JETGLAS RE2HP50**-1NCTT
3.89 UEF DOE CCD · 2026-09-19Grade A: where this UEF sits among the 426 models in its class, lowest (G) to highest (A). A position, not an official label. How the grade is set
An electric tank, medium draw pattern (a typical three- or four-person household, about 55 gallons on a busy morning).
If you are verifying JETGLAS RE2HP50**-1NCTT, an electric tank, it uses 835 kWh a year at the medium draw pattern, the standard daily hot-water usage DOE tests against. That is 2,696 kWh below the class median of 3,531 kWh, and it ranks 3rd lowest of 426.
Energy use per year
835 kWh a year
Computed by this site from the registry's UEF and the federal test's daily hot-water draw for this draw pattern. What it costs depends on the electricity rate where you live.
That is below the median of 3,531 kWh for the 426 models registered in the same heater type and draw pattern; it ranks 3 of 426, lowest energy first.
Solid line: this model (835 kWh). Dashed line: the class median.
Min 773 kWh Median 3,531 kWh Max 3,569 kWh
What it costs to run where you live
What the registry files
- UEF (Uniform Energy Factor) how much hot water you get for each unit of energy the heater uses
- 3.89 DOE CCD · 2026-09-19 Compared only with other models registered as an electric tank at the medium draw pattern.
- Draw Pattern the standard daily usage profile DOE tests the unit against
- Medium DOE CCD · 2026-09-19
- First Hour Rating how many gallons of hot water the unit can deliver in one hour, starting from a full tank
- 65 gal DOE CCD · 2026-09-19
- Rated Storage Volume the tank size in gallons
- 45 gal DOE CCD · 2026-09-19
- On the market since (ENERGY STAR) the date the manufacturer told ENERGY STAR the model went on sale
- 2025-07-16 ENERGY STAR · 2026-09-19
- Connected / demand response (ENERGY STAR) whether the unit can take signals from your utility to shift when it heats, and by which standard (such as CTA-2045)
- No ENERGY STAR · 2026-09-19
- Refrigerant and GWP (ENERGY STAR) the refrigerant a heat pump unit uses and its global warming potential, a leak's climate effect relative to carbon dioxide (CO2 = 1)
- R-134a, GWP 1430 ENERGY STAR · 2026-09-19
What it costs to install
$3,040–$4,540 installed
Not a quote — a modeled range of what installers have charged for this class of unit; your price will vary with labor rates, access, and local code requirements.
Escalation indexes: equipment (BLS PPI) latest available: August 2026; labor (BLS ECI) latest available: April 2026 to June 2026.
NLR REMDB (BLS PPI/ECI escalated) · 2026-04-01Safety record
No CPSC recall names this model.
Checked against the CPSC recall database. CPSC does not publish a model-level match for this product category, so this list is curated by hand from the manufacturer's recall filings.
CPSC · 2026-09-24Does it fit your space?
Enter your own numbers below — this compares them to what ENERGY STAR publishes for this model, it does not tell you what to buy.
- Compressor operating range (ENERGY STAR)
- the air temperatures around the unit in which its heat pump runs; outside this range the heat pump stops
- Dimensions (ENERGY STAR)
- the unit's filed height, width, depth or tank diameter, in inches
- Input voltage and maximum current (ENERGY STAR)
- the circuit voltage the unit is certified on and the most current it draws
What these figures mean
How this compares
The closest models in the same class — same fuel, type and draw pattern.
Keep going
How every figure on this page is calculated
-
Find what replaces your water heater
Enter the model number off your old unit and see what is on file today, with the yearly cost difference.
-
Find a water heater that fits
Three questions — fuel, hot water need, install space — narrow every model on file to the ones that fit.
-
What a water heater costs to run
Prices a unit's efficiency against your own utility's filed tariff for your ZIP code.
-
What size heat pump water heater do I need?
Answered from what models in this size actually file.
-
Water heaters
Every model on file with the Department of Energy, by heater type.
-
All heat pump water heaters
Electric tanks that file a UEF of 2.0 or more — the registry has no separate heat pump type, so this site draws the line there.
-
Every JETGLAS model on file
What this brand files, by heater type.
UEF 3.89 · Grade A Price it on your ZIP
The figure of 835 kWh is a calculation by this site, not a value published by the registry. It combines the registry's UEF, the ratio of hot water delivered to energy used, which is 3.89 for this model, with the daily hot-water draw the DOE test assigns to the medium draw pattern. The fuel is electricity, and the source is DOE CCD, retrieved 2026-09-19. The comparison group is the 426 models registered as an electric tank at this draw pattern, and their median is 3,531 kWh. This model sits 2,696 kWh below that median. Its rank of 3rd lowest energy use of 426 places it in the lowest quarter of its class. The comparison holds only for electric tanks at the medium draw pattern.
The registry lists a first hour rating, the gallons of hot water available in the first hour from a full tank, of 65 gallons, and a rated volume of 45 gallons. The energy figure fits a household whose hot-water use resembles the medium draw pattern, a typical three- or four-person household on a busy morning. It does not describe a household that draws clearly more or less than the test's daily amount, because the figure is tied to that test draw. This page has no figures for other draw patterns, so they are not available here. If you are unsure which fuel, space and size suit your home, the water heater selector sorts models on those three points. A low energy figure does not show whether the tank meets your own hot-water demand.
The running cost is not stated in the text because it depends on your own utility electricity tariff. The cost calculator applies your rate, taken from your ZIP, to the 835 kWh at the medium draw pattern. The steps are set out in how the annual cost is calculated. Because 835 kWh is 2,696 kWh below the class median of 3,531 kWh, the same rate applied to the median would give a higher cost, and the exact gap depends on that rate. The installed price appears in its own block as a modeled range, not a quote. To compare against another unit of the same class, find a same-class replacement by model number. Measured use in your own home is not available and may differ from the test.
DOE CCD · 2026-09-19