RHEEM/RUUD PROE50 T2 RH95
0.93 UEF DOE CCD · 2026-09-19Grade G: where this UEF sits among the 426 models in its class, lowest (G) to highest (A). A position, not an official label. How the grade is set
An electric tank, medium draw pattern (a typical three- or four-person household, about 55 gallons on a busy morning).
If you are checking the RHEEM/RUUD PROE50 T2 RH95, this site computes 3,493 kWh of electricity a year at the medium draw pattern, the standard daily hot-water usage DOE tests against. At that draw pattern, that is 38 kWh below the 3,531 kWh median of the 426 electric tank models registered, ranking 153rd lowest.
Energy use per year
3,493 kWh a year
Computed by this site from the registry's UEF and the federal test's daily hot-water draw for this draw pattern. What it costs depends on the electricity rate where you live.
That is below the median of 3,531 kWh for the 426 models registered in the same heater type and draw pattern; it ranks 153 of 426, lowest energy first.
Solid line: this model (3,493 kWh). Dashed line: the class median.
Min 773 kWh Median 3,531 kWh Max 3,569 kWh
What it costs to run where you live
What the registry files
- UEF (Uniform Energy Factor) how much hot water you get for each unit of energy the heater uses
- 0.93 DOE CCD · 2026-09-19 Compared only with other models registered as an electric tank at the medium draw pattern.
- Draw Pattern the standard daily usage profile DOE tests the unit against
- Medium DOE CCD · 2026-09-19
- First Hour Rating how many gallons of hot water the unit can deliver in one hour, starting from a full tank
- 63 gal DOE CCD · 2026-09-19
- Rated Storage Volume the tank size in gallons
- 45 gal DOE CCD · 2026-09-19
What it costs to install
$1,728–$2,244 installed
Not a quote — a modeled range of what installers have charged for this class of unit; your price will vary with labor rates, access, and local code requirements.
Escalation indexes: equipment (BLS PPI) latest available: August 2026; labor (BLS ECI) latest available: April 2026 to June 2026.
NLR REMDB (BLS PPI/ECI escalated) · 2026-04-01Safety record
No CPSC recall names this model.
Checked against the CPSC recall database. CPSC does not publish a model-level match for this product category, so this list is curated by hand from the manufacturer's recall filings.
CPSC · 2026-09-24What these figures mean
How this compares
The closest models in the same class — same fuel, type and draw pattern.
Keep going
How every figure on this page is calculated
-
Find what replaces your water heater
Enter the model number off your old unit and see what is on file today, with the yearly cost difference.
-
Find a water heater that fits
Three questions — fuel, hot water need, install space — narrow every model on file to the ones that fit.
-
What a water heater costs to run
Prices a unit's efficiency against your own utility's filed tariff for your ZIP code.
-
Is a 40-gallon water heater enough?
Answered from what models in this size actually file.
-
Water heaters
Every model on file with the Department of Energy, by heater type.
-
All electric resistance tank water heaters
Electric tanks that file a UEF below 2.0 — heated by elements, not a heat pump.
-
Every RHEEM/RUUD model on file
What this brand files, by heater type.
UEF 0.93 · Grade G Price it on your ZIP
The 3,493 kWh figure is not a registry value. This site computed it from the registry's UEF, the ratio of hot water delivered to energy used, and the DOE test's daily hot-water draw for the medium draw pattern. For this model the registry lists a UEF of 0.93, taken from DOE CCD data retrieved 2026-09-19. The figure holds only at that test draw. A household using more or less hot water each day will use a different amount, and this page cannot say how much. At the test draw, the model sits 38 kWh below the class median of 3,531 kWh. That places it 153rd lowest for energy use among 426 electric tank models at the medium draw pattern. The steps behind the numbers are set out in how the annual cost is calculated.
The 3,493 kWh figure fits a household whose daily hot-water use is close to the medium draw pattern. DOE uses that pattern to stand for a typical mid-sized household on a busy morning. The registry gives this model a first hour rating, the gallons of hot water available in the first hour from a full tank, of 63 gallons. Its rated volume is 45 gallons. A home that needs more than 63 gallons in its first busy hour is outside what that rating covers. The registry does not report how the model performs above or below the medium draw, so that is unknown here. To compare against other models in the same class of 426, use the same-class replacement search by model number.
This page gives no running cost in the text. The yearly cost of 3,493 kWh of electricity depends on the reader's own utility electricity tariff. The page therefore computes it from the reader's ZIP rather than estimating it here. The cost calculator for your own ZIP applies your rate to the same medium-draw figure. At any single tariff, the 38 kWh gap to the 3,531 kWh class median carries into cost in proportion to that rate. The installed price range appears in its own block with its source and date. It is a modeled installed-cost range, not a quote, and it is separate from the running-cost calculation.
DOE CCD · 2026-09-19