DoesTheMath

KWICKSHOT TEF024V120

0.95 UEF DOE CCD · 2026-09-19
F

Grade F: where this UEF sits among the 271 models in its class, lowest (G) to highest (A). A position, not an official label. How the grade is set

An electric tankless unit, very small draw pattern (small units - a single bathroom, or a point-of-use heater under a sink).

If you are checking the KWICKSHOT TEF024V120, the federal test figure is 622 kWh of electricity a year at the very small draw pattern, the standard daily hot-water usage DOE tests against. That is 7 kWh above the class median of 615 kWh, placing it 152nd lowest of 271 models.


Energy use per year

622 kWh a year

Computed by this site from the registry's UEF and the federal test's daily hot-water draw for this draw pattern. What it costs depends on the electricity rate where you live.

That is above the median of 615 kWh for the 271 models registered in the same heater type and draw pattern; it ranks 152 of 271, lowest energy first.

This model: 622 kWh

Solid line: this model (622 kWh). Dashed line: the class median.

Min 562 kWh Median 615 kWh Max 649 kWh

DOE CCD · 2026-09-19

Report an issue with this number


What it costs to run where you live

Enter your ZIP to see what this unit costs to run a year on your own utility’s electricity rate.


What the registry files

UEF (Uniform Energy Factor) how much hot water you get for each unit of energy the heater uses
0.95 DOE CCD · 2026-09-19 Compared only with other models registered as an electric tankless unit at the very small draw pattern.
Draw Pattern the standard daily usage profile DOE tests the unit against
Very small DOE CCD · 2026-09-19
Maximum Gallons Per Minute how many gallons a minute it can heat while running continuously
0.2 gal/min DOE CCD · 2026-09-19

What it costs to install

$1,303–$1,814 installed

Not a quote — a modeled range of what installers have charged for this class of unit; your price will vary with labor rates, access, and local code requirements.

Escalation indexes: equipment (BLS PPI) latest available: August 2026; labor (BLS ECI) latest available: April 2026 to June 2026.

NLR REMDB (BLS PPI/ECI escalated) · 2026-04-01

Report an issue with this number


Safety record

No CPSC recall names this model.

Checked against the CPSC recall database. CPSC does not publish a model-level match for this product category, so this list is curated by hand from the manufacturer's recall filings.

CPSC · 2026-09-24

What these figures mean

The registry lists this model with a UEF, the ratio of hot water delivered to energy used, of 0.95, and a maximum flow rate in gallons per minute of 0.2. The registry does not publish annual energy. This site computed the figure of 622 kWh from the registry's UEF and the DOE test's daily hot-water draw for the very small draw pattern. The source is DOE CCD, retrieved 2026-09-19. The value applies only at that draw pattern and only to electricity. Hot-water use above the federal test's daily draw would change it, and this page has no figure for such use. The calculation method explains each step.

Among the 271 models registered as an electric tankless unit at the very small draw pattern, this one uses 7 kWh more than the class median of 615 kWh. That places it 152nd lowest for energy use, in the second-highest quarter of its class. The very small draw pattern describes small units: a single bathroom, or a point-of-use heater under a sink. With a maximum flow rate of 0.2 gallons per minute, this listing belongs to that kind of use, and the registry data give no basis for comparing it at higher draws. To see other units in the same class, find a same-class replacement by model number or use the selector by fuel, space and size.

Running cost is not stated here because it depends on your own utility electricity rate. Multiplying the 622 kWh by your rate per kWh gives the yearly cost at the federal test's draw, and your actual draw may differ. The cost calculator does this from your ZIP. Against the class median of 615 kWh, this model's difference is 7 kWh a year at that same draw, priced at your rate. The modeled installed-cost range appears in its own block on this page, with its source and date. It is a modeled range, not a quote, and this text does not combine it with the energy figure.

DOE CCD · 2026-09-19

How this compares

The closest models in the same class — same fuel, type and draw pattern.


Keep going