DoesTheMath

HUBBELL MP120F

0.9 UEF DOE CCD · 2026-09-19
G

Grade G: where this UEF sits among the 21 models in its class, lowest (G) to highest (A). A position, not an official label. How the grade is set

An electric tank your utility can shift to off-peak hours, high draw pattern (a larger household, or one where showers and laundry overlap).

If you are checking the HUBBELL MP120F: it uses 5,512 kWh of electricity a year at the high draw pattern, the standard daily hot-water usage DOE tests against. That is 120 kWh above the class median of 5,392 kWh, ranking 16th lowest of 21 electric tanks your utility can shift to off-peak hours.


Energy use per year

5,512 kWh a year

Computed by this site from the registry's UEF and the federal test's daily hot-water draw for this draw pattern. What it costs depends on the electricity rate where you live.

That is above the median of 5,392 kWh for the 21 models registered in the same heater type and draw pattern; it ranks 16 of 21, lowest energy first.

This model: 5,512 kWh

Solid line: this model (5,512 kWh). Dashed line: the class median.

Min 5,334 kWh Median 5,392 kWh Max 5,512 kWh

DOE CCD · 2026-09-19

Report an issue with this number


What it costs to run where you live

Enter your ZIP to see what this unit costs to run a year on your own utility’s electricity rate.


What the registry files

UEF (Uniform Energy Factor) how much hot water you get for each unit of energy the heater uses
0.9 DOE CCD · 2026-09-19 Compared only with other models registered as an electric tank your utility can shift to off-peak hours at the high draw pattern.
Draw Pattern the standard daily usage profile DOE tests the unit against
High DOE CCD · 2026-09-19
First Hour Rating how many gallons of hot water the unit can deliver in one hour, starting from a full tank
117 gal DOE CCD · 2026-09-19
Rated Storage Volume the tank size in gallons
119 gal DOE CCD · 2026-09-19

What it costs to install

Not published: Installed cost range

This model's UEF lies outside the range NLR REMDB's cost model was fitted on, and the range is not stretched past it.

The annual energy figure on this page does not depend on this range and is unaffected.


Safety record

No CPSC recall names this model.

Checked against the CPSC recall database. CPSC does not publish a model-level match for this product category, so this list is curated by hand from the manufacturer's recall filings.

CPSC · 2026-09-24

What these figures mean

This site computes the 5,512 kWh figure; the registry does not publish it. The inputs are the registry's UEF, the ratio of hot water delivered to energy used, of 0.9, and the DOE test's daily hot-water draw for the high draw pattern. The source is the DOE CCD, retrieved 2026-09-19. The figure holds only at that test draw. A home whose daily hot-water use differs from the test's will not match 5,512 kWh, and this page does not have that home's own figure. The same condition applies to the class median of 5,392 kWh, so the 120 kWh gap is measured at one test draw. It is a rated difference, not a metered one. The method behind the annual energy and cost figures lists these inputs in order.

The high draw pattern stands for a larger household, or one where showers and laundry overlap. This tank holds 119 gallons. Its first hour rating, the gallons of hot water available in the first hour from a full tank, is 117 gallons. A household with light daily use falls outside the draw pattern behind the 5,512 kWh figure, so that figure does not describe it. Within its class, the rank given above places this model in the second-highest quarter for energy use. This data does not show whether a particular home's peak use fits within 117 gallons. If you are matching a unit already installed, you can find a same-class replacement by model number.

The text does not state a running cost because it depends on your own utility's electricity tariff. The page computes it from your ZIP and the 5,512 kWh figure. The 120 kWh above the class median is priced at that same local rate. As an electric tank your utility can shift to off-peak hours, its cost may also depend on how your tariff prices those hours. This data does not show that. An installed price range is not published for this model. Its ratings lie outside the range the cost database's model was fitted on, and the range is not stretched past it. For the running cost at your own rate, use the cost calculator on your own ZIP.

DOE CCD · 2026-09-19

How this compares

The closest models in the same class — same fuel, type and draw pattern.


Keep going

UEF 0.9 · Grade G Price it on your ZIP