STATE HPTS-66 2**

3.7 UEF DOE CCD · 2026-09-19
C

Grade C: where this UEF sits among the 194 models in its class, lowest (G) to highest (A). A position, not an official label. How the grade is set

An electric tank, high draw pattern (a larger household, or one where showers and laundry overlap).

You are checking a model against the registry. STATE HPTS-66 2** uses 1,341 kWh of electricity a year at the high draw pattern, the standard daily hot-water usage DOE tests against. That is 35 kWh above the class median of 1,306 kWh. It ranks 101st lowest of 194 models.


Energy use per year

1,341 kWh a year

Computed by this site from the registry's UEF and the federal test's daily hot-water draw for this draw pattern. What it costs depends on the electricity rate where you live.

That is above the median of 1,306 kWh for the 194 models registered in the same heater type and draw pattern; it ranks 101 of 194, lowest energy first.

This model: 1,341 kWh

Solid line: this model (1,341 kWh). Dashed line: the class median.

Min 1,002 kWh Median 1,306 kWh Max 5,334 kWh

DOE CCD · 2026-09-19

Report an issue with this number


What it costs to run where you live

Enter your ZIP to see what this unit costs to run a year on your own utility’s electricity rate.


What the registry files

UEF (Uniform Energy Factor) how much hot water you get for each unit of energy the heater uses
3.7 DOE CCD · 2026-09-19 Compared only with other models registered as an electric tank at the high draw pattern.
Draw Pattern the standard daily usage profile DOE tests the unit against
High DOE CCD · 2026-09-19
First Hour Rating how many gallons of hot water the unit can deliver in one hour, starting from a full tank
82 gal DOE CCD · 2026-09-19
Rated Storage Volume the tank size in gallons
67 gal DOE CCD · 2026-09-19
On the market since (ENERGY STAR) the date the manufacturer told ENERGY STAR the model went on sale
2022-06-06 ENERGY STAR · 2026-09-19
Connected / demand response (ENERGY STAR) whether the unit can take signals from your utility to shift when it heats, and by which standard (such as CTA-2045)
Yes (CTA-2045-A,CTA-2045-B) ENERGY STAR · 2026-09-19
Refrigerant and GWP (ENERGY STAR) the refrigerant a heat pump unit uses and its global warming potential, a leak's climate effect relative to carbon dioxide (CO2 = 1)
R-134a, GWP 1430 ENERGY STAR · 2026-09-19

What it costs to install

$3,732–$4,558 installed

Not a quote — a modeled range of what installers have charged for this class of unit; your price will vary with labor rates, access, and local code requirements.

Escalation indexes: equipment (BLS PPI) latest available: August 2026; labor (BLS ECI) latest available: April 2026 to June 2026.

NLR REMDB (BLS PPI/ECI escalated) · 2026-04-01

Report an issue with this number


Safety record

No CPSC recall names this model.

Checked against the CPSC recall database. CPSC does not publish a model-level match for this product category, so this list is curated by hand from the manufacturer's recall filings.

CPSC · 2026-09-24

Does it fit your space?

Enter your own numbers below — this compares them to what ENERGY STAR publishes for this model, it does not tell you what to buy.

Compressor operating range (ENERGY STAR)
the air temperatures around the unit in which its heat pump runs; outside this range the heat pump stops
Dimensions (ENERGY STAR)
the unit's filed height, width, depth or tank diameter, in inches
Input voltage and maximum current (ENERGY STAR)
the circuit voltage the unit is certified on and the most current it draws
  • Ambient temperatureEnter your numbers37°F min
  • Physical footprintEnter your numbers23" ⌀
  • Electrical supplyEnter your numbers240V, 22A max
ENERGY STAR · 2026-09-19

What these figures mean

The registry lists this model's UEF, the ratio of hot water delivered to energy used, as 3.7. This site combined that UEF with the DOE test's daily hot-water draw for the high draw pattern. The result is 1,341 kWh a year of electricity for the high draw pattern. The registry does not publish this annual figure itself. The energy data come from the DOE CCD, retrieved 2026-09-19. The steps are described under how the annual cost is calculated. Both inputs are set by the registry and the test, so the figure is a calculation and not a metered reading. It applies only to that test draw, so a household's actual use can differ.

Among the 194 models registered as an electric tank at the high draw pattern, the class median is 1,306 kWh a year. This model uses 35 kWh more than that median. Its rank is 101st lowest energy use of 194, which puts it in the second-highest quarter of its class for energy use. A larger rank number means higher energy use within this class. The comparison covers annual energy at the test draw only. It is not a comparison with gas or heat pump models. The registry data do not say how the unit performs in a particular home.

The high draw pattern describes a larger household, or one where showers and laundry overlap. This model's first hour rating, the gallons of hot water available in the first hour from a full tank, is 82 gallons. Its rated volume is 67 gallons. Whether those figures suit a home depends on that home's own hot-water demand, which this page does not measure. Running cost depends on the electricity rate you pay, so it is not stated in the text. Use the cost calculator for your own ZIP to apply your rate to 1,341 kWh. A same-class replacement by model number can be looked up separately.

DOE CCD · 2026-09-19

How this compares

The closest models in the same class — same fuel, type and draw pattern.


Keep going

UEF 3.7 · Grade C Price it on your ZIP