Ruud PROE40 T2 RH95

0.93 UEF DOE CCD · 2026-09-19
G

Grade G: where this UEF sits among the 426 models in its class, lowest (G) to highest (A). A position, not an official label. How the grade is set

An electric tank, medium draw pattern (a typical three- or four-person household, about 55 gallons on a busy morning).

If you are checking the Ruud PROE40 T2 RH95, it uses 3,493 kWh of electricity a year at the medium draw pattern, the standard daily hot-water usage DOE tests against. That is 38 kWh below the 3,531 kWh median of the 426 electric tank models registered at the same draw pattern.


Energy use per year

3,493 kWh a year

Computed by this site from the registry's UEF and the federal test's daily hot-water draw for this draw pattern. What it costs depends on the electricity rate where you live.

That is below the median of 3,531 kWh for the 426 models registered in the same heater type and draw pattern; it ranks 153 of 426, lowest energy first.

This model: 3,493 kWh

Solid line: this model (3,493 kWh). Dashed line: the class median.

Min 773 kWh Median 3,531 kWh Max 3,569 kWh

DOE CCD · 2026-09-19

Report an issue with this number


What it costs to run where you live

Enter your ZIP to see what this unit costs to run a year on your own utility’s electricity rate.


What the registry files

UEF (Uniform Energy Factor) how much hot water you get for each unit of energy the heater uses
0.93 DOE CCD · 2026-09-19 Compared only with other models registered as an electric tank at the medium draw pattern.
Draw Pattern the standard daily usage profile DOE tests the unit against
Medium DOE CCD · 2026-09-19
First Hour Rating how many gallons of hot water the unit can deliver in one hour, starting from a full tank
55 gal DOE CCD · 2026-09-19
Rated Storage Volume the tank size in gallons
36 gal DOE CCD · 2026-09-19

What it costs to install

$1,597–$2,019 installed

Not a quote — a modeled range of what installers have charged for this class of unit; your price will vary with labor rates, access, and local code requirements.

Escalation indexes: equipment (BLS PPI) latest available: August 2026; labor (BLS ECI) latest available: April 2026 to June 2026.

NLR REMDB (BLS PPI/ECI escalated) · 2026-04-01

Report an issue with this number


Safety record

No CPSC recall names this model.

Checked against the CPSC recall database. CPSC does not publish a model-level match for this product category, so this list is curated by hand from the manufacturer's recall filings.

CPSC · 2026-09-24

What these figures mean

The registry does not print the 3,493 kWh figure. This site computed it from the registry's UEF, the ratio of hot water delivered to energy used, and the DOE test's daily hot-water draw for the medium draw pattern. For this model the UEF is 0.93, and the source is the DOE CCD, retrieved 2026-09-19. Among the 426 electric tank models at the medium draw pattern, it ranks 153rd lowest for energy use. That puts it in the second-lowest quarter of its class. The gap to the class median of 3,531 kWh is 38 kWh a year, measured at the test's draw. The figure holds only at that draw. At a different daily draw it would change, and this page does not have data on how much.

The PROE40 T2 RH95 has a rated volume of 36 gallons. Its first hour rating, the gallons of hot water available in the first hour from a full tank, is 55 gallons. The medium draw pattern represents a typical mid-sized household on a busy morning. So the 3,493 kWh figure describes homes whose use is close to that assumption. A household whose morning peak regularly goes above 55 gallons falls outside the conditions behind this figure. The registry data here does not give this model's energy use for that case. To compare units of other sizes or fuels, use the water heater selector by fuel, space and size. To check another unit in the same class, find a same-class replacement by model number.

This text does not state a running cost, because the cost depends on your own utility's electricity tariff. The page calculates it from your ZIP rather than estimating it. The input is 3,493 kWh a year at the medium draw pattern, combined with your rate. The 38 kWh gap to the class median becomes a cost difference only at your tariff, and that amount is not given in this text. The cost calculator for your own ZIP applies your rate, and how the annual cost is calculated lists each step. The installed-price range on this page appears in its own block, with its own source and date. It is a modeled range, not a quote.

DOE CCD · 2026-09-19

How this compares

The closest models in the same class — same fuel, type and draw pattern.


Keep going

UEF 0.93 · Grade G Price it on your ZIP