An electric tank, medium draw pattern (a typical three- or four-person household, about 55 gallons on a busy morning).

If you are verifying the Rheem PROPH40 T0 RH120, it uses 1,254 kWh a year at the medium draw pattern, the standard daily hot-water usage DOE tests against. That is 2,277 kWh below the 3,531 kWh median for electric tanks at this draw pattern, ranking 129th lowest of 426.


Energy use per year

1,254 kWh a year

Computed by this site from the registry's UEF and the federal test's daily hot-water draw for this draw pattern. What it costs depends on the electricity rate where you live.

That is below the median of 3,531 kWh for the 426 models registered in the same heater type and draw pattern; it ranks 129 of 426, lowest energy first.

This model: 1,254 kWh

Solid line: this model (1,254 kWh). Dashed line: the class median.

Min 773 kWh Median 3,531 kWh Max 3,569 kWh

DOE CCD · 2026-09-19

Report an issue with this number


What it costs to run where you live

Enter your ZIP to see what this unit costs to run a year on your own utility’s electricity rate.


What the registry files

UEF (Uniform Energy Factor) how much hot water you get for each unit of energy the heater uses
2.59 DOE CCD · 2026-09-19 Compared only with other models registered as an electric tank at the medium draw pattern.
Draw Pattern the standard daily usage profile DOE tests the unit against
Medium DOE CCD · 2026-09-19
First Hour Rating how many gallons of hot water the unit can deliver in one hour, starting from a full tank
43 gal DOE CCD · 2026-09-19
Rated Storage Volume the tank size in gallons
37 gal DOE CCD · 2026-09-19

What it costs to install

Not published: Installed cost range

This model's UEF lies outside the range NLR REMDB's cost model was fitted on, and the range is not stretched past it.

The annual energy figure on this page does not depend on this range and is unaffected.


Safety record

No CPSC recall names this model.

Checked against the CPSC recall database. CPSC does not publish a model-level match for this product category, so this list is curated by hand from the manufacturer's recall filings.

CPSC · 2026-09-24

What these figures mean

The 1,254 kWh figure is calculated by this site, not published in the registry. It combines the registry's UEF, the ratio of hot water delivered to energy used, with the DOE test's daily hot-water draw. This model's UEF of 2.59 comes from the DOE Compliance Certification Database, retrieved 2026-09-19. The figure applies only at the medium draw pattern, which describes a typical household's hot-water use on a busy morning. The 426 models in its class are all compared at this same medium draw pattern. A home that draws more or less hot water than the test assumes will use a different amount than 1,254 kWh a year.

The tank's rated volume is 37 gallons. Its first hour rating, the gallons of hot water available in the first hour from a full tank, is 43 gallons. The figures fit a household whose busiest hour of hot-water use stays within 43 gallons. A household that regularly needs more than 43 gallons in its busiest hour is outside what this rating covers. Its 129th place puts it in the second-lowest quarter of its class; models in the lowest quarter use less energy. To compare it with other medium-draw electric tanks, find a same-class replacement by model number, or filter models by fuel, space and size.

This page does not state a running cost, because the cost of 1,254 kWh a year depends on your own utility's electricity tariff. Instead, the page computes it from your ZIP code; the cost calculator for your own ZIP shows the result. How the annual cost is calculated describes the steps between the energy figure and that cost. An installed price range is not published for this model. Its ratings, including the UEF of 2.59, lie outside the range the cost database's model was fitted on. The site does not stretch that range to cover it. Energy use at other draw patterns is not available on this page.