DoesTheMath

Stiebel Eltron DHC 9-3

0.95 UEF DOE CCD · 2026-09-19
F

Grade F: where this UEF sits among the 271 models in its class, lowest (G) to highest (A). A position, not an official label. How the grade is set

An electric tankless unit, very small draw pattern (small units - a single bathroom, or a point-of-use heater under a sink).

If you are checking the Stiebel Eltron DHC 9-3, an electric tankless unit, it uses 622 kWh of electricity a year. That figure applies at the very small draw pattern, the standard daily hot-water usage DOE tests against. It sits 7 kWh above the 615 kWh median of its class of 271 models.


Energy use per year

622 kWh a year

Computed by this site from the registry's UEF and the federal test's daily hot-water draw for this draw pattern. What it costs depends on the electricity rate where you live.

That is above the median of 615 kWh for the 271 models registered in the same heater type and draw pattern; it ranks 152 of 271, lowest energy first.

This model: 622 kWh

Solid line: this model (622 kWh). Dashed line: the class median.

Min 562 kWh Median 615 kWh Max 649 kWh

DOE CCD · 2026-09-19

Report an issue with this number


What it costs to run where you live

Enter your ZIP to see what this unit costs to run a year on your own utility’s electricity rate.


What the registry files

UEF (Uniform Energy Factor) how much hot water you get for each unit of energy the heater uses
0.95 DOE CCD · 2026-09-19 Compared only with other models registered as an electric tankless unit at the very small draw pattern.
Draw Pattern the standard daily usage profile DOE tests the unit against
Very small DOE CCD · 2026-09-19
Maximum Gallons Per Minute how many gallons a minute it can heat while running continuously
0.9 gal/min DOE CCD · 2026-09-19

What it costs to install

$1,303–$1,814 installed

Not a quote — a modeled range of what installers have charged for this class of unit; your price will vary with labor rates, access, and local code requirements.

Escalation indexes: equipment (BLS PPI) latest available: August 2026; labor (BLS ECI) latest available: April 2026 to June 2026.

NLR REMDB (BLS PPI/ECI escalated) · 2026-04-01

Report an issue with this number


Safety record

No CPSC recall names this model.

Checked against the CPSC recall database. CPSC does not publish a model-level match for this product category, so this list is curated by hand from the manufacturer's recall filings.

CPSC · 2026-09-24

What these figures mean

The 622 kWh figure is computed by this site. The registry does not publish it. It combines the registry's UEF, the ratio of hot water delivered to energy used, with the DOE test's daily hot-water draw for the very small draw pattern. For this model, the registry lists a UEF of 0.95. The source is the DOE CCD, retrieved 2026-09-19. The figure assumes the test's daily draw. A household that draws more or less hot water than the test will have a different yearly total. This page has no measured use from any real home, so that difference is unknown here. The steps behind the figure are set out in how the annual cost is calculated.

The class is the 271 models registered as an electric tankless unit at the very small draw pattern. Within it, this model ranks 152nd lowest in energy use, in the second-highest quarter of its class. The very small draw pattern covers small units: a single bathroom, or a point-of-use heater under a sink. The registry lists a maximum flow rate in gallons per minute of 0.9. So the 622 kWh figure describes use at that scale. It does not describe a home that needs one unit to supply several fixtures at once. For that kind of home, the registry data here gives no annual figure for this model. To compare it with other models in the same class, you can find a same-class replacement by model number.

The text on this page gives no running cost. The yearly cost of 622 kWh depends on your own utility's electricity tariff. For that reason, the page computes the cost from your ZIP instead of a single figure for every reader. To check the cost at a different rate, use the cost calculator for your own ZIP. The installed price range appears in its own block on this page, with its source and date. It is a modeled installed-cost range, not a quote. Neither the running cost nor the installed range changes the energy figure. The 622 kWh value stays tied to the very small draw pattern and the federal test's daily draw.

DOE CCD · 2026-09-19

How this compares

The closest models in the same class — same fuel, type and draw pattern.


Keep going

UEF 0.95 · Grade F Price it on your ZIP