Rheem PROPH65 T2 RH400-15
915 kWh a year DOE CCD (opens in a new tab) (the U.S. Department of Energy’s Compliance Certification Database) · 2026-10-25UEF 3.55 filed efficiency; the yearly figure is computed from it
Grade B: where this UEF sits among the 452 models in its class, lowest (G) to highest (A). A position, not an official label. How the grade is set
A heat pump water heater (filed by DOE as an electric tank, UEF 2.0 and up), medium draw pattern (a typical three- or four-person household, about 55 gallons on a busy morning).
Label numbers this filing covers (1)
The model number on your rating plate may be any of these; each is filed under this one listing.
- XE65T10H22U0
You are checking the energy figure for the Rheem PROPH65 T2 RH400-15. It uses 915 kWh a year at the medium draw pattern, the standard daily hot-water usage DOE tests against. That is 2,578 kWh below the class median of 3,493 kWh across 452 electric tank models.
Energy use per year
915 kWh a year
Computed by this site from the registry's UEF and the federal test's daily hot-water draw for this draw pattern. What it costs depends on the electricity rate where you live.
This model is in the lowest quarter of its class for energy use. That is below the median of 3,493 kWh for the 452 models registered in the same heater type and draw pattern; it ranks 74 of 452, lowest energy first.
Among the 153 heat pump water heaters at this draw pattern alone, it ranks 74 by lowest yearly energy.
This model 915 kWh
Median 3,493 kWh
Min 773 kWh Max 3,569 kWh
What it costs to run where you live
What the registry files
From DOE CCD · 2026-10-25
- UEF (Uniform Energy Factor) how much hot water you get for each unit of energy the heater uses
- 3.55 Compared only with other models registered as an electric tank at the medium draw pattern.
- Draw Pattern the standard daily usage profile DOE tests the unit against
- Medium
- First Hour Rating how many gallons of hot water the unit can deliver in one hour, starting from a full tank
- 54 gal
- Rated Storage Volume the tank size in gallons
- 59 gal Rated volume is the size the registry files. The number in a model name is the maker's nominal size and can differ: a "40-gallon" model may be rated at 36.
From ENERGY STAR · 2026-10-25
- On the market since (ENERGY STAR) the date the manufacturer told ENERGY STAR the model went on sale
- 2024-06-24
- Connected / demand response (ENERGY STAR) whether the unit can take signals from your utility to shift when it heats, and by which standard (such as CTA-2045)
- Yes (CTA-2045-B)
- Refrigerant and GWP (ENERGY STAR) the refrigerant a heat pump unit uses and its global warming potential, a leak's climate effect relative to carbon dioxide (CO2 = 1)
- R-134a, GWP 1430
Installed cost and service life
$3,475–$4,360 installed
Not a quote — a modeled range of what installers have charged for this class of unit; your price will vary with labor rates, access, and local code requirements.
Brought to current prices with Bureau of Labor Statistics indexes: equipment to May 2026, installation labor to April 2026–June 2026.
NLR REMDB (BLS PPI/ECI escalated) · 2026-04-01Service life: DOE’s cost database assumes 14.8 years for heat pump tanks. That is a class assumption, not this model’s rating or a warranty — no registry publishes either.
NLR REMDB v4.0.0 · 2026-09-07Rebates this model qualifies for
- Efficiency Arizona, Arizona: last checked 2026-10-21; confirm on the program's page
- Home Electrification and Appliance Rebates (HEAR), Colorado: not paying now
- High-Efficiency Electric Home Rebates (HEEHR), Florida: not paying now
- Home Electrification and Appliance Rebates (HEAR), Georgia: not paying now
- Home Electrification and Appliance Rebate (HEAR), Texas: not paying now
- Home Appliance Rebate Program (HARP), Washington: not paying now
This model meets each program's model rules. Your household's own rules (income, what it replaces) are on each state page. Every state program on file.
Safety record
No CPSC recall names this model.
Checked against the CPSC recall database. CPSC does not publish a model-level match for this product category, so this list is curated by hand from the manufacturer's recall filings.
CPSC · 2026-09-24Does it fit your space?
Enter your own numbers below — this compares them to what ENERGY STAR publishes for this model, it does not tell you what to buy.
- Compressor operating range (ENERGY STAR)
- the air temperatures around the unit in which its heat pump runs; outside this range the heat pump stops
- Dimensions (ENERGY STAR)
- the unit's filed height, width, depth or tank diameter, in inches
- Input voltage and maximum current (ENERGY STAR)
- the circuit voltage the unit is certified on and the most current it draws
What these figures mean
How this compares
The closest models in the same class — same fuel, type and draw pattern — that have their own comparison page.
Keep going
How every figure on this page is calculated
-
Find what replaces your water heater
Enter the model number off your old unit and see what is on file today, with the yearly cost difference.
-
Find a water heater that fits
Three questions — fuel, hot water need, install space — narrow every model on file to the ones that fit.
-
What a water heater costs to run
Prices a unit's efficiency against your own utility's filed tariff for your ZIP code.
-
What size heat pump water heater do I need?
Answered from what models in this size actually file.
-
Clothes washers
What a washer uses in a year, including the hot water it draws.
-
Every Rheem model on file
What this brand files, by heater type.
915 kWh/yr Grade B Cost on your ZIP
The annual figure of 915 kWh is computed by this site, not by the registry. It starts from the registry's UEF, the ratio of hot water delivered to energy used. It then applies the daily hot-water draw that the DOE test sets for this draw pattern. This model's UEF is 3.55. The data source is DOE CCD, retrieved 2026-10-25. The calculation method for the annual cost is documented separately. A household that draws more or less hot water than the test assumes will use a different amount. This page does not estimate that amount.
Among 452 electric tank models registered at the medium draw pattern, this model has the 74th lowest energy use. That places it in the lowest quarter of its class. The first hour rating, the gallons of hot water available in the first hour from a full tank, is 54 gallons. The rated volume is 59 gallons. The energy figure suits a household whose demand is close to the test's medium draw pattern. It says nothing about whether the tank covers a larger peak demand. The first hour rating is the figure to check for that. If you need to filter by fuel, space and size, use the water heater selector.
Read the rest
The running cost is not stated in the text, because it depends on your own utility electricity tariff. To check it, multiply 915 kWh by your rate per kWh, or use the cost calculator that takes your own ZIP. The 2,578 kWh gap to the class median is also a yearly figure at the medium draw pattern, so the same rate converts it into a cost difference. The modeled installed-cost range sits in its own block with its source and date. It is a modeled range, not a quote. To compare this model with others of its class, find a same-class replacement by model number.