Richmond PROG50S-36N RH67 PV
0.7 UEF DOE CCD · 2026-09-19Grade E: where this UEF sits among the 414 models in its class, lowest (G) to highest (A). A position, not an official label. How the grade is set
A gas tank, high draw pattern (a larger household, or one where showers and laundry overlap).
If you are checking the Richmond PROG50S-36N RH67 PV, it uses 242 therms of natural gas a year at the high draw pattern, the standard daily hot-water usage DOE tests against. That figure sits 18 therms below the 260 therms median of the 414 gas tank models registered at the same pattern, where it ranks 90th lowest.
Energy use per year
242 therms a year
Computed by this site from the registry's UEF and the federal test's daily hot-water draw for this draw pattern. What it costs depends on the natural gas rate where you live.
That is below the median of 260 therms for the 414 models registered in the same heater type and draw pattern; it ranks 90 of 414, lowest energy first.
Solid line: this model (242 therms). Dashed line: the class median.
Min 188 therms Median 260 therms Max 277 therms
What it costs to run where you live
What the registry files
- UEF (Uniform Energy Factor) how much hot water you get for each unit of energy the heater uses
- 0.7 DOE CCD · 2026-09-19 Compared only with other models registered as a gas tank at the high draw pattern.
- Draw Pattern the standard daily usage profile DOE tests the unit against
- High DOE CCD · 2026-09-19
- First Hour Rating how many gallons of hot water the unit can deliver in one hour, starting from a full tank
- 78 gal DOE CCD · 2026-09-19
- Rated Storage Volume the tank size in gallons
- 48 gal DOE CCD · 2026-09-19
What it costs to install
$2,141–$4,033 installed
Not a quote — a modeled range of what installers have charged for this class of unit; your price will vary with labor rates, access, and local code requirements.
Escalation indexes: equipment (BLS PPI) latest available: August 2026; labor (BLS ECI) latest available: April 2026 to June 2026.
NLR REMDB (BLS PPI/ECI escalated) · 2026-04-01Safety record
No CPSC recall names this model.
Checked against the CPSC recall database. CPSC does not publish a model-level match for this product category, so this list is curated by hand from the manufacturer's recall filings.
CPSC · 2026-09-24What these figures mean
How this compares
The closest models in the same class — same fuel, type and draw pattern.
Keep going
How every figure on this page is calculated
-
Find what replaces your water heater
Enter the model number off your old unit and see what is on file today, with the yearly cost difference.
-
Find a water heater that fits
Three questions — fuel, hot water need, install space — narrow every model on file to the ones that fit.
-
What a water heater costs to run
Prices a unit's efficiency against your own utility's filed tariff for your ZIP code.
-
Is a 50-gallon water heater enough?
Answered from what models in this size actually file.
-
Water heaters
Every model on file with the Department of Energy, by heater type.
-
All gas tank water heaters
Gas-fired storage tanks, every size and draw pattern on file.
-
Every Richmond model on file
What this brand files, by heater type.
UEF 0.7 · Grade E Price it on your ZIP
The 242 therms figure is computed by this site, not taken from the registry. It combines the registry's UEF, the ratio of hot water delivered to energy used, with the DOE test's daily hot-water draw for the high pattern. For this model, the UEF is 0.7. The source is DOE's Compliance Certification Database, retrieved 2026-09-19. Because the figure assumes the federal test's daily draw, it holds only at that draw. A household using a different amount of hot water will use a different amount of gas, and that amount is not available here. Within its class, this model sits in the lowest quarter for energy use. The steps behind the figure are set out in how the annual cost is calculated.
The high draw pattern describes a larger household, or one where showers and laundry overlap. This model's first hour rating, the gallons of hot water available in the first hour from a full tank, is 78 gallons. Its rated volume is 48 gallons. A home whose daily use matches the high pattern is the case the 242 therms figure describes. A smaller household drawing less hot water each day sits outside that test condition. The registry gives no energy figure for this model at a lower draw, so that use is unknown. The class comparison also covers only gas tanks tested at the high pattern. Other gas tanks at that pattern can be checked with a same-class replacement search by model number.
The running cost is not stated in this text. It depends on the average residential gas price in the reader's state, so the page computes it from the reader's ZIP. The input for that calculation is the 242 therms figure at the high draw pattern. The 18 therms gap to the class median becomes a cost gap only once a gas price is applied. The cost calculator on your own ZIP applies your state's rate to this model's energy use. The installed price range appears in its own block on this page, with its source and date. That range is a modeled installed-cost range for this class, not a quote for this PROG50S-36N RH67 PV unit.
DOE CCD · 2026-09-19