DoesTheMath

Ruud PROE50 T2 RH95

0.93 UEF DOE CCD · 2026-09-19
G

Grade G: where this UEF sits among the 426 models in its class, lowest (G) to highest (A). A position, not an official label. How the grade is set

An electric tank, medium draw pattern (a typical three- or four-person household, about 55 gallons on a busy morning).

Checking the Ruud PROE50 T2 RH95? At the medium draw pattern, the standard daily hot-water usage DOE tests against, this electric tank uses 3,493 kWh of electricity a year. That is 38 kWh below its class median of 3,531 kWh. It ranks 153rd lowest in energy use of 426 models.


Energy use per year

3,493 kWh a year

Computed by this site from the registry's UEF and the federal test's daily hot-water draw for this draw pattern. What it costs depends on the electricity rate where you live.

That is below the median of 3,531 kWh for the 426 models registered in the same heater type and draw pattern; it ranks 153 of 426, lowest energy first.

This model: 3,493 kWh

Solid line: this model (3,493 kWh). Dashed line: the class median.

Min 773 kWh Median 3,531 kWh Max 3,569 kWh

DOE CCD · 2026-09-19

Report an issue with this number


What it costs to run where you live

Enter your ZIP to see what this unit costs to run a year on your own utility’s electricity rate.


What the registry files

UEF (Uniform Energy Factor) how much hot water you get for each unit of energy the heater uses
0.93 DOE CCD · 2026-09-19 Compared only with other models registered as an electric tank at the medium draw pattern.
Draw Pattern the standard daily usage profile DOE tests the unit against
Medium DOE CCD · 2026-09-19
First Hour Rating how many gallons of hot water the unit can deliver in one hour, starting from a full tank
63 gal DOE CCD · 2026-09-19
Rated Storage Volume the tank size in gallons
45 gal DOE CCD · 2026-09-19

What it costs to install

$1,728–$2,244 installed

Not a quote — a modeled range of what installers have charged for this class of unit; your price will vary with labor rates, access, and local code requirements.

Escalation indexes: equipment (BLS PPI) latest available: August 2026; labor (BLS ECI) latest available: April 2026 to June 2026.

NLR REMDB (BLS PPI/ECI escalated) · 2026-04-01

Report an issue with this number


Safety record

No CPSC recall names this model.

Checked against the CPSC recall database. CPSC does not publish a model-level match for this product category, so this list is curated by hand from the manufacturer's recall filings.

CPSC · 2026-09-24

What these figures mean

This site calculates the 3,493 kWh total; the registry does not list it. The calculation combines the registry's UEF, the ratio of hot water delivered to energy used, with the DOE test's daily hot-water draw for the medium pattern. The UEF on record for this model is 0.93, from the DOE CCD, retrieved 2026-09-19. The test sets a fixed draw, so the total applies only at that draw. A household that uses more or less hot water each day will see a different total. The class comparison uses the same condition: the 426 models registered as an electric tank at the medium draw pattern. The median among them is 3,531 kWh, and this model sits 38 kWh below it. The steps are set out in how the annual cost is calculated.

The medium draw pattern represents a typical household of several people on a busy morning. The tank's rated volume is 45 gallons. Its first hour rating, the gallons of hot water available in the first hour from a full tank, is 63 gallons. A household whose morning peak stays within 63 gallons matches the condition behind the 3,493 kWh figure. A household with a larger peak falls outside that condition. So does a household that needs a gas unit instead of an electric tank. The rank of 153rd lowest of 426 applies only within this class of medium-pattern electric tanks. It says nothing about models in other classes. To compare units by fuel, space and size, use the water heater selector by fuel, space and size.

The text on this page gives no running cost. The cost of 3,493 kWh a year depends on the electricity tariff of your own utility. The page computes that cost from your ZIP, using the same 3,493 kWh at the medium draw pattern. The cost calculator for your own ZIP shows the figure at your rate. On the same tariff, this model's cost gap from a median unit follows its energy gap of 38 kWh. The installed price range appears in a separate block on this page, with its source and date. It is a modeled installed-cost range, not a quote. If you need a replacement in the same class, you can find a same-class replacement by model number.

DOE CCD · 2026-09-19

How this compares

The closest models in the same class — same fuel, type and draw pattern.


Keep going

UEF 0.93 · Grade G Price it on your ZIP