DoesTheMath

STATE UPVA-110Y 1**

0.94 UEF DOE CCD · 2026-09-19
F

Grade F: where this UEF sits among the 271 models in its class, lowest (G) to highest (A). A position, not an official label. How the grade is set

An electric tankless unit, very small draw pattern (small units - a single bathroom, or a point-of-use heater under a sink).

If you are checking the STATE UPVA-110Y 1**, this electric tankless unit uses 628 kWh of electricity a year at the federal test's daily hot-water draw. That figure belongs to the very small draw pattern, the standard daily hot-water usage DOE tests against. It sits 13 kWh above the 615 kWh median of its class.


Energy use per year

628 kWh a year

Computed by this site from the registry's UEF and the federal test's daily hot-water draw for this draw pattern. What it costs depends on the electricity rate where you live.

That is above the median of 615 kWh for the 271 models registered in the same heater type and draw pattern; it ranks 188 of 271, lowest energy first.

This model: 628 kWh

Solid line: this model (628 kWh). Dashed line: the class median.

Min 562 kWh Median 615 kWh Max 649 kWh

DOE CCD · 2026-09-19

Report an issue with this number


What it costs to run where you live

Enter your ZIP to see what this unit costs to run a year on your own utility’s electricity rate.


What the registry files

UEF (Uniform Energy Factor) how much hot water you get for each unit of energy the heater uses
0.94 DOE CCD · 2026-09-19 Compared only with other models registered as an electric tankless unit at the very small draw pattern.
Draw Pattern the standard daily usage profile DOE tests the unit against
Very small DOE CCD · 2026-09-19
Maximum Gallons Per Minute how many gallons a minute it can heat while running continuously
1 gal/min DOE CCD · 2026-09-19

What it costs to install

$1,300–$1,790 installed

Not a quote — a modeled range of what installers have charged for this class of unit; your price will vary with labor rates, access, and local code requirements.

Escalation indexes: equipment (BLS PPI) latest available: August 2026; labor (BLS ECI) latest available: April 2026 to June 2026.

NLR REMDB (BLS PPI/ECI escalated) · 2026-04-01

Report an issue with this number


Safety record

No CPSC recall names this model.

Checked against the CPSC recall database. CPSC does not publish a model-level match for this product category, so this list is curated by hand from the manufacturer's recall filings.

CPSC · 2026-09-24

What these figures mean

This site computes the 628 kWh figure; the registry does not publish it. The calculation combines the registry's UEF, the ratio of hot water delivered to energy used, with the daily hot-water draw that the DOE test sets for the very small draw pattern. This unit's UEF is 0.94, taken from the DOE Compliance Certification Database (CCD) and retrieved on 2026-09-19. So the figure describes the test's daily draw, not use measured in a real home. A home that draws more hot water each day than the test will use more electricity than 628 kWh. A home that draws less will use less. The registry holds no field reading for this model, so actual use in any given home is not available. The page on how the annual cost is calculated sets out each step behind this figure.

Among the 271 models registered as an electric tankless unit at the very small draw pattern, this one ranks 188th lowest for energy use. That puts it in the second-highest quarter of its class, the 13 kWh gap above the median noted earlier. The very small draw pattern covers small units, meaning a single bathroom or a point-of-use heater under a sink. The registry lists this model's maximum flow rate in gallons per minute as 1. A job that needs more hot water at once than 1 falls outside what this rating describes. The same applies to a household larger than the single bathroom this draw pattern assumes. To compare other units in the same class, use the tool to find a same-class replacement by model number.

The text of this page gives no running cost for this model. What 628 kWh of electricity costs depends on the reader's own utility electricity tariff, so no figure is estimated here. Instead, the page computes that cost from your ZIP. The cost calculator on your own ZIP applies your rate to the same 628 kWh at the very small draw pattern. The installed-cost range appears in its own block, with its source and date. It is a modeled range, not a quote, and this text does not restate it. The registry data cannot tell you the running cost in a home whose daily draw differs from the federal test. That cost remains unknown until your actual use is measured.

DOE CCD · 2026-09-19

How this compares

The closest models in the same class — same fuel, type and draw pattern.


Keep going

UEF 0.94 · Grade F Price it on your ZIP