Midea JSQ52-26VHUS-NG

0.82 UEF DOE CCD · 2026-09-19
G

Grade G: where this UEF sits among the 397 models in its class, lowest (G) to highest (A). A position, not an official label. How the grade is set

A gas tankless unit, high draw pattern (a larger household, or one where showers and laundry overlap).

If you are checking this unit against the registry, Midea JSQ52-26VHUS-NG uses 206 therms of natural gas a year at the high draw pattern, the standard daily hot-water usage DOE tests against. That is 24 therms above the class median of 182 therms, and it ranks 229th lowest in energy use of 397 models.


Energy use per year

206 therms a year

Computed by this site from the registry's UEF and the federal test's daily hot-water draw for this draw pattern. What it costs depends on the natural gas rate where you live.

That is above the median of 182 therms for the 397 models registered in the same heater type and draw pattern; it ranks 229 of 397, lowest energy first.

This model: 206 therms

Solid line: this model (206 therms). Dashed line: the class median.

Min 173 therms Median 182 therms Max 209 therms

DOE CCD · 2026-09-19

Report an issue with this number


What it costs to run where you live

Enter your ZIP to see what this unit costs to run a year at your state’s average natural gas price.


What the registry files

UEF (Uniform Energy Factor) how much hot water you get for each unit of energy the heater uses
0.82 DOE CCD · 2026-09-19 Compared only with other models registered as a gas tankless unit at the high draw pattern.
Draw Pattern the standard daily usage profile DOE tests the unit against
High DOE CCD · 2026-09-19
Maximum Gallons Per Minute how many gallons a minute it can heat while running continuously
4.9 gal/min DOE CCD · 2026-09-19

What it costs to install

$1,745–$2,687 installed

Not a quote — a modeled range of what installers have charged for this class of unit; your price will vary with labor rates, access, and local code requirements.

Escalation indexes: equipment (BLS PPI) latest available: August 2026; labor (BLS ECI) latest available: April 2026 to June 2026.

NLR REMDB (BLS PPI/ECI escalated) · 2026-04-01

Report an issue with this number


Safety record

No CPSC recall names this model.

Checked against the CPSC recall database. CPSC does not publish a model-level match for this product category, so this list is curated by hand from the manufacturer's recall filings.

CPSC · 2026-09-24

What these figures mean

This site, not the registry, computes the annual energy figure. It takes the registry's UEF, the ratio of hot water delivered to energy used, of 0.82 and applies the DOE test's daily hot-water draw for the high draw pattern. The result is 206 therms of natural gas a year, from DOE CCD data retrieved 2026-09-19. The comparison group is the 397 models registered as a gas tankless unit at the high draw pattern. Within that group, Midea JSQ52-26VHUS-NG sits 24 therms above the class median of 182 therms. Its rank of 229th lowest puts it in the second-highest quarter of its class for energy use.

The high draw pattern describes a larger household, or one where showers and laundry overlap, so the figure of 206 therms applies only to that kind of use. Energy use at other draw patterns is not available on this page. The registry lists a maximum flow rate in gallons per minute of 4.9. The data here does not say how many fixtures that flow serves at once. For a household that matches the high draw pattern, this unit uses 24 therms more than the class median of 182 therms. A reader whose priority is the lowest energy use in the class should note that 229th lowest of 397 is past the midpoint of the ranking. Real gas use will differ if a household's hot-water use differs from the test draw.

Running cost is not stated here because it depends on your state's average residential gas price. Multiply 206 therms by that price to get a yearly figure at the high draw pattern. The cost calculator on your own ZIP does this for you, and how the annual cost is calculated lists the inputs. The modeled installed-cost range appears in its own block with its source and date. It is not a quote, so this text does not repeat it. The energy figure reflects data retrieved 2026-09-19. To compare JSQ52-26VHUS-NG with other units of its class, you can find a same-class replacement by model number.

DOE CCD · 2026-09-19

How this compares

The closest models in the same class — same fuel, type and draw pattern.


Keep going

UEF 0.82 · Grade G Price it on your ZIP