DoesTheMath

STATE HPTS-80 2**

3.88 UEF DOE CCD · 2026-09-19
B

Grade B: where this UEF sits among the 194 models in its class, lowest (G) to highest (A). A position, not an official label. How the grade is set

An electric tank, high draw pattern (a larger household, or one where showers and laundry overlap).

If you are verifying STATE HPTS-80 2**: this electric tank uses 1,279 kWh of electricity a year at the high draw pattern, the standard daily hot-water usage DOE tests against. That is 27 kWh below the class median of 1,306 kWh. It ranks 72nd lowest energy use of 194 models.


Energy use per year

1,279 kWh a year

Computed by this site from the registry's UEF and the federal test's daily hot-water draw for this draw pattern. What it costs depends on the electricity rate where you live.

That is below the median of 1,306 kWh for the 194 models registered in the same heater type and draw pattern; it ranks 72 of 194, lowest energy first.

This model: 1,279 kWh

Solid line: this model (1,279 kWh). Dashed line: the class median.

Min 1,002 kWh Median 1,306 kWh Max 5,334 kWh

DOE CCD · 2026-09-19

Report an issue with this number


What it costs to run where you live

Enter your ZIP to see what this unit costs to run a year on your own utility’s electricity rate.


What the registry files

UEF (Uniform Energy Factor) how much hot water you get for each unit of energy the heater uses
3.88 DOE CCD · 2026-09-19 Compared only with other models registered as an electric tank at the high draw pattern.
Draw Pattern the standard daily usage profile DOE tests the unit against
High DOE CCD · 2026-09-19
First Hour Rating how many gallons of hot water the unit can deliver in one hour, starting from a full tank
95 gal DOE CCD · 2026-09-19
Rated Storage Volume the tank size in gallons
82 gal DOE CCD · 2026-09-19
On the market since (ENERGY STAR) the date the manufacturer told ENERGY STAR the model went on sale
2022-06-06 ENERGY STAR · 2026-09-19
Connected / demand response (ENERGY STAR) whether the unit can take signals from your utility to shift when it heats, and by which standard (such as CTA-2045)
Yes (CTA-2045-A,CTA-2045-B) ENERGY STAR · 2026-09-19
Refrigerant and GWP (ENERGY STAR) the refrigerant a heat pump unit uses and its global warming potential, a leak's climate effect relative to carbon dioxide (CO2 = 1)
R-134a, GWP 1430 ENERGY STAR · 2026-09-19

What it costs to install

Not published: Installed cost range

This model's rated tank size lies outside the range NLR REMDB's cost model was fitted on, and the range is not stretched past it.

The annual energy figure on this page does not depend on this range and is unaffected.


Safety record

No CPSC recall names this model.

Checked against the CPSC recall database. CPSC does not publish a model-level match for this product category, so this list is curated by hand from the manufacturer's recall filings.

CPSC · 2026-09-24

Does it fit your space?

Enter your own numbers below — this compares them to what ENERGY STAR publishes for this model, it does not tell you what to buy.

Compressor operating range (ENERGY STAR)
the air temperatures around the unit in which its heat pump runs; outside this range the heat pump stops
Dimensions (ENERGY STAR)
the unit's filed height, width, depth or tank diameter, in inches
Input voltage and maximum current (ENERGY STAR)
the circuit voltage the unit is certified on and the most current it draws
  • Ambient temperatureEnter your numbers37°F min
  • Physical footprintEnter your numbers27" ⌀
  • Electrical supplyEnter your numbers240V, 22A max
ENERGY STAR · 2026-09-19

What these figures mean

The figure of 1,279 kWh was computed by this site, not by the registry. It combines the registry's UEF, the ratio of hot water delivered to energy used, of 3.88 with the DOE test's daily hot-water draw for the high draw pattern. The source is DOE CCD, retrieved 2026-09-19. The figure holds only at that test draw, so a household that draws more or less hot water will use a different amount. Within the 194 electric tank models registered at this draw pattern, the model sits 27 kWh below the class median of 1,306 kWh. Its rank of 72nd lowest places it in the second-lowest quarter of its class for energy use. The method behind the annual figure is documented separately.

The high draw pattern describes a larger household, or one where showers and laundry overlap. The model is registered with a first hour rating, the gallons of hot water available in the first hour from a full tank, of 95 gallons and a rated volume of 82 gallons. Those ratings are the ones the registry lists for this draw pattern. A household with a lighter draw is not described by 1,279 kWh, and this page has no figure for other draw patterns. The gap of 27 kWh from the 1,306 kWh median is a comparison inside this class only. It does not compare the model with other heater types. To compare across fuel, space and size, use the water heater selector.

The running cost is not stated here because it depends on your own utility electricity tariff. The cost calculator takes your ZIP and applies your rate to the 1,279 kWh shown above. The result is a calculation at the test draw, not a measurement of your home. An installed price range is not published for this model. Its ratings of 95 gallons first hour rating and 82 gallons rated volume lie outside the range the cost database's model was fitted on, and the range is not stretched past it. To look for a same-class unit, the replacement finder by model number accepts HPTS-80 2** as a starting point.

DOE CCD · 2026-09-19

How this compares

The closest models in the same class — same fuel, type and draw pattern.


Keep going

UEF 3.88 · Grade B Price it on your ZIP