DoesTheMath

Rheem SPEX3012T

0.96 UEF DOE CCD · 2026-09-19
E

Grade E: where this UEF sits among the 271 models in its class, lowest (G) to highest (A). A position, not an official label. How the grade is set

An electric tankless unit, very small draw pattern (small units - a single bathroom, or a point-of-use heater under a sink).

If you are checking the Rheem SPEX3012T, it uses 615 kWh of electricity a year at the federal test's daily hot-water draw. That figure belongs to the very small draw pattern, the standard daily hot-water usage DOE tests against. It equals its class median of 615 kWh, a difference of 0 kWh, and ranks 77th lowest of 271.


Energy use per year

615 kWh a year

Computed by this site from the registry's UEF and the federal test's daily hot-water draw for this draw pattern. What it costs depends on the electricity rate where you live.

That is equal to the median of 615 kWh for the 271 models registered in the same heater type and draw pattern; it ranks 77 of 271, lowest energy first.

This model: 615 kWh

Solid line: this model (615 kWh). Dashed line: the class median.

Min 562 kWh Median 615 kWh Max 649 kWh

DOE CCD · 2026-09-19

Report an issue with this number


What it costs to run where you live

Enter your ZIP to see what this unit costs to run a year on your own utility’s electricity rate.


What the registry files

UEF (Uniform Energy Factor) how much hot water you get for each unit of energy the heater uses
0.96 DOE CCD · 2026-09-19 Compared only with other models registered as an electric tankless unit at the very small draw pattern.
Draw Pattern the standard daily usage profile DOE tests the unit against
Very small DOE CCD · 2026-09-19
Maximum Gallons Per Minute how many gallons a minute it can heat while running continuously
0.3 gal/min DOE CCD · 2026-09-19

What it costs to install

$1,306–$1,838 installed

Not a quote — a modeled range of what installers have charged for this class of unit; your price will vary with labor rates, access, and local code requirements.

Escalation indexes: equipment (BLS PPI) latest available: August 2026; labor (BLS ECI) latest available: April 2026 to June 2026.

NLR REMDB (BLS PPI/ECI escalated) · 2026-04-01

Report an issue with this number


Safety record

No CPSC recall names this model.

Checked against the CPSC recall database. CPSC does not publish a model-level match for this product category, so this list is curated by hand from the manufacturer's recall filings.

CPSC · 2026-09-24

What these figures mean

This site calculates the 615 kWh figure. The registry does not publish it. The inputs are the registry's UEF, the ratio of hot water delivered to energy used, and the DOE test's daily hot-water draw for this draw pattern. For the SPEX3012T, the UEF is 0.96. The comparison class is the 271 models registered as an electric tankless unit at the very small draw pattern. As stated above, this model matches that class median. At 77th lowest, it is in the second-lowest quarter of the class for energy use. The value applies only at the federal test's draw. No figure is available for any other daily draw. The source is DOE CCD, retrieved 2026-09-19. The page also explains how the annual energy and cost are calculated.

The very small draw pattern covers small units: a single bathroom, or a point-of-use heater under a sink. The registry lists this model's maximum flow rate in gallons per minute as 0.3. Both values come from the same DOE CCD record. The 615 kWh figure does not describe a unit that serves loads outside this draw pattern. The registry gives no energy value for that kind of use. If you need hot water for more than a single bathroom or sink, the selector by fuel, space and size covers other classes. To compare this unit with another of the 271 models in its class, use same-class replacement by model number.

This text gives no running cost. The cost depends on your own utility electricity tariff, and the registry data does not include tariffs. It equals 615 kWh of electricity a year, at the very small draw pattern's test draw, multiplied by your rate. The cost calculator for your own ZIP does that multiplication with your local tariff. This model's energy use equals the class median of 615 kWh, so on any tariff its running cost matches that of a class-median unit. The installed price range has its own block on this page, with its source and date. That range is a modeled installed cost, not a quote.

DOE CCD · 2026-09-19

How this compares

The closest models in the same class — same fuel, type and draw pattern.


Keep going