DoesTheMath

STATE UPVA-35E 1**

0.92 UEF DOE CCD · 2026-09-19
G

Grade G: where this UEF sits among the 271 models in its class, lowest (G) to highest (A). A position, not an official label. How the grade is set

An electric tankless unit, very small draw pattern (small units - a single bathroom, or a point-of-use heater under a sink).

If you are checking the STATE UPVA-35E 1**, an electric tankless unit, here is its energy figure. It uses 642 kWh of electricity a year at the very small draw pattern, the standard daily hot-water usage DOE tests against. That is 27 kWh above the 615 kWh median for its class.


Energy use per year

642 kWh a year

Computed by this site from the registry's UEF and the federal test's daily hot-water draw for this draw pattern. What it costs depends on the electricity rate where you live.

That is above the median of 615 kWh for the 271 models registered in the same heater type and draw pattern; it ranks 249 of 271, lowest energy first.

This model: 642 kWh

Solid line: this model (642 kWh). Dashed line: the class median.

Min 562 kWh Median 615 kWh Max 649 kWh

DOE CCD · 2026-09-19

Report an issue with this number


What it costs to run where you live

Enter your ZIP to see what this unit costs to run a year on your own utility’s electricity rate.


What the registry files

UEF (Uniform Energy Factor) how much hot water you get for each unit of energy the heater uses
0.92 DOE CCD · 2026-09-19 Compared only with other models registered as an electric tankless unit at the very small draw pattern.
Draw Pattern the standard daily usage profile DOE tests the unit against
Very small DOE CCD · 2026-09-19
Maximum Gallons Per Minute how many gallons a minute it can heat while running continuously
0.4 gal/min DOE CCD · 2026-09-19

What it costs to install

$1,294–$1,742 installed

Not a quote — a modeled range of what installers have charged for this class of unit; your price will vary with labor rates, access, and local code requirements.

Escalation indexes: equipment (BLS PPI) latest available: August 2026; labor (BLS ECI) latest available: April 2026 to June 2026.

NLR REMDB (BLS PPI/ECI escalated) · 2026-04-01

Report an issue with this number


Safety record

No CPSC recall names this model.

Checked against the CPSC recall database. CPSC does not publish a model-level match for this product category, so this list is curated by hand from the manufacturer's recall filings.

CPSC · 2026-09-24

What these figures mean

The 642 kWh figure is calculated by this site. The registry does not publish it. The calculation starts from the registry's UEF, the ratio of hot water delivered to energy used, which is 0.92 for this model. That ratio is applied to the DOE test's daily hot-water draw for the very small draw pattern. This pattern covers small units: a single bathroom, or a point-of-use heater under a sink. The figure therefore applies at the federal test's draw, not at your household's actual use. If your use differs from the test draw, the figure does not reflect it. The inputs come from DOE CCD, retrieved 2026-09-19. The steps behind the figure are set out on the page explaining how the annual cost is calculated.

The class for this model is the 271 models registered as an electric tankless unit at the very small draw pattern. Among them, it ranks 249th lowest in energy use. That puts it in the highest quarter of its class for energy use, above the median given at the top of this page. The registry lists a maximum flow rate in gallons per minute of 0.4. The draw pattern describes single-bathroom or under-sink use. The data on this page gives no energy figure for any larger draw pattern, so it does not cover heavier household use. To compare lower-energy models in the same class, you can find a same-class replacement by model number.

This text does not state a running cost. The cost depends on your own utility's electricity tariff. The page calculates it from your ZIP by applying your rate to 642 kWh of electricity a year at the test draw. You can run that calculation again with the cost calculator on your own ZIP. At any one rate, this model's cost at the test draw rises with its energy use. At that rate, its cost is higher than a median model's because it uses 27 kWh more energy. The installed price range appears in its own block, with its source and date. It is a modeled range, not a quote, and it is separate from the running cost.

DOE CCD · 2026-09-19

How this compares

The closest models in the same class — same fuel, type and draw pattern.


Keep going

UEF 0.92 · Grade G Price it on your ZIP