DoesTheMath

STATE FMDV-50 2**

0.57 UEF DOE CCD · 2026-09-19
G

Grade G: where this UEF sits among the 288 models in its class, lowest (G) to highest (A). A position, not an official label. How the grade is set

A gas tank, medium draw pattern (a typical three- or four-person household, about 55 gallons on a busy morning).

If you are verifying the STATE FMDV-50 2**, this gas tank uses 194 therms of natural gas a year. That figure belongs to the medium draw pattern, the standard daily hot-water usage DOE tests against. It sits 9 therms above the 185 therms median of the 288 gas tank models at that pattern, ranking 278th lowest of 288.


Energy use per year

194 therms a year

Computed by this site from the registry's UEF and the federal test's daily hot-water draw for this draw pattern. What it costs depends on the natural gas rate where you live.

That is above the median of 185 therms for the 288 models registered in the same heater type and draw pattern; it ranks 278 of 288, lowest energy first.

This model: 194 therms

Solid line: this model (194 therms). Dashed line: the class median.

Min 148 therms Median 185 therms Max 194 therms

DOE CCD · 2026-09-19

Report an issue with this number


What it costs to run where you live

Enter your ZIP to see what this unit costs to run a year at your state’s average natural gas price.


What the registry files

UEF (Uniform Energy Factor) how much hot water you get for each unit of energy the heater uses
0.57 DOE CCD · 2026-09-19 Compared only with other models registered as a gas tank at the medium draw pattern.
Draw Pattern the standard daily usage profile DOE tests the unit against
Medium DOE CCD · 2026-09-19
First Hour Rating how many gallons of hot water the unit can deliver in one hour, starting from a full tank
67 gal DOE CCD · 2026-09-19
Rated Storage Volume the tank size in gallons
47 gal DOE CCD · 2026-09-19

What it costs to install

Not published: Installed cost range

This model's UEF lies outside the range NLR REMDB's cost model was fitted on, and the range is not stretched past it.

The annual energy figure on this page does not depend on this range and is unaffected.


Safety record

No CPSC recall names this model.

Checked against the CPSC recall database. CPSC does not publish a model-level match for this product category, so this list is curated by hand from the manufacturer's recall filings.

CPSC · 2026-09-24

What these figures mean

The 194 therms figure is computed by this site. The registry does not publish it. It combines the registry's UEF, the ratio of hot water delivered to energy used, with the DOE test's daily hot-water draw for the medium pattern. For the FMDV-50 2**, the UEF is 0.57, as listed in the DOE CCD retrieved 2026-09-19. The yearly figure therefore holds only at the federal test's daily draw. A household that draws more hot water than the test assumes will use more gas than 194 therms, and one that draws less will use less. The registry does not report measured use in real homes, so field consumption for this model is not available. The steps from UEF to a yearly figure are set out in how the annual cost is calculated.

The FMDV-50 2** lists a first hour rating, the gallons of hot water available in the first hour from a full tank, of 67 gallons. Its rated volume is 47 gallons. These figures describe a unit tested against a typical household's busy-morning demand. It fits a reader whose peak use stays within 67 gallons in the first hour and who accepts gas use 9 therms above the class median. It fits less well where lower gas use is the aim. Ranked 278th lowest of 288, it uses more gas than most gas tank models at this pattern at the same test draw. A plumber or seller checking alternatives can find a same-class replacement by model number.

This page does not state a running cost in the text. The cost of 194 therms a year depends on the reader's state average residential gas price, so the page computes it from the reader's ZIP. The cost calculator on your own ZIP applies that rate to this model's yearly figure at the medium pattern. The result holds only at the federal test's daily draw, as noted above. An installed price range for the FMDV-50 2** is not published. Its ratings lie outside the range the cost database's model was fitted on. The site does not stretch that model past its fitted range, so no installed price is estimated here.

DOE CCD · 2026-09-19

How this compares

The closest models in the same class — same fuel, type and draw pattern.


Keep going