DoesTheMath

KWICKSHOT TEF055V240

0.96 UEF DOE CCD · 2026-09-19
E

Grade E: where this UEF sits among the 271 models in its class, lowest (G) to highest (A). A position, not an official label. How the grade is set

An electric tankless unit, very small draw pattern (small units - a single bathroom, or a point-of-use heater under a sink).

If you are checking the KWICKSHOT TEF055V240, this electric tankless unit uses 615 kWh of electricity a year. That figure applies to the very small draw pattern, the standard daily hot-water usage DOE tests against. It sits 0 kWh from its class median of 615 kWh, so it is equal to the median.


Energy use per year

615 kWh a year

Computed by this site from the registry's UEF and the federal test's daily hot-water draw for this draw pattern. What it costs depends on the electricity rate where you live.

That is equal to the median of 615 kWh for the 271 models registered in the same heater type and draw pattern; it ranks 77 of 271, lowest energy first.

This model: 615 kWh

Solid line: this model (615 kWh). Dashed line: the class median.

Min 562 kWh Median 615 kWh Max 649 kWh

DOE CCD · 2026-09-19

Report an issue with this number


What it costs to run where you live

Enter your ZIP to see what this unit costs to run a year on your own utility’s electricity rate.


What the registry files

UEF (Uniform Energy Factor) how much hot water you get for each unit of energy the heater uses
0.96 DOE CCD · 2026-09-19 Compared only with other models registered as an electric tankless unit at the very small draw pattern.
Draw Pattern the standard daily usage profile DOE tests the unit against
Very small DOE CCD · 2026-09-19
Maximum Gallons Per Minute how many gallons a minute it can heat while running continuously
0.6 gal/min DOE CCD · 2026-09-19

What it costs to install

$1,306–$1,838 installed

Not a quote — a modeled range of what installers have charged for this class of unit; your price will vary with labor rates, access, and local code requirements.

Escalation indexes: equipment (BLS PPI) latest available: August 2026; labor (BLS ECI) latest available: April 2026 to June 2026.

NLR REMDB (BLS PPI/ECI escalated) · 2026-04-01

Report an issue with this number


Safety record

No CPSC recall names this model.

Checked against the CPSC recall database. CPSC does not publish a model-level match for this product category, so this list is curated by hand from the manufacturer's recall filings.

CPSC · 2026-09-24

What these figures mean

This site computes the 615 kWh figure. The registry does not publish it. The calculation uses the registry's UEF, the ratio of hot water delivered to energy used, together with a fixed daily draw. That draw is the DOE test's daily hot-water draw for the very small draw pattern. This model's UEF is 0.96, from DOE CCD data retrieved 2026-09-19. Its class is the 271 models registered as an electric tankless unit at the very small draw pattern. Within that class, it ranks 77th lowest in energy use of 271. That places it in the second-lowest quarter of its class, and its 0 kWh gap puts it level with the median. The steps behind the figure are set out in how the annual cost is calculated.

The very small draw pattern covers small units, such as a single bathroom or a point-of-use heater under a sink. This model's maximum flow rate in gallons per minute is 0.6, the flow figure the registry lists for it. The 615 kWh figure holds only at the federal test's daily draw for this pattern. A household that uses more hot water each day than the test assumes will use more energy than 615 kWh. The data does not say how much more. A home that needs more than 0.6 at once falls outside what this listing describes. To compare other fuels or sizes, use the selector by fuel, space and size. To stay within this class, find a same-class replacement by model number.

This text does not give a running cost. The cost depends on your own utility's electricity tariff, and this text does not know that rate. The page calculates it from your ZIP by applying your rate to 615 kWh a year at the very small draw pattern. This model sits 0 kWh from the class median of 615 kWh. At any given rate, its calculated cost therefore matches that of a median unit in its class. You can see the figure for your address in the cost calculator on your own ZIP. The installed price range appears in its own block, with its source and date. It is a modeled installed-cost range, not a quote.

DOE CCD · 2026-09-19

How this compares

The closest models in the same class — same fuel, type and draw pattern.


Keep going