RELIANCE WATER HEATERS GUR 40 4**
0.64 UEF DOE CCD · 2026-09-19Grade G: where this UEF sits among the 414 models in its class, lowest (G) to highest (A). A position, not an official label. How the grade is set
A gas tank, high draw pattern (a larger household, or one where showers and laundry overlap).
Verifying the RELIANCE WATER HEATERS GUR 40 4**? This gas tank water heater uses 264 therms of natural gas a year. That figure belongs to the high draw pattern, the standard daily hot-water usage DOE tests against. It sits 4 therms above its class median of 260 therms, ranking 236th lowest of 414.
Energy use per year
264 therms a year
Computed by this site from the registry's UEF and the federal test's daily hot-water draw for this draw pattern. What it costs depends on the natural gas rate where you live.
That is above the median of 260 therms for the 414 models registered in the same heater type and draw pattern; it ranks 236 of 414, lowest energy first.
Solid line: this model (264 therms). Dashed line: the class median.
Min 188 therms Median 260 therms Max 277 therms
What it costs to run where you live
What the registry files
- UEF (Uniform Energy Factor) how much hot water you get for each unit of energy the heater uses
- 0.64 DOE CCD · 2026-09-19 Compared only with other models registered as a gas tank at the high draw pattern.
- Draw Pattern the standard daily usage profile DOE tests the unit against
- High DOE CCD · 2026-09-19
- First Hour Rating how many gallons of hot water the unit can deliver in one hour, starting from a full tank
- 83 gal DOE CCD · 2026-09-19
- Rated Storage Volume the tank size in gallons
- 38 gal DOE CCD · 2026-09-19
What it costs to install
$1,643–$2,763 installed
Not a quote — a modeled range of what installers have charged for this class of unit; your price will vary with labor rates, access, and local code requirements.
Escalation indexes: equipment (BLS PPI) latest available: August 2026; labor (BLS ECI) latest available: April 2026 to June 2026.
NLR REMDB (BLS PPI/ECI escalated) · 2026-04-01Safety record
No CPSC recall names this model.
Checked against the CPSC recall database. CPSC does not publish a model-level match for this product category, so this list is curated by hand from the manufacturer's recall filings.
CPSC · 2026-09-24What these figures mean
How this compares
The closest models in the same class — same fuel, type and draw pattern.
Keep going
How every figure on this page is calculated
-
Find what replaces your water heater
Enter the model number off your old unit and see what is on file today, with the yearly cost difference.
-
Find a water heater that fits
Three questions — fuel, hot water need, install space — narrow every model on file to the ones that fit.
-
What a water heater costs to run
Prices a unit's efficiency against your own utility's filed tariff for your ZIP code.
-
Is a 40-gallon water heater enough?
Answered from what models in this size actually file.
-
Water heaters
Every model on file with the Department of Energy, by heater type.
-
All gas tank water heaters
Gas-fired storage tanks, every size and draw pattern on file.
-
Every RELIANCE WATER HEATERS model on file
What this brand files, by heater type.
UEF 0.64 · Grade G Price it on your ZIP
This site computes the 264 therms figure; the registry does not publish it. It combines the registry's UEF, the ratio of hot water delivered to energy used, with the daily hot-water draw the DOE test sets for the high draw pattern. For this model the UEF is 0.64. The figure therefore holds only at that test draw. A home that draws more hot water each day would use more gas than 264 therms, and a home that draws less would use less. The registry data behind it comes from the DOE CCD, retrieved 2026-09-19. The full calculation steps are set out in how the annual energy and cost figures are calculated.
The high draw pattern describes a larger household, or one where showers and laundry overlap. This unit's first hour rating, the gallons of hot water available in the first hour from a full tank, is 83 gallons, from a rated volume of 38 gallons. Those two figures and the draw pattern show the kind of demand the unit was tested against. A household with lighter daily use is not the case the 264 therms figure describes. Its annual gas use at a lighter draw is not available here. Whether the unit fits a given home depends on that home's peak hot-water use, which the registry does not record. To compare other units, use the water heater selector by fuel, space and size.
The class here is the 414 models registered as a gas tank at the high draw pattern. The 4 therms gap above the median, noted at the top of the page, places this unit in the second-highest quarter of its class for energy use. The running cost is not stated in this text. It depends on the reader's state average residential gas price, so the page computes it from the reader's ZIP, using 264 therms as the input. You can run the same figure in the cost calculator for your own ZIP. The modeled installed-cost range appears in its own block, with its source and date, and it is not a quote. To look up units in the same class, use the same-class replacement finder by model number.
DOE CCD · 2026-09-19