DoesTheMath

JOHN WOOD ATHR-180M 1**

0.95 UEF DOE CCD · 2026-09-19
B

Grade B: where this UEF sits among the 397 models in its class, lowest (G) to highest (A). A position, not an official label. How the grade is set

A gas tankless unit, high draw pattern (a larger household, or one where showers and laundry overlap).

If you are checking this unit against the registry, JOHN WOOD ATHR-180M 1** uses 178 therms of natural gas a year at the high draw pattern, the standard daily hot-water usage DOE tests against. That is 4 therms below the class median of 182 therms, and it ranks 45th lowest of 397 models.


Energy use per year

178 therms a year

Computed by this site from the registry's UEF and the federal test's daily hot-water draw for this draw pattern. What it costs depends on the natural gas rate where you live.

That is below the median of 182 therms for the 397 models registered in the same heater type and draw pattern; it ranks 45 of 397, lowest energy first.

This model: 178 therms

Solid line: this model (178 therms). Dashed line: the class median.

Min 173 therms Median 182 therms Max 209 therms

DOE CCD · 2026-09-19

Report an issue with this number


What it costs to run where you live

Enter your ZIP to see what this unit costs to run a year at your state’s average natural gas price.


What the registry files

UEF (Uniform Energy Factor) how much hot water you get for each unit of energy the heater uses
0.95 DOE CCD · 2026-09-19 Compared only with other models registered as a gas tankless unit at the high draw pattern.
Draw Pattern the standard daily usage profile DOE tests the unit against
High DOE CCD · 2026-09-19
Maximum Gallons Per Minute how many gallons a minute it can heat while running continuously
5.3 gal/min DOE CCD · 2026-09-19
On the market since (ENERGY STAR) the date the manufacturer told ENERGY STAR the model went on sale
2024-02-01 ENERGY STAR · 2026-09-19
Connected / demand response (ENERGY STAR) whether the unit can take signals from your utility to shift when it heats, and by which standard (such as CTA-2045)
No ENERGY STAR · 2026-09-19

What it costs to install

$2,358–$3,405 installed

Not a quote — a modeled range of what installers have charged for this class of unit; your price will vary with labor rates, access, and local code requirements.

Escalation indexes: equipment (BLS PPI) latest available: August 2026; labor (BLS ECI) latest available: April 2026 to June 2026.

NLR REMDB (BLS PPI/ECI escalated) · 2026-04-01

Report an issue with this number


Safety record

No CPSC recall names this model.

Checked against the CPSC recall database. CPSC does not publish a model-level match for this product category, so this list is curated by hand from the manufacturer's recall filings.

CPSC · 2026-09-24

Does it fit your space?

Enter your own numbers below — this compares them to what ENERGY STAR publishes for this model, it does not tell you what to buy.

Dimensions (ENERGY STAR)
the unit's filed height, width, depth or tank diameter, in inches
Input voltage and maximum current (ENERGY STAR)
the circuit voltage the unit is certified on and the most current it draws
Vent type and size (ENERGY STAR)
how a gas unit is vented, the vent's diameter and the height of its vent connector
  • Physical footprintEnter your numbers27" H × 17" W × 16" D × 1" ⌀
  • Electrical supplyEnter your numbers5A max
  • Vent compatibilityEnter your numbersPower Vent or Power Direct Vent, 3" or 2" vent, 1" to vent
ENERGY STAR · 2026-09-19

What these figures mean

The figure of 178 therms is computed by this site, not the registry. It combines the registry's UEF, the ratio of hot water delivered to energy used, of 0.95 with the DOE test's daily hot-water draw for the high draw pattern. The registry data comes from the DOE CCD, retrieved 2026-09-19. The class is the 397 models registered as a gas tankless unit at this draw pattern, and its median is 182 therms. This model sits 4 therms below that median. That is 45th lowest, in the lowest quarter of its class for energy use. The figure applies to the federal test's draw, not to any particular home's use.

The high draw pattern stands for a larger household, or one where showers and laundry overlap. JOHN WOOD ATHR-180M 1** was compared at that pattern, so its 178 therms is a like-for-like figure for such a household, 4 therms under the class median of 182 therms. The registry lists its maximum flow rate in gallons per minute as 5.3. That is a rated value, and the temperature rise it applies to is not available in this data. The figure does not describe a household with lighter use, because no annual energy value for another draw pattern is available on this page. It also does not apply to other fuels, since it is a natural gas figure. To compare by fuel, space and size, use the water heater selector.

The running cost is not written here because it depends on your state's average residential gas price. Enter your ZIP in the cost calculator to apply that price to 178 therms. The methodology page explains how the annual cost is calculated from the registry's UEF of 0.95 and the test's daily draw. Because the energy figure is a test value at the high draw pattern, a home's own use can differ, and this site does not estimate that difference. The modeled installed-cost range appears in its own block on the page with its source and date, so it is not restated here. To find a same-class unit, search by model number and compare it against the class median of 182 therms.

DOE CCD · 2026-09-19

How this compares

The closest models in the same class — same fuel, type and draw pattern.