3,493 kWh a year DOE CCD (opens in a new tab) (the U.S. Department of Energy’s Compliance Certification Database) · 2026-10-25

UEF 0.93 filed efficiency; the yearly figure is computed from it

G
  1. G at least 0.91 , this model's grade
  2. F at least 1.38
  3. E at least 1.85
  4. D at least 2.32
  5. C at least 2.79
  6. B at least 3.26
  7. A at least 3.73

Grade G: where this UEF sits among the 452 models in its class, lowest (G) to highest (A). A position, not an official label. How the grade is set

An electric tank, medium draw pattern (a typical three- or four-person household, about 55 gallons on a busy morning).

Label numbers this filing covers (1)

The model number on your rating plate may be any of these; each is filed under this one listing.

  • RC40G-E

Checking the Ranein RC40G? It uses 3,493 kWh of electricity a year at the medium draw pattern, the standard daily hot-water usage DOE tests against. That equals the class median of 3,493 kWh among 452 electric tank models, a difference of 0 kWh. This site computes the figure from registry data.


Energy use per year

3,493 kWh a year

Computed by this site from the registry's UEF and the federal test's daily hot-water draw for this draw pattern. What it costs depends on the electricity rate where you live.

This model is in the second-lowest quarter of its class for energy use. That is equal to the median of 3,493 kWh for the 452 models registered in the same heater type and draw pattern; it ranks 174 of 452, lowest energy first.

This model 3,493 kWh

This model: 3,493 kWh

Median 3,493 kWh

Min 773 kWh Max 3,569 kWh

DOE CCD (opens in a new tab) · 2026-10-25

Report an issue with this number


What it costs to run where you live

Enter your ZIP to see what this unit costs to run a year on your own utility’s electricity rate.


What the registry files

From DOE CCD · 2026-10-25

UEF (Uniform Energy Factor) how much hot water you get for each unit of energy the heater uses
0.93 Compared only with other models registered as an electric tank at the medium draw pattern.
Draw Pattern the standard daily usage profile DOE tests the unit against
Medium
First Hour Rating how many gallons of hot water the unit can deliver in one hour, starting from a full tank
57 gal
Rated Storage Volume the tank size in gallons
40 gal Rated volume is the size the registry files. The number in a model name is the maker's nominal size and can differ: a "40-gallon" model may be rated at 36.

Installed cost and service life

$1,661–$2,129 installed

Not a quote — a modeled range of what installers have charged for this class of unit; your price will vary with labor rates, access, and local code requirements.

Brought to current prices with Bureau of Labor Statistics indexes: equipment to May 2026, installation labor to April 2026–June 2026.

NLR REMDB (BLS PPI/ECI escalated) · 2026-04-01

Report an issue with this number

Service life: DOE’s cost database assumes 14.8 years for electric resistance tanks. That is a class assumption, not this model’s rating or a warranty — no registry publishes either.

NLR REMDB v4.0.0 · 2026-09-07

Safety record

No CPSC recall names this model.

Checked against the CPSC recall database. CPSC does not publish a model-level match for this product category, so this list is curated by hand from the manufacturer's recall filings.

CPSC · 2026-09-24

What these figures mean

The figure of 3,493 kWh is not a registry entry. This site computed it from the registry's UEF, the ratio of hot water delivered to energy used, and the daily hot-water draw the DOE test sets for this draw pattern. This model's UEF is 0.93. The fuel is electricity, and the source is DOE CCD, retrieved 2026-10-25. Because the figure is 3,493 kWh and the class median is 3,493 kWh, the difference is 0 kWh. The unit ranks 174th lowest energy use of 452, which puts it in the second-lowest quarter of its class for energy use. All of this holds only for the medium draw pattern.

The medium draw pattern is the one the figure was computed for. It suits a reader whose household hot-water use resembles that pattern, and for that reader 3,493 kWh is the number to compare with the class median of 3,493 kWh. It suits less well a reader whose use differs, because this data gives no figure for any other pattern. The first hour rating, the gallons of hot water available in the first hour from a full tank, is 57 gallons on a rated volume of 40 gallons. These are registry values and do not show how a given home will use them. To narrow options by fuel, space and size, use the water heater selector, or find a same-class replacement by model number.

Read the rest

Running cost is not stated in this text, because it depends on your own utility electricity tariff. The annual energy of 3,493 kWh is the quantity that tariff is applied to. The cost calculator on your own ZIP does that step, and the page on how the annual cost is calculated explains the method. The installed price range appears in its own block with its source and date, as a modeled range and not a quote, so it is not restated here. Not available from this data: metered use in a particular home, and any figure for a draw pattern other than medium. With a difference of 0 kWh from the class median, annual energy alone does not separate this model from the median unit of its class.

DOE CCD · 2026-10-25

How this compares

The closest models in the same class — same fuel, type and draw pattern — that have their own comparison page.


Keep going

3,493 kWh/yr Grade G Cost on your ZIP

Page last updated