Ruud PROP G40-50* RH HE EC3
0.9 UEF DOE CCD · 2026-09-19Grade A: where this UEF sits among the 414 models in its class, lowest (G) to highest (A). A position, not an official label. How the grade is set
A gas tank, high draw pattern (a larger household, or one where showers and laundry overlap).
Checking the Ruud PROP G40-50* RH HE EC3? This gas tank uses 188 therms of natural gas a year at the high draw pattern, the standard daily hot-water usage DOE tests against. That is 72 therms below the 260 therms median of the 414 gas tank models at that pattern. It ranks 1st lowest among them.
Energy use per year
188 therms a year
Computed by this site from the registry's UEF and the federal test's daily hot-water draw for this draw pattern. What it costs depends on the natural gas rate where you live.
That is below the median of 260 therms for the 414 models registered in the same heater type and draw pattern; it ranks 1 of 414, lowest energy first.
Solid line: this model (188 therms). Dashed line: the class median.
Min 188 therms Median 260 therms Max 277 therms
What it costs to run where you live
What the registry files
- UEF (Uniform Energy Factor) how much hot water you get for each unit of energy the heater uses
- 0.9 DOE CCD · 2026-09-19 Compared only with other models registered as a gas tank at the high draw pattern.
- Draw Pattern the standard daily usage profile DOE tests the unit against
- High DOE CCD · 2026-09-19
- First Hour Rating how many gallons of hot water the unit can deliver in one hour, starting from a full tank
- 88 gal DOE CCD · 2026-09-19
- Rated Storage Volume the tank size in gallons
- 40 gal DOE CCD · 2026-09-19
- On the market since (ENERGY STAR) the date the manufacturer told ENERGY STAR the model went on sale
- 2023-10-23 ENERGY STAR · 2026-09-19
- Connected / demand response (ENERGY STAR) whether the unit can take signals from your utility to shift when it heats, and by which standard (such as CTA-2045)
- No ENERGY STAR · 2026-09-19
What it costs to install
Not published: Installed cost range
This model's UEF lies outside the range NLR REMDB's cost model was fitted on, and the range is not stretched past it.
The annual energy figure on this page does not depend on this range and is unaffected.
Safety record
No CPSC recall names this model.
Checked against the CPSC recall database. CPSC does not publish a model-level match for this product category, so this list is curated by hand from the manufacturer's recall filings.
CPSC · 2026-09-24Does it fit your space?
Enter your own numbers below — this compares them to what ENERGY STAR publishes for this model, it does not tell you what to buy.
- Dimensions (ENERGY STAR)
- the unit's filed height, width, depth or tank diameter, in inches
- Input voltage and maximum current (ENERGY STAR)
- the circuit voltage the unit is certified on and the most current it draws
- Vent type and size (ENERGY STAR)
- how a gas unit is vented, the vent's diameter and the height of its vent connector
What these figures mean
How this compares
The closest models in the same class — same fuel, type and draw pattern.
Keep going
How every figure on this page is calculated
-
Find what replaces your water heater
Enter the model number off your old unit and see what is on file today, with the yearly cost difference.
-
Find a water heater that fits
Three questions — fuel, hot water need, install space — narrow every model on file to the ones that fit.
-
What a water heater costs to run
Prices a unit's efficiency against your own utility's filed tariff for your ZIP code.
-
Is a 40-gallon water heater enough?
Answered from what models in this size actually file.
-
Water heaters
Every model on file with the Department of Energy, by heater type.
-
All gas tank water heaters
Gas-fired storage tanks, every size and draw pattern on file.
-
Every Ruud model on file
What this brand files, by heater type.
UEF 0.9 · Grade A Price it on your ZIP
This site computes the 188 therms figure. The registry does not publish it. The figure combines this model's UEF, the ratio of hot water delivered to energy used, with the DOE test's daily hot-water draw for the high pattern. The registry lists a UEF of 0.9 for the PROP G40-50* RH HE EC3. The source data comes from the DOE CCD, retrieved 2026-09-19. The figure applies only at the test's daily draw. A household using more or less hot water than the test assumes will burn a different amount of gas. That amount is not available here. Among the 414 gas tank models at the high draw pattern, the 72 therms gap puts this unit in the lowest quarter for energy use.
The high draw pattern describes a larger household, or one where showers and laundry overlap. The registry lists this unit's first hour rating, the gallons of hot water available in the first hour from a full tank, at 88 gallons. Its rated volume is 40 gallons. The 188 therms figure assumes the high pattern's daily draw, so it does not describe a smaller household's use. Models registered at a different draw pattern are not part of this class of 414. Their energy figures do not compare like for like with this one. To compare models across classes, use the water heater selector by fuel, space and size. To stay within this class, try the same-class replacement search by model number.
This text does not state the running cost. The cost depends on your state's average residential gas price, so the page calculates it from your ZIP. You can see that cost for the 188 therms figure with the water heater cost calculator for your ZIP. Your rate also sets the value of the 72 therms gap to the class median. The steps behind the calculation are described in how the annual water heater cost is calculated. No installed price range is published for this model. Its ratings fall outside the range the cost database's model was fitted on. The page does not extend that range to cover them, so the installed price is unknown here.
DOE CCD · 2026-09-19