STATE HETF-55 1**
0.94 UEF DOE CCD · 2026-09-19Grade G: where this UEF sits among the 194 models in its class, lowest (G) to highest (A). A position, not an official label. How the grade is set
An electric tank, high draw pattern (a larger household, or one where showers and laundry overlap).
If you are checking the figure for this STATE HETF-55 1**, it uses 5,278 kWh of electricity a year at the high draw pattern, the standard daily hot-water usage DOE tests against. That is 3,972 kWh above the 1,306 kWh class median for 194 electric tank models.
Energy use per year
5,278 kWh a year
Computed by this site from the registry's UEF and the federal test's daily hot-water draw for this draw pattern. What it costs depends on the electricity rate where you live.
That is above the median of 1,306 kWh for the 194 models registered in the same heater type and draw pattern; it ranks 172 of 194, lowest energy first.
Solid line: this model (5,278 kWh). Dashed line: the class median.
Min 1,002 kWh Median 1,306 kWh Max 5,334 kWh
What it costs to run where you live
What the registry files
- UEF (Uniform Energy Factor) how much hot water you get for each unit of energy the heater uses
- 0.94 DOE CCD · 2026-09-19 Compared only with other models registered as an electric tank at the high draw pattern.
- Draw Pattern the standard daily usage profile DOE tests the unit against
- High DOE CCD · 2026-09-19
- First Hour Rating how many gallons of hot water the unit can deliver in one hour, starting from a full tank
- 75 gal DOE CCD · 2026-09-19
- Rated Storage Volume the tank size in gallons
- 55 gal DOE CCD · 2026-09-19
What it costs to install
$1,879–$2,711 installed
Not a quote — a modeled range of what installers have charged for this class of unit; your price will vary with labor rates, access, and local code requirements.
Escalation indexes: equipment (BLS PPI) latest available: August 2026; labor (BLS ECI) latest available: April 2026 to June 2026.
NLR REMDB (BLS PPI/ECI escalated) · 2026-04-01Safety record
No CPSC recall names this model.
Checked against the CPSC recall database. CPSC does not publish a model-level match for this product category, so this list is curated by hand from the manufacturer's recall filings.
CPSC · 2026-09-24What these figures mean
How this compares
The closest models in the same class — same fuel, type and draw pattern.
Keep going
How every figure on this page is calculated
-
Find what replaces your water heater
Enter the model number off your old unit and see what is on file today, with the yearly cost difference.
-
Find a water heater that fits
Three questions — fuel, hot water need, install space — narrow every model on file to the ones that fit.
-
What a water heater costs to run
Prices a unit's efficiency against your own utility's filed tariff for your ZIP code.
-
Is a 50-gallon water heater enough?
Answered from what models in this size actually file.
-
Water heaters
Every model on file with the Department of Energy, by heater type.
-
All electric resistance tank water heaters
Electric tanks that file a UEF below 2.0 — heated by elements, not a heat pump.
-
Every STATE model on file
What this brand files, by heater type.
UEF 0.94 · Grade G Price it on your ZIP
The figure of 5,278 kWh is not a registry entry. This site computed it, not the registry. It used the registry's UEF, the ratio of hot water delivered to energy used. For this model the UEF is 0.94. The other input is the DOE test's daily hot-water draw for the high draw pattern. The source is DOE CCD, retrieved 2026-09-19. The value holds only at that test draw. A household that uses more or less hot water will use a different amount of electricity, and this page has no value for that case. The method is described in how the annual cost is calculated.
Among the 194 models registered as an electric tank at the high draw pattern, this model's rank is 172nd lowest energy use of 194. That places it in the highest quarter of its class for energy use. Its 5,278 kWh is 3,972 kWh above the class median of 1,306 kWh, so most models in the class use less electricity at the same test draw. The high draw pattern describes a larger household, or one where showers and laundry overlap. The registry lists a first hour rating, the gallons of hot water available in the first hour from a full tank, of 75 gallons, and a rated volume of 55 gallons. This page does not judge whether those values meet a given household's demand. For a reader comparing on energy use alone, the rank is the relevant fact, and a same-class replacement can be looked up by model number.
Running cost is not written here because it depends on your own utility electricity rate, which varies by location. Multiplying 5,278 kWh by your rate per kilowatt-hour gives the yearly cost at the test draw. The cost calculator does this from your ZIP code. A modeled installed-cost range appears in its own block on the page, with its source and date. It is not a quote, and its figures are not repeated here. The energy figure is test-based and is not a measurement of an installed unit; metered use in a home is not available in the data. For other fuels, sizes or space limits, the water heater selector covers them.