Noritz NR98SV (GQ-2857WX-F US)
0.82 UEF DOE CCD · 2026-09-19Grade G: where this UEF sits among the 397 models in its class, lowest (G) to highest (A). A position, not an official label. How the grade is set
A gas tankless unit, high draw pattern (a larger household, or one where showers and laundry overlap).
If you are checking this model against a spec sheet or a quote, the Noritz NR98SV (GQ-2857WX-F US) uses 206 therms of natural gas a year. That figure applies at the high draw pattern, the standard daily hot-water usage DOE tests against. It is 24 therms above the median of 182 therms for the 397 models in its class.
Energy use per year
206 therms a year
Computed by this site from the registry's UEF and the federal test's daily hot-water draw for this draw pattern. What it costs depends on the natural gas rate where you live.
That is above the median of 182 therms for the 397 models registered in the same heater type and draw pattern; it ranks 229 of 397, lowest energy first.
Solid line: this model (206 therms). Dashed line: the class median.
Min 173 therms Median 182 therms Max 209 therms
What it costs to run where you live
What the registry files
- UEF (Uniform Energy Factor) how much hot water you get for each unit of energy the heater uses
- 0.82 DOE CCD · 2026-09-19 Compared only with other models registered as a gas tankless unit at the high draw pattern.
- Draw Pattern the standard daily usage profile DOE tests the unit against
- High DOE CCD · 2026-09-19
- Maximum Gallons Per Minute how many gallons a minute it can heat while running continuously
- 5.1 gal/min DOE CCD · 2026-09-19
What it costs to install
$1,745–$2,687 installed
Not a quote — a modeled range of what installers have charged for this class of unit; your price will vary with labor rates, access, and local code requirements.
Escalation indexes: equipment (BLS PPI) latest available: August 2026; labor (BLS ECI) latest available: April 2026 to June 2026.
NLR REMDB (BLS PPI/ECI escalated) · 2026-04-01Safety record
No CPSC recall names this model.
Checked against the CPSC recall database. CPSC does not publish a model-level match for this product category, so this list is curated by hand from the manufacturer's recall filings.
CPSC · 2026-09-24What these figures mean
How this compares
The closest models in the same class — same fuel, type and draw pattern.
Keep going
How every figure on this page is calculated
-
Find what replaces your water heater
Enter the model number off your old unit and see what is on file today, with the yearly cost difference.
-
Find a water heater that fits
Three questions — fuel, hot water need, install space — narrow every model on file to the ones that fit.
-
What a water heater costs to run
Prices a unit's efficiency against your own utility's filed tariff for your ZIP code.
-
How to size a tankless water heater by GPM
Answered from what models in this size actually file.
-
Water heaters
Every model on file with the Department of Energy, by heater type.
-
All gas tankless water heaters
Gas-fired instantaneous units, sized by flow rate rather than tank gallons.
-
Every Noritz model on file
What this brand files, by heater type.
UEF 0.82 · Grade G Price it on your ZIP
This site calculated the 206 therms figure. The registry does not list it. The calculation uses the registry's UEF, the ratio of hot water delivered to energy used, which is 0.82 for this unit. It combines that with the DOE test's daily hot-water draw for the high draw pattern. The result describes gas use under the federal test's daily draw, not in any particular home. A household that draws more hot water each day than the test assumes will use more than 206 therms. One that draws less will use less. The underlying registry data comes from DOE CCD, retrieved 2026-09-19. You can see each step on the page explaining how the annual cost is calculated.
The high draw pattern represents a larger household, or one where showers and laundry overlap. This unit's maximum flow rate in gallons per minute is 5.1, according to the registry. Among the 397 gas tankless models registered at the high draw pattern, it ranks 229th for lowest energy use. At 24 therms above the class median of 182 therms, it uses more gas under the same test than the median model in its class. Some readers need a unit whose annual gas use at this draw pattern is at or below the median. For them, this model does not meet that mark. You can list lower-use models of the same class with a same-class replacement search by model number.
The text on this page gives no running cost. The yearly cost of 206 therms depends on your state's average residential gas price, so the page calculates it from your ZIP. The same applies to the 24 therms gap between this unit and its class median, because what that gap costs a year depends on your gas rate. This site does not know your rate until you enter a ZIP, so no cost figure is stated here. The installed-price range on this page appears in its own block with its source and date. It is a modeled range, not a quote. You can work out the running cost with the cost calculator for your own ZIP.
DOE CCD · 2026-09-19