DoesTheMath

LOCHINVAR ENS-40W 1**

0.88 UEF DOE CCD · 2026-09-19
G

Grade G: where this UEF sits among the 163 models in its class, lowest (G) to highest (A). A position, not an official label. How the grade is set

An electric tank, low draw pattern (a one- or two-person household).

You are checking the LOCHINVAR ENS-40W 1**, an electric tank. At the federal test's daily hot-water draw, it uses 2,550 kWh of electricity a year. That figure applies to the low draw pattern, the standard daily hot-water usage DOE tests against. It sits 111 kWh above the median of 2,439 kWh for its class.


Energy use per year

2,550 kWh a year

Computed by this site from the registry's UEF and the federal test's daily hot-water draw for this draw pattern. What it costs depends on the electricity rate where you live.

That is above the median of 2,439 kWh for the 163 models registered in the same heater type and draw pattern; it ranks 158 of 163, lowest energy first.

This model: 2,550 kWh

Solid line: this model (2,550 kWh). Dashed line: the class median.

Min 724 kWh Median 2,439 kWh Max 2,550 kWh

DOE CCD · 2026-09-19

Report an issue with this number


What it costs to run where you live

Enter your ZIP to see what this unit costs to run a year on your own utility’s electricity rate.


What the registry files

UEF (Uniform Energy Factor) how much hot water you get for each unit of energy the heater uses
0.88 DOE CCD · 2026-09-19 Compared only with other models registered as an electric tank at the low draw pattern.
Draw Pattern the standard daily usage profile DOE tests the unit against
Low DOE CCD · 2026-09-19
First Hour Rating how many gallons of hot water the unit can deliver in one hour, starting from a full tank
41 gal DOE CCD · 2026-09-19
Rated Storage Volume the tank size in gallons
37 gal DOE CCD · 2026-09-19

What it costs to install

Not published: Installed cost range

This model's UEF lies outside the range NLR REMDB's cost model was fitted on, and the range is not stretched past it.

The annual energy figure on this page does not depend on this range and is unaffected.


Safety record

No CPSC recall names this model.

Checked against the CPSC recall database. CPSC does not publish a model-level match for this product category, so this list is curated by hand from the manufacturer's recall filings.

CPSC · 2026-09-24

What these figures mean

The 2,550 kWh figure comes from this site's calculation. The registry does not publish it. It combines the registry's UEF, the ratio of hot water delivered to energy used, of 0.88 with the DOE test's daily hot-water draw for the low draw pattern. The source is the DOE CCD, retrieved 2026-09-19. This model is compared with the 163 models registered as an electric tank at the low draw pattern. At that same test draw, their median is 2,439 kWh a year. Ranked from lowest energy use, this model is 158th of 163. The page on how the annual cost is calculated sets out the method behind these figures.

Its first hour rating, the gallons of hot water available in the first hour from a full tank, is 41 gallons. The rated volume is 37 gallons. The 2,550 kWh figure holds only for a household whose daily hot-water use matches the low draw pattern. A household that draws more hot water each day would use more energy than that figure. This page has no figure for heavier use, so that amount is not available here. A household that needs more than 41 gallons in the first hour from a full tank is outside what this rating covers. The selector by fuel, space and size filters models on those limits.

The text on this page gives no running cost. What 2,550 kWh of electricity a year costs depends on your own utility tariff. The cost calculator on your own ZIP works that cost out from your ZIP code. The same tariff sets what the 111 kWh gap above the class median of 2,439 kWh costs you each year. An installed price range is not published for this model. Its ratings lie outside the range the cost database's model was fitted on, and the range is not stretched past it. To compare models in the same class, find a same-class replacement by model number.

DOE CCD · 2026-09-19

How this compares

The closest models in the same class — same fuel, type and draw pattern.


Keep going

UEF 0.88 · Grade G Price it on your ZIP