DoesTheMath
Menu

Rheem PROPH65 T2 RH375-SO

1,225 kWh a year DOE CCD (opens in a new tab) (the U.S. Department of Energy’s Compliance Certification Database) · 2026-10-25

UEF 4.05 filed efficiency; the yearly figure is computed from it

B
  1. G at least 0.93
  2. F at least 1.5
  3. E at least 2.08
  4. D at least 2.65
  5. C at least 3.23
  6. B at least 3.8 , this model's grade
  7. A at least 4.38

Grade B: where this UEF sits among the 204 models in its class, lowest (G) to highest (A). A position, not an official label. How the grade is set

A heat pump water heater (filed by DOE as an electric tank, UEF 2.0 and up), high draw pattern (a larger household, or one where showers and laundry overlap).

Label numbers this filing covers (8)

The model number on your rating plate may be any of these; each is filed under this one listing.

  • CPROPH65 T2 RH375-SO
  • CPROPH65 T2 RH400-30
  • CPROPH65 T2 RH400-SO
  • CXE65T10H45U1
  • CXE65T10HS45U1
  • ECEPH65 T2 RH400-30
  • ECEPH65 T2 RH400-SO
  • PROPH65 T2 RH400-30

If you are checking this unit against the registry, the Rheem PROPH65 T2 RH375-SO uses 1,225 kWh of electricity a year at the high draw pattern, the standard daily hot-water usage DOE tests against. That is 81 kWh below the class median of 1,306 kWh for 204 electric tank models.


Energy use per year

1,225 kWh a year

Computed by this site from the registry's UEF and the federal test's daily hot-water draw for this draw pattern. What it costs depends on the electricity rate where you live.

This model is in the lowest quarter of its class for energy use. That is below the median of 1,306 kWh for the 204 models registered in the same heater type and draw pattern; it ranks 22 of 204, lowest energy first.

Among the 181 heat pump water heaters at this draw pattern alone, it ranks 22 by lowest yearly energy.

This model 1,225 kWh

This model: 1,225 kWh

Median 1,306 kWh

Min 1,002 kWh Max 5,334 kWh

DOE CCD (opens in a new tab) · 2026-10-25

Report an issue with this number


What it costs to run where you live

Enter your ZIP to see what this unit costs to run a year on your own utility’s electricity rate.


What the registry files

From DOE CCD · 2026-10-25

UEF (Uniform Energy Factor) how much hot water you get for each unit of energy the heater uses
4.05 Compared only with other models registered as an electric tank at the high draw pattern.
Draw Pattern the standard daily usage profile DOE tests the unit against
High
First Hour Rating how many gallons of hot water the unit can deliver in one hour, starting from a full tank
75 gal
Rated Storage Volume the tank size in gallons
59 gal Rated volume is the size the registry files. The number in a model name is the maker's nominal size and can differ: a "40-gallon" model may be rated at 36.

From ENERGY STAR · 2026-10-25

On the market since (ENERGY STAR) the date the manufacturer told ENERGY STAR the model went on sale
2022-12-05
Connected / demand response (ENERGY STAR) whether the unit can take signals from your utility to shift when it heats, and by which standard (such as CTA-2045)
Yes (CTA-2045-B)
Refrigerant and GWP (ENERGY STAR) the refrigerant a heat pump unit uses and its global warming potential, a leak's climate effect relative to carbon dioxide (CO2 = 1)
R-134a, GWP 1430

Installed cost and service life

$3,533–$4,864 installed

Not a quote — a modeled range of what installers have charged for this class of unit; your price will vary with labor rates, access, and local code requirements.

Brought to current prices with Bureau of Labor Statistics indexes: equipment to May 2026, installation labor to April 2026–June 2026.

NLR REMDB (BLS PPI/ECI escalated) · 2026-04-01

Report an issue with this number

Service life: DOE’s cost database assumes 14.8 years for heat pump tanks. That is a class assumption, not this model’s rating or a warranty — no registry publishes either.

NLR REMDB v4.0.0 · 2026-09-07

Rebates this model qualifies for

This model meets each program's model rules. Your household's own rules (income, what it replaces) are on each state page. Every state program on file.


Safety record

No CPSC recall names this model.

Checked against the CPSC recall database. CPSC does not publish a model-level match for this product category, so this list is curated by hand from the manufacturer's recall filings.

CPSC · 2026-09-24

Does it fit your space?

Enter your own numbers below — this compares them to what ENERGY STAR publishes for this model, it does not tell you what to buy.

Compressor operating range (ENERGY STAR)
the air temperatures around the unit in which its heat pump runs; outside this range the heat pump stops
Dimensions (ENERGY STAR)
the unit's filed height, width, depth or tank diameter, in inches
Input voltage and maximum current (ENERGY STAR)
the circuit voltage the unit is certified on and the most current it draws

What ENERGY STAR lists for this model

Ambient temperature
37°F min
Physical footprint
24.3" ⌀
Electrical supply
240V, 21A max
ENERGY STAR · 2026-10-25

What these figures mean

The registry lists a UEF, the ratio of hot water delivered to energy used, of 4.05 for the Rheem PROPH65 T2 RH375-SO. This site combines that value with the DOE test's daily hot-water draw for the high draw pattern and arrives at 1,225 kWh of electricity a year. The figure is a calculation, not a metered result, and it rests on DOE CCD data retrieved 2026-10-25. Among the 204 models registered as an electric tank at the high draw pattern, this unit has the 22nd lowest energy use. That places it in the lowest quarter of its class, where the median is 1,306 kWh.

The gap from the class median is 81 kWh a year, and it holds only at the federal test's draw. This unit has a first hour rating, the gallons of hot water available in the first hour from a full tank, of 75 gallons and a rated volume of 59 gallons. It is listed under the high draw pattern, which means a larger household, or one where showers and laundry overlap. A household whose daily use differs from the test draw may not see the 1,225 kWh figure, and this page cannot say by how much, because measured household use is not available. The water heater selector by fuel, space and size helps when the draw pattern does not fit.

Read the rest

Running cost is not stated here because it depends on your own utility electricity tariff. Multiplying 1,225 kWh by your rate gives the yearly electricity cost at the test draw. The cost calculator on your own ZIP does this for you, and the methodology for the annual cost explains each step. The modeled installed-cost range appears in its own block with its source and date, and it is a range, not a quote. To compare this model against others in the same class of 204 registered models, find a same-class replacement by model number.

DOE CCD · 2026-10-25

How this compares

The closest models in the same class — same fuel, type and draw pattern — that have their own comparison page.


Keep going

1,225 kWh/yr Grade B Cost on your ZIP

Page last updated