DoesTheMath

RELIANCE WATER HEATERS HPTU-50N 1**

3.45 UEF DOE CCD · 2026-09-19
B

Grade B: where this UEF sits among the 426 models in its class, lowest (G) to highest (A). A position, not an official label. How the grade is set

An electric tank, medium draw pattern (a typical three- or four-person household, about 55 gallons on a busy morning).

If you are checking the RELIANCE WATER HEATERS HPTU-50N 1**, an electric tank water heater, it uses 942 kWh of electricity a year at the medium draw pattern, the standard daily hot-water usage DOE tests against. That is 2,589 kWh below its class median of 3,531 kWh, and it ranks 93rd lowest of 426 models.


Energy use per year

942 kWh a year

Computed by this site from the registry's UEF and the federal test's daily hot-water draw for this draw pattern. What it costs depends on the electricity rate where you live.

That is below the median of 3,531 kWh for the 426 models registered in the same heater type and draw pattern; it ranks 93 of 426, lowest energy first.

This model: 942 kWh

Solid line: this model (942 kWh). Dashed line: the class median.

Min 773 kWh Median 3,531 kWh Max 3,569 kWh

DOE CCD · 2026-09-19

Report an issue with this number


What it costs to run where you live

Enter your ZIP to see what this unit costs to run a year on your own utility’s electricity rate.


What the registry files

UEF (Uniform Energy Factor) how much hot water you get for each unit of energy the heater uses
3.45 DOE CCD · 2026-09-19 Compared only with other models registered as an electric tank at the medium draw pattern.
Draw Pattern the standard daily usage profile DOE tests the unit against
Medium DOE CCD · 2026-09-19
First Hour Rating how many gallons of hot water the unit can deliver in one hour, starting from a full tank
66 gal DOE CCD · 2026-09-19
Rated Storage Volume the tank size in gallons
46 gal DOE CCD · 2026-09-19
On the market since (ENERGY STAR) the date the manufacturer told ENERGY STAR the model went on sale
2019-04-05 ENERGY STAR · 2026-09-19
Connected / demand response (ENERGY STAR) whether the unit can take signals from your utility to shift when it heats, and by which standard (such as CTA-2045)
No ENERGY STAR · 2026-09-19
Refrigerant and GWP (ENERGY STAR) the refrigerant a heat pump unit uses and its global warming potential, a leak's climate effect relative to carbon dioxide (CO2 = 1)
R-134a, GWP 1430 ENERGY STAR · 2026-09-19

What it costs to install

$3,022–$4,110 installed

Not a quote — a modeled range of what installers have charged for this class of unit; your price will vary with labor rates, access, and local code requirements.

Escalation indexes: equipment (BLS PPI) latest available: August 2026; labor (BLS ECI) latest available: April 2026 to June 2026.

NLR REMDB (BLS PPI/ECI escalated) · 2026-04-01

Report an issue with this number


Safety record

No CPSC recall names this model.

Checked against the CPSC recall database. CPSC does not publish a model-level match for this product category, so this list is curated by hand from the manufacturer's recall filings.

CPSC · 2026-09-24

Does it fit your space?

Enter your own numbers below — this compares them to what ENERGY STAR publishes for this model, it does not tell you what to buy.

Compressor operating range (ENERGY STAR)
the air temperatures around the unit in which its heat pump runs; outside this range the heat pump stops
Dimensions (ENERGY STAR)
the unit's filed height, width, depth or tank diameter, in inches
Input voltage and maximum current (ENERGY STAR)
the circuit voltage the unit is certified on and the most current it draws
  • Ambient temperatureEnter your numbers45°F min
  • Physical footprintEnter your numbers15" ⌀
  • Electrical supplyEnter your numbers240V, 22A max
ENERGY STAR · 2026-09-19

What these figures mean

The registry does not print the 942 kWh figure. This site calculated it from two inputs: the registry's UEF, the ratio of hot water delivered to energy used, and the daily hot-water draw that the DOE test sets for the medium pattern. This model's listed UEF is 3.45, from the DOE CCD retrieved 2026-09-19. The medium pattern represents a typical household's daily use, so the figure applies only at that draw. With a higher or lower daily draw, the yearly figure would be different. This data does not include energy use at other draw patterns. The site explains each step in how the annual energy and cost figures are calculated.

All 426 models in this comparison are registered as an electric tank at the medium draw pattern. Their median energy use is 3,531 kWh a year. This model is 2,589 kWh below that median, which puts it in the lowest quarter of its class for energy use. Its rated volume is 46 gallons. Its first hour rating, the gallons of hot water available in the first hour from a full tank, is 66 gallons. If you are checking a job, look at both figures. The energy rank holds at the medium pattern, and the first hour rating shows supply at peak. The rank's conditions fit a home whose busiest hour needs no more than 66 gallons. To compare other fuels and sizes, use the water heater selector by fuel, space and size.

The model is not rated to supply a home whose busiest hour needs more than 66 gallons. For that home, the 93rd rank among 426 models does not describe the whole picture. The 942 kWh figure also does not carry over to a home with a different daily draw. This page does not state a running cost, because the cost depends on your own electricity tariff. You can work it out with the cost calculator for your own ZIP. The installed price range has its own block, with its source and date. That range is a modeled estimate, not a quote. To check a same-class alternative, find a replacement by model number.

DOE CCD · 2026-09-19

How this compares

The closest models in the same class — same fuel, type and draw pattern.


Keep going

UEF 3.45 · Grade B Price it on your ZIP