DoesTheMath

Rheem SPEX60T

0.97 UEF DOE CCD · 2026-09-19
E

Grade E: where this UEF sits among the 271 models in its class, lowest (G) to highest (A). A position, not an official label. How the grade is set

An electric tankless unit, very small draw pattern (small units - a single bathroom, or a point-of-use heater under a sink).

If you are checking the Rheem SPEX60T, an electric tankless unit, it uses 609 kWh of electricity a year. That figure applies at the federal test's daily hot-water draw for the very small draw pattern, the standard daily hot-water usage DOE tests against. It is 6 kWh below its class median of 615 kWh.


Energy use per year

609 kWh a year

Computed by this site from the registry's UEF and the federal test's daily hot-water draw for this draw pattern. What it costs depends on the electricity rate where you live.

That is below the median of 615 kWh for the 271 models registered in the same heater type and draw pattern; it ranks 37 of 271, lowest energy first.

This model: 609 kWh

Solid line: this model (609 kWh). Dashed line: the class median.

Min 562 kWh Median 615 kWh Max 649 kWh

DOE CCD · 2026-09-19

Report an issue with this number


What it costs to run where you live

Enter your ZIP to see what this unit costs to run a year on your own utility’s electricity rate.


What the registry files

UEF (Uniform Energy Factor) how much hot water you get for each unit of energy the heater uses
0.97 DOE CCD · 2026-09-19 Compared only with other models registered as an electric tankless unit at the very small draw pattern.
Draw Pattern the standard daily usage profile DOE tests the unit against
Very small DOE CCD · 2026-09-19
Maximum Gallons Per Minute how many gallons a minute it can heat while running continuously
0.6 gal/min DOE CCD · 2026-09-19

What it costs to install

$1,309–$1,862 installed

Not a quote — a modeled range of what installers have charged for this class of unit; your price will vary with labor rates, access, and local code requirements.

Escalation indexes: equipment (BLS PPI) latest available: August 2026; labor (BLS ECI) latest available: April 2026 to June 2026.

NLR REMDB (BLS PPI/ECI escalated) · 2026-04-01

Report an issue with this number


Safety record

No CPSC recall names this model.

Checked against the CPSC recall database. CPSC does not publish a model-level match for this product category, so this list is curated by hand from the manufacturer's recall filings.

CPSC · 2026-09-24

What these figures mean

This site calculated the 609 kWh figure; the registry does not publish it. The calculation uses the registry's UEF, the ratio of hot water delivered to energy used, and the DOE test's daily hot-water draw for the very small pattern. The UEF for this model is 0.97. Both inputs come from DOE's Compliance Certification Database (CCD), retrieved 2026-09-19. The figure only describes use under test conditions. A household that uses more hot water each day than the test assumes will use more than 609 kWh. The registry does not say how much more. For each step, see how the annual energy and cost figures are calculated.

The class for this model is the 271 models registered as an electric tankless unit at the very small draw pattern. It ranks 37th lowest for energy use in that class. The very small pattern covers small units, meaning a single bathroom or a point-of-use heater under a sink. The registry lists a maximum flow rate in gallons per minute of 0.6 for this model. The registry figures describe that single-bathroom or under-sink load and do not describe a whole-house load. The registry does not say how the unit performs with several fixtures running at once. For a larger load, the selector by fuel, space and size lists other classes.

The running cost is not stated in the text because it depends on your own utility's electricity tariff. The page calculates it from your ZIP, using 609 kWh as the energy input. You can run the same calculation in the running-cost calculator for your ZIP. Compared with a median model in the same class, the cost gap at your rate comes from the 6 kWh difference noted above. It does not come from the whole 609 kWh. The installed price range has its own block, with its source and date. That range is modeled and is not a quote. To match a unit in the same class, find a same-class replacement by model number.

DOE CCD · 2026-09-19

How this compares

The closest models in the same class — same fuel, type and draw pattern.


Keep going

UEF 0.97 · Grade E Price it on your ZIP