DoesTheMath

MARATHON MSR50245 C

0.9 UEF DOE CCD · 2026-09-19
G

Grade G: where this UEF sits among the 163 models in its class, lowest (G) to highest (A). A position, not an official label. How the grade is set

An electric tank, low draw pattern (a one- or two-person household).

If you are checking the MARATHON MSR50245 C, it uses 2,494 kWh of electricity a year at the low draw pattern, the standard daily hot-water usage DOE tests against. That is 55 kWh above the class median of 2,439 kWh among 163 electric tank models.


Energy use per year

2,494 kWh a year

Computed by this site from the registry's UEF and the federal test's daily hot-water draw for this draw pattern. What it costs depends on the electricity rate where you live.

That is above the median of 2,439 kWh for the 163 models registered in the same heater type and draw pattern; it ranks 122 of 163, lowest energy first.

This model: 2,494 kWh

Solid line: this model (2,494 kWh). Dashed line: the class median.

Min 724 kWh Median 2,439 kWh Max 2,550 kWh

DOE CCD · 2026-09-19

Report an issue with this number


What it costs to run where you live

Enter your ZIP to see what this unit costs to run a year on your own utility’s electricity rate.


What the registry files

UEF (Uniform Energy Factor) how much hot water you get for each unit of energy the heater uses
0.9 DOE CCD · 2026-09-19 Compared only with other models registered as an electric tank at the low draw pattern.
Draw Pattern the standard daily usage profile DOE tests the unit against
Low DOE CCD · 2026-09-19
First Hour Rating how many gallons of hot water the unit can deliver in one hour, starting from a full tank
41 gal DOE CCD · 2026-09-19
Rated Storage Volume the tank size in gallons
48 gal DOE CCD · 2026-09-19

What it costs to install

Not published: Installed cost range

This model's UEF lies outside the range NLR REMDB's cost model was fitted on, and the range is not stretched past it.

The annual energy figure on this page does not depend on this range and is unaffected.


Safety record

No CPSC recall names this model.

Checked against the CPSC recall database. CPSC does not publish a model-level match for this product category, so this list is curated by hand from the manufacturer's recall filings.

CPSC · 2026-09-24

What these figures mean

This site computes the figure of 2,494 kWh. The registry does not publish it. The calculation combines the registry's UEF, the ratio of hot water delivered to energy used, of 0.9 with the daily hot-water draw the DOE test assigns to the low draw pattern. The data comes from the DOE CCD, retrieved 2026-09-19. Against the class median of 2,439 kWh, this model sits 55 kWh higher. Its rank is 122nd lowest energy use of 163, which places it in the second-highest quarter of its class for energy use. The comparison covers only electric tank models registered at the low draw pattern. The steps behind the calculation are set out on the page about how the annual cost is calculated.

The figure applies only to the low draw pattern. A household whose hot-water use matches that pattern can compare this unit directly with the other models in its class. The unit has a first hour rating, the gallons of hot water available in the first hour from a full tank, of 41 gallons. Its rated volume is 48 gallons. The data does not show energy use under other draw patterns, so that figure is not available here for a household with higher demand. Those readers can use the selector by fuel, space and size to compare other units. Because this model uses 55 kWh more than the class median of 2,439 kWh, it does not suit a reader whose priority is the lowest energy use in the class.

The running cost is not stated in the text because it depends on your own utility electricity tariff. The cost calculator on your own ZIP applies your rate to the 2,494 kWh shown above. The same rate also sets what the 55 kWh gap from the class median costs over a year. The installed price is not published. This model's ratings lie outside the range the cost database's model was fitted on, and that range is not stretched past its limit. If you are verifying a swap for an existing unit, you can find a same-class replacement by model number and compare its figure with the 2,494 kWh on this page.

DOE CCD · 2026-09-19

How this compares

The closest models in the same class — same fuel, type and draw pattern.


Keep going

UEF 0.9 · Grade G Price it on your ZIP