHN THERMAL MP80FHPT, this electric tank uses 1,417 kWh of electricity a year at the high draw pattern, the standard daily hot-water usage DOE tests against. That is 111 kWh above the class median of 1,306 kWh, ranking 119th lowest energy use of 194 models.


Energy use per year

1,417 kWh a year

Computed by this site from the registry's UEF and the federal test's daily hot-water draw for this draw pattern. What it costs depends on the electricity rate where you live.

That is above the median of 1,306 kWh for the 194 models registered in the same heater type and draw pattern; it ranks 119 of 194, lowest energy first.

This model: 1,417 kWh

Solid line: this model (1,417 kWh). Dashed line: the class median.

Min 1,002 kWh Median 1,306 kWh Max 5,334 kWh

DOE CCD · 2026-09-19

Report an issue with this number


What it costs to run where you live

Enter your ZIP to see what this unit costs to run a year on your own utility’s electricity rate.


What the registry files

UEF (Uniform Energy Factor) how much hot water you get for each unit of energy the heater uses
3.5 DOE CCD · 2026-09-19 Compared only with other models registered as an electric tank at the high draw pattern.
Draw Pattern the standard daily usage profile DOE tests the unit against
High DOE CCD · 2026-09-19
First Hour Rating how many gallons of hot water the unit can deliver in one hour, starting from a full tank
86 gal DOE CCD · 2026-09-19
Rated Storage Volume the tank size in gallons
80 gal DOE CCD · 2026-09-19
On the market since (ENERGY STAR) the date the manufacturer told ENERGY STAR the model went on sale
2025-06-01 ENERGY STAR · 2026-09-19
Connected / demand response (ENERGY STAR) whether the unit can take signals from your utility to shift when it heats, and by which standard (such as CTA-2045)
No ENERGY STAR · 2026-09-19
Refrigerant and GWP (ENERGY STAR) the refrigerant a heat pump unit uses and its global warming potential, a leak's climate effect relative to carbon dioxide (CO2 = 1)
R-134a, GWP 1430 ENERGY STAR · 2026-09-19
Sound level (ENERGY STAR) how loud the unit is while it runs, in decibels as filed
54 dB ENERGY STAR · 2026-09-19

What it costs to install

$4,130–$4,480 installed

Not a quote — a modeled range of what installers have charged for this class of unit; your price will vary with labor rates, access, and local code requirements.

Escalation indexes: equipment (BLS PPI) latest available: August 2026; labor (BLS ECI) latest available: April 2026 to June 2026.

NLR REMDB (BLS PPI/ECI escalated) · 2026-04-01

Report an issue with this number


Safety record

No CPSC recall names this model.

Checked against the CPSC recall database. CPSC does not publish a model-level match for this product category, so this list is curated by hand from the manufacturer's recall filings.

CPSC · 2026-09-24

Does it fit your space?

Enter your own numbers below — this compares them to what ENERGY STAR publishes for this model, it does not tell you what to buy.

Compressor operating range (ENERGY STAR)
the air temperatures around the unit in which its heat pump runs; outside this range the heat pump stops
Dimensions (ENERGY STAR)
the unit's filed height, width, depth or tank diameter, in inches
Input voltage and maximum current (ENERGY STAR)
the circuit voltage the unit is certified on and the most current it draws
  • Ambient temperatureEnter your numbers35°F min
  • Physical footprintEnter your numbers30" ⌀
  • Electrical supplyEnter your numbers240V, 23A max
ENERGY STAR · 2026-09-19

What these figures mean

The 1,417 kWh figure comes from this site's calculation, not from the registry itself. It uses the registry's UEF, the ratio of hot water delivered to energy used, which is 3.5 for this model. The calculation pairs that UEF with the DOE test's daily hot-water draw for the high draw pattern. That pattern stands for a larger household, or one where showers and laundry overlap. The figure therefore holds only at the federal test's draw. A home that uses more or less hot water will see a different yearly total, and that total is not available here. The UEF value comes from the DOE CCD, retrieved 2026-09-19. The page on how the annual cost is calculated explains how the energy figure turns into a yearly cost.

The class here is the 194 models registered as an electric tank at the high draw pattern. The 111 kWh gap noted above puts this model above the median, but outside the quarter of the class with the highest energy use. The model lists a first hour rating, the gallons of hot water available in the first hour from a full tank, of 86 gallons. Its rated volume is 80 gallons. The registry tests it at the high draw pattern, so its figures describe homes near that level of demand. For a household with lighter hot-water use, the 1,417 kWh figure does not describe expected use. Comparisons against other models hold only inside the same class, and you can find a same-class replacement by model number.

This page gives no running cost in the text. The yearly cost of 1,417 kWh of electricity depends on your own utility electricity tariff. That tariff is not part of the registry data. The cost calculator on your own ZIP applies your local rate to this model's figure. On a flat per-kWh rate, the 111 kWh gap above the class median adds to cost in direct proportion to that rate. Tiered or time-of-use tariffs make that link less direct. If your home's actual draw differs from the high draw pattern, your cost will also differ from the calculated one. The installed price range appears in its own block on this page, with its source and date. It is a modeled installed-cost range, not a quote.

DOE CCD · 2026-09-19

How this compares

The closest models in the same class — same fuel, type and draw pattern.


Keep going

UEF 3.5 · Grade C Price it on your ZIP