An electric tank, medium draw pattern (a typical three- or four-person household, about 55 gallons on a busy morning).

If you are checking the PolarWave ACIQ-50G-HP-WH, an electric tank unit, it uses 866 kWh of electricity a year at the medium draw pattern. That pattern is the standard daily hot-water usage DOE tests against. The model is 2,665 kWh below the class median of 3,531 kWh and ranks 21st lowest in energy use of 426 comparable models.


Energy use per year

866 kWh a year

Computed by this site from the registry's UEF and the federal test's daily hot-water draw for this draw pattern. What it costs depends on the electricity rate where you live.

That is below the median of 3,531 kWh for the 426 models registered in the same heater type and draw pattern; it ranks 21 of 426, lowest energy first.

This model: 866 kWh

Solid line: this model (866 kWh). Dashed line: the class median.

Min 773 kWh Median 3,531 kWh Max 3,569 kWh

DOE CCD · 2026-09-19

Report an issue with this number


What it costs to run where you live

Enter your ZIP to see what this unit costs to run a year on your own utility’s electricity rate.


What the registry files

UEF (Uniform Energy Factor) how much hot water you get for each unit of energy the heater uses
3.75 DOE CCD · 2026-09-19 Compared only with other models registered as an electric tank at the medium draw pattern.
Draw Pattern the standard daily usage profile DOE tests the unit against
Medium DOE CCD · 2026-09-19
First Hour Rating how many gallons of hot water the unit can deliver in one hour, starting from a full tank
69 gal DOE CCD · 2026-09-19
Rated Storage Volume the tank size in gallons
47 gal DOE CCD · 2026-09-19
On the market since (ENERGY STAR) the date the manufacturer told ENERGY STAR the model went on sale
2024-05-30 ENERGY STAR · 2026-09-19
Connected / demand response (ENERGY STAR) whether the unit can take signals from your utility to shift when it heats, and by which standard (such as CTA-2045)
Yes (CTA-2045-B) ENERGY STAR · 2026-09-19
Refrigerant and GWP (ENERGY STAR) the refrigerant a heat pump unit uses and its global warming potential, a leak's climate effect relative to carbon dioxide (CO2 = 1)
R-134a, GWP 1430 ENERGY STAR · 2026-09-19
Sound level (ENERGY STAR) how loud the unit is while it runs, in decibels as filed
49 dB ENERGY STAR · 2026-09-19

What it costs to install

$3,089–$4,419 installed

Not a quote — a modeled range of what installers have charged for this class of unit; your price will vary with labor rates, access, and local code requirements.

Escalation indexes: equipment (BLS PPI) latest available: August 2026; labor (BLS ECI) latest available: April 2026 to June 2026.

NLR REMDB (BLS PPI/ECI escalated) · 2026-04-01

Report an issue with this number


Safety record

No CPSC recall names this model.

Checked against the CPSC recall database. CPSC does not publish a model-level match for this product category, so this list is curated by hand from the manufacturer's recall filings.

CPSC · 2026-09-24

Does it fit your space?

Enter your own numbers below — this compares them to what ENERGY STAR publishes for this model, it does not tell you what to buy.

Compressor operating range (ENERGY STAR)
the air temperatures around the unit in which its heat pump runs; outside this range the heat pump stops
Dimensions (ENERGY STAR)
the unit's filed height, width, depth or tank diameter, in inches
Input voltage and maximum current (ENERGY STAR)
the circuit voltage the unit is certified on and the most current it draws
  • Ambient temperatureEnter your numbers37.4°F min, 107.6°F max
  • Physical footprintEnter your numbers18.3" ⌀
  • Electrical supplyEnter your numbers240V, 24A max
ENERGY STAR · 2026-09-19

What these figures mean

The 866 kWh total is this site's calculation, not a registry value. It starts from this model's UEF, the ratio of hot water delivered to energy used. The registry lists that ratio as 3.75. The calculation then applies the DOE test's daily hot-water draw for the medium pattern. The medium pattern represents a typical household's daily hot-water use, so the total holds only at that test draw. Energy use at your household's own daily draw, or at another draw pattern, is not available here. The UEF comes from DOE's Compliance Certification Database (CCD), retrieved 2026-09-19. Each step behind the total is set out in how this site calculates annual energy and cost.

The 21st ranking in the summary compares this model with the 426 models registered as an electric tank at the medium draw pattern. Its first hour rating, the gallons of hot water available in the first hour from a full tank, is 69 gallons. That rating comes from a rated volume of 47 gallons. The figures fit a household whose busiest hour stays within 69 gallons of hot water. A household that needs more than 69 gallons in its busiest hour falls outside what this rating covers. To compare other units, use the water heater selector by fuel, space and size. To match an existing unit, find a same-class replacement by model number.

The running cost is not written in this text, because it depends on your own utility's electricity tariff. The page computes it from your ZIP, using 866 kWh a year at the medium draw pattern. Enter your ZIP in the water heater running-cost calculator to see that figure. The 2,665 kWh gap against the class median also converts to cost only at your own rate. The installed price range appears in its own block, with its source and date. It is a modeled installed-cost range, not a quote. This data cannot show what the model costs to run at your household's actual hot-water use.

DOE CCD · 2026-09-19

How this compares

The closest models in the same class — same fuel, type and draw pattern.


Keep going

UEF 3.75 · Grade A Price it on your ZIP