RELIANCE WATER HEATERS T-H3J-DV-N 1**
0.94 UEF DOE CCD · 2026-09-19Grade B: where this UEF sits among the 397 models in its class, lowest (G) to highest (A). A position, not an official label. How the grade is set
A gas tankless unit, high draw pattern (a larger household, or one where showers and laundry overlap).
If you are checking this unit's registry figures: at the high draw pattern, the standard daily hot-water usage DOE tests against, the RELIANCE WATER HEATERS T-H3J-DV-N 1** uses 180 therms of natural gas a year. That is 2 therms below the 182 therms median of the 397 gas tankless units registered at this draw pattern.
Energy use per year
180 therms a year
Computed by this site from the registry's UEF and the federal test's daily hot-water draw for this draw pattern. What it costs depends on the natural gas rate where you live.
That is below the median of 182 therms for the 397 models registered in the same heater type and draw pattern; it ranks 165 of 397, lowest energy first.
Solid line: this model (180 therms). Dashed line: the class median.
Min 173 therms Median 182 therms Max 209 therms
What it costs to run where you live
What the registry files
- UEF (Uniform Energy Factor) how much hot water you get for each unit of energy the heater uses
- 0.94 DOE CCD · 2026-09-19 Compared only with other models registered as a gas tankless unit at the high draw pattern.
- Draw Pattern the standard daily usage profile DOE tests the unit against
- High DOE CCD · 2026-09-19
- Maximum Gallons Per Minute how many gallons a minute it can heat while running continuously
- 4.7 gal/min DOE CCD · 2026-09-19
What it costs to install
$2,311–$3,350 installed
Not a quote — a modeled range of what installers have charged for this class of unit; your price will vary with labor rates, access, and local code requirements.
Escalation indexes: equipment (BLS PPI) latest available: August 2026; labor (BLS ECI) latest available: April 2026 to June 2026.
NLR REMDB (BLS PPI/ECI escalated) · 2026-04-01Safety record
No CPSC recall names this model.
Checked against the CPSC recall database. CPSC does not publish a model-level match for this product category, so this list is curated by hand from the manufacturer's recall filings.
CPSC · 2026-09-24What these figures mean
How this compares
The closest models in the same class — same fuel, type and draw pattern.
Keep going
How every figure on this page is calculated
-
Find what replaces your water heater
Enter the model number off your old unit and see what is on file today, with the yearly cost difference.
-
Find a water heater that fits
Three questions — fuel, hot water need, install space — narrow every model on file to the ones that fit.
-
What a water heater costs to run
Prices a unit's efficiency against your own utility's filed tariff for your ZIP code.
-
How to size a tankless water heater by GPM
Answered from what models in this size actually file.
-
Water heaters
Every model on file with the Department of Energy, by heater type.
-
All gas tankless water heaters
Gas-fired instantaneous units, sized by flow rate rather than tank gallons.
-
Every RELIANCE WATER HEATERS model on file
What this brand files, by heater type.
UEF 0.94 · Grade B Price it on your ZIP
The 180 therms figure is computed by this site, not taken from the registry. It combines the registry's UEF, the ratio of hot water delivered to energy used, with the DOE test's daily hot-water draw. This model's UEF is 0.94, from DOE CCD data retrieved 2026-09-19. The figure holds only at that test draw. A household drawing more or less hot water will use a different amount of gas. Among the 397 models in its class, it ranks 165th lowest in energy use. That places it in the second-lowest quarter of its class for energy use. The method behind the annual figures explains each step of the calculation.
The high draw pattern describes a larger household, or one where showers and laundry overlap. The registry lists a maximum flow rate in gallons per minute of 4.7 for this unit. That is the limit on hot water delivered at one time. Whether it covers a given set of fixtures depends on their flow rates, which are not in this data. A home using less hot water than the high draw pattern falls outside the condition behind the 180 therms figure. For such a home, energy use at a lower draw is not available on this page. The selector by fuel, space and size filters other registered units. The same-class replacement search by model number lists units in this class.
The running cost is not stated in this text. It depends on your state's average residential natural gas price, so the page computes it from your ZIP. Multiplying 180 therms by that rate gives the yearly cost at the high draw pattern. At any one rate, this model's cost differs from a median unit's by the price of 2 therms of gas. The installed price range appears in its own block, with its source and date. It is a modeled range, not a quote. Actual gas use away from the federal test draw is not known from the registry. The cost calculator for your own ZIP applies your rate to this model's figure.
DOE CCD · 2026-09-19