DoesTheMath

Rheem PROPH65 T0 RH120-M

3.12 UEF DOE CCD · 2026-09-19
C

Grade C: where this UEF sits among the 426 models in its class, lowest (G) to highest (A). A position, not an official label. How the grade is set

An electric tank, medium draw pattern (a typical three- or four-person household, about 55 gallons on a busy morning).

If you are checking the Rheem PROPH65 T0 RH120-M, this electric tank uses 1,041 kWh of electricity a year. That figure applies at the medium draw pattern, the standard daily hot-water usage DOE tests against. It sits 2,490 kWh below the class median of 3,531 kWh, ranking 112th lowest in energy use of 426 comparable models.


Energy use per year

1,041 kWh a year

Computed by this site from the registry's UEF and the federal test's daily hot-water draw for this draw pattern. What it costs depends on the electricity rate where you live.

That is below the median of 3,531 kWh for the 426 models registered in the same heater type and draw pattern; it ranks 112 of 426, lowest energy first.

This model: 1,041 kWh

Solid line: this model (1,041 kWh). Dashed line: the class median.

Min 773 kWh Median 3,531 kWh Max 3,569 kWh

DOE CCD · 2026-09-19

Report an issue with this number


What it costs to run where you live

Enter your ZIP to see what this unit costs to run a year on your own utility’s electricity rate.


What the registry files

UEF (Uniform Energy Factor) how much hot water you get for each unit of energy the heater uses
3.12 DOE CCD · 2026-09-19 Compared only with other models registered as an electric tank at the medium draw pattern.
Draw Pattern the standard daily usage profile DOE tests the unit against
Medium DOE CCD · 2026-09-19
First Hour Rating how many gallons of hot water the unit can deliver in one hour, starting from a full tank
63 gal DOE CCD · 2026-09-19
Rated Storage Volume the tank size in gallons
59 gal DOE CCD · 2026-09-19
On the market since (ENERGY STAR) the date the manufacturer told ENERGY STAR the model went on sale
2022-04-21 ENERGY STAR · 2026-09-19
Connected / demand response (ENERGY STAR) whether the unit can take signals from your utility to shift when it heats, and by which standard (such as CTA-2045)
No ENERGY STAR · 2026-09-19
Refrigerant and GWP (ENERGY STAR) the refrigerant a heat pump unit uses and its global warming potential, a leak's climate effect relative to carbon dioxide (CO2 = 1)
R-134a, GWP 1430 ENERGY STAR · 2026-09-19

What it costs to install

$3,406–$3,902 installed

Not a quote — a modeled range of what installers have charged for this class of unit; your price will vary with labor rates, access, and local code requirements.

Escalation indexes: equipment (BLS PPI) latest available: August 2026; labor (BLS ECI) latest available: April 2026 to June 2026.

NLR REMDB (BLS PPI/ECI escalated) · 2026-04-01

Report an issue with this number


Safety record

No CPSC recall names this model.

Checked against the CPSC recall database. CPSC does not publish a model-level match for this product category, so this list is curated by hand from the manufacturer's recall filings.

CPSC · 2026-09-24

Does it fit your space?

Enter your own numbers below — this compares them to what ENERGY STAR publishes for this model, it does not tell you what to buy.

Compressor operating range (ENERGY STAR)
the air temperatures around the unit in which its heat pump runs; outside this range the heat pump stops
Dimensions (ENERGY STAR)
the unit's filed height, width, depth or tank diameter, in inches
Input voltage and maximum current (ENERGY STAR)
the circuit voltage the unit is certified on and the most current it draws
  • Ambient temperatureEnter your numbers37°F min
  • Physical footprintEnter your numbers24.3" ⌀
  • Electrical supplyEnter your numbers120V, 12A max
ENERGY STAR · 2026-09-19

What these figures mean

This site calculated the 1,041 kWh figure; the registry does not publish it. It combines the model's registered UEF, the ratio of hot water delivered to energy used, with the DOE test's daily hot-water draw for the medium pattern. For the Rheem PROPH65 T0 RH120-M, the UEF is 3.12. The medium pattern represents a typical household's hot-water use, including a busy morning. The figure therefore holds only at that federal test draw. A home that draws more or less hot water each day will not use exactly 1,041 kWh. The registry gives no figure for other usage levels, so none is shown here. The same energy figure feeds the running cost, as set out in how the annual cost is calculated.

The class is the 426 models registered as an electric tank at the medium draw pattern. A rank of 112th places this model below the class median, but not at the lowest position. Fit depends on demand as well as energy. The first hour rating, the gallons of hot water available in the first hour from a full tank, is 63 gallons. The rated volume is 59 gallons. A household whose busiest hour stays within 63 gallons is inside what the test measured. A household that routinely draws more in one hour is outside that rating. This page has no data on how the unit performs there. To compare other tanks, use the water heater selector by fuel, space and size.

The text does not state a running cost. The cost of 1,041 kWh a year depends on your own utility's electricity tariff, which this page does not know in advance. The page computes it from your ZIP rather than estimating it here. The cost calculator on your own ZIP applies your rate to this model's energy figure at the medium draw pattern. The installed price range appears in its own block with its source and date. That block is a modeled range, not a quote. If you are matching a unit, you can find a same-class replacement by model number using PROPH65 T0 RH120-M. The energy data comes from the DOE CCD, retrieved 2026-09-19.

DOE CCD · 2026-09-19

How this compares

The closest models in the same class — same fuel, type and draw pattern.


Keep going