LOCHINVAR ENL-50 1**

0.92 UEF DOE CCD · 2026-09-19
G

Grade G: where this UEF sits among the 426 models in its class, lowest (G) to highest (A). A position, not an official label. How the grade is set

An electric tank, medium draw pattern (a typical three- or four-person household, about 55 gallons on a busy morning).

If you are checking the LOCHINVAR ENL-50 1**, this electric tank uses 3,531 kWh of electricity a year. That figure applies at the medium draw pattern, the standard daily hot-water usage DOE tests against. It equals the class median of 3,531 kWh, a difference of 0 kWh, and ranks 213th lowest of 426.


Energy use per year

3,531 kWh a year

Computed by this site from the registry's UEF and the federal test's daily hot-water draw for this draw pattern. What it costs depends on the electricity rate where you live.

That is equal to the median of 3,531 kWh for the 426 models registered in the same heater type and draw pattern; it ranks 213 of 426, lowest energy first.

This model: 3,531 kWh

Solid line: this model (3,531 kWh). Dashed line: the class median.

Min 773 kWh Median 3,531 kWh Max 3,569 kWh

DOE CCD · 2026-09-19

Report an issue with this number


What it costs to run where you live

Enter your ZIP to see what this unit costs to run a year on your own utility’s electricity rate.


What the registry files

UEF (Uniform Energy Factor) how much hot water you get for each unit of energy the heater uses
0.92 DOE CCD · 2026-09-19 Compared only with other models registered as an electric tank at the medium draw pattern.
Draw Pattern the standard daily usage profile DOE tests the unit against
Medium DOE CCD · 2026-09-19
First Hour Rating how many gallons of hot water the unit can deliver in one hour, starting from a full tank
51 gal DOE CCD · 2026-09-19
Rated Storage Volume the tank size in gallons
48 gal DOE CCD · 2026-09-19

What it costs to install

$1,765–$2,103 installed

Not a quote — a modeled range of what installers have charged for this class of unit; your price will vary with labor rates, access, and local code requirements.

Escalation indexes: equipment (BLS PPI) latest available: August 2026; labor (BLS ECI) latest available: April 2026 to June 2026.

NLR REMDB (BLS PPI/ECI escalated) · 2026-04-01

Report an issue with this number


Safety record

No CPSC recall names this model.

Checked against the CPSC recall database. CPSC does not publish a model-level match for this product category, so this list is curated by hand from the manufacturer's recall filings.

CPSC · 2026-09-24

What these figures mean

The registry does not print the 3,531 kWh figure. This site calculated it from two inputs. The first is the registry's UEF, the ratio of hot water delivered to energy used. The second is the DOE test's daily hot-water draw for the medium draw pattern. For this model the UEF is 0.92, taken from the DOE CCD and retrieved 2026-09-19. The result holds only at that test draw. A household that uses more hot water each day than the medium pattern assumes will use more electricity than 3,531 kWh. A household that uses less will use less. The page cannot show how much hot water a specific home actually uses. The steps behind the figure are set out in how the annual cost is calculated.

The tank has a rated volume of 48 gallons. It also has a first hour rating, the gallons of hot water available in the first hour from a full tank, of 51 gallons. Those two figures show supply at peak demand; the annual energy figure does not. DOE uses the medium draw pattern to represent a typical mid-sized household on a busy morning. Whether 51 gallons covers a particular home's busiest hour depends on that home's own use. The registry does not record that use, so this page cannot say whether the model suits a given home. If the peak demand calls for a different size, the same-class replacement finder lists models in the same class by model number.

The text does not state a running cost because it depends on your own utility electricity tariff. The cost calculator for your ZIP code applies your rate to 3,531 kWh. The comparison group is the 426 models registered as electric tanks at the medium draw pattern. This model's energy use equals the class median, as shown above. So at any electricity rate, its running cost matches that of a median model in the class. That comparison holds only at the test draw. The installed price range appears in its own block, with its source and date. That range is a modeled installed-cost estimate, not a quote.

DOE CCD · 2026-09-19

How this compares

The closest models in the same class — same fuel, type and draw pattern.


Keep going

UEF 0.92 · Grade G Price it on your ZIP