Ruud RTGH-84DVLN-3
0.93 UEF DOE CCD · 2026-09-19Grade C: where this UEF sits among the 397 models in its class, lowest (G) to highest (A). A position, not an official label. How the grade is set
A gas tankless unit, high draw pattern (a larger household, or one where showers and laundry overlap).
If you are verifying the Ruud RTGH-84DVLN-3, this gas tankless unit uses 182 therms of natural gas a year. That figure applies at the high draw pattern, the standard daily hot-water usage DOE tests against. It equals the class median of 182 therms, a difference of 0 therms, across 397 comparable models.
Energy use per year
182 therms a year
Computed by this site from the registry's UEF and the federal test's daily hot-water draw for this draw pattern. What it costs depends on the natural gas rate where you live.
That is equal to the median of 182 therms for the 397 models registered in the same heater type and draw pattern; it ranks 183 of 397, lowest energy first.
Solid line: this model (182 therms). Dashed line: the class median.
Min 173 therms Median 182 therms Max 209 therms
What it costs to run where you live
What the registry files
- UEF (Uniform Energy Factor) how much hot water you get for each unit of energy the heater uses
- 0.93 DOE CCD · 2026-09-19 Compared only with other models registered as a gas tankless unit at the high draw pattern.
- Draw Pattern the standard daily usage profile DOE tests the unit against
- High DOE CCD · 2026-09-19
- Maximum Gallons Per Minute how many gallons a minute it can heat while running continuously
- 4.5 gal/min DOE CCD · 2026-09-19
What it costs to install
$2,264–$3,294 installed
Not a quote — a modeled range of what installers have charged for this class of unit; your price will vary with labor rates, access, and local code requirements.
Escalation indexes: equipment (BLS PPI) latest available: August 2026; labor (BLS ECI) latest available: April 2026 to June 2026.
NLR REMDB (BLS PPI/ECI escalated) · 2026-04-01Safety record
No CPSC recall names this model.
Checked against the CPSC recall database. CPSC does not publish a model-level match for this product category, so this list is curated by hand from the manufacturer's recall filings.
CPSC · 2026-09-24What these figures mean
How this compares
The closest models in the same class — same fuel, type and draw pattern.
Keep going
How every figure on this page is calculated
-
Find what replaces your water heater
Enter the model number off your old unit and see what is on file today, with the yearly cost difference.
-
Find a water heater that fits
Three questions — fuel, hot water need, install space — narrow every model on file to the ones that fit.
-
What a water heater costs to run
Prices a unit's efficiency against your own utility's filed tariff for your ZIP code.
-
How to size a tankless water heater by GPM
Answered from what models in this size actually file.
-
Water heaters
Every model on file with the Department of Energy, by heater type.
-
All gas tankless water heaters
Gas-fired instantaneous units, sized by flow rate rather than tank gallons.
-
Every Ruud model on file
What this brand files, by heater type.
UEF 0.93 · Grade C Price it on your ZIP
The 182 therms figure is computed by this site, not published by the registry. It combines the registry's UEF, the ratio of hot water delivered to energy used, with the DOE test's daily hot-water draw. For the RTGH-84DVLN-3, the UEF is 0.93, and the draw used is the one set for the high draw pattern. The source is DOE's Compliance Certification Database (CCD), retrieved 2026-09-19. The figure therefore describes use under the federal test's conditions, not a measured bill from any home. A household drawing more or less hot water than the test assumes will use a different amount; that amount is not available here. The steps are set out in how this site calculates annual energy and cost.
The high draw pattern describes a larger household, or one where showers and laundry overlap. Among the 397 gas tankless models registered at that pattern, the RTGH-84DVLN-3 ranks 183rd lowest in energy use. That places it in the second-lowest quarter of its class. Its maximum flow rate in gallons per minute is 4.5. Whether that rate covers a particular set of fixtures running at once is not stated in the data. For a home that fits a lower draw pattern, the 182 therms figure does not apply, and no figure for other patterns is available on this page. To check a same-class model against this one, use the replacement finder by model number.
Running cost is not written here because it depends on your state's average residential gas price. The page computes it from your ZIP instead, using the 182 therms figure at the high draw pattern. You can run the same calculation in the cost calculator for your own ZIP. Because its use is 0 therms from the class median of 182 therms, its running cost at a given gas price matches a median model's. The installed price range appears in its own block, with its source and date. It is a modeled installed-cost range, not a quote, and its figures are not repeated here.
DOE CCD · 2026-09-19