HTP EVG-100******
0.93 UEF DOE CCD · 2026-09-19Grade A: where this UEF sits among the 21 models in its class, lowest (G) to highest (A). A position, not an official label. How the grade is set
An electric tank your utility can shift to off-peak hours, high draw pattern (a larger household, or one where showers and laundry overlap).
Checking a listing? The HTP EVG-100****** uses 5,334 kWh of electricity a year at the high draw pattern, the standard daily hot-water usage DOE tests against. It is 58 kWh below the class median of 5,392 kWh, and it ranks 1st lowest of 21 models.
Energy use per year
5,334 kWh a year
Computed by this site from the registry's UEF and the federal test's daily hot-water draw for this draw pattern. What it costs depends on the electricity rate where you live.
That is below the median of 5,392 kWh for the 21 models registered in the same heater type and draw pattern; it ranks 1 of 21, lowest energy first.
Solid line: this model (5,334 kWh). Dashed line: the class median.
Min 5,334 kWh Median 5,392 kWh Max 5,512 kWh
What it costs to run where you live
What the registry files
- UEF (Uniform Energy Factor) how much hot water you get for each unit of energy the heater uses
- 0.93 DOE CCD · 2026-09-19 Compared only with other models registered as an electric tank your utility can shift to off-peak hours at the high draw pattern.
- Draw Pattern the standard daily usage profile DOE tests the unit against
- High DOE CCD · 2026-09-19
- First Hour Rating how many gallons of hot water the unit can deliver in one hour, starting from a full tank
- 86 gal DOE CCD · 2026-09-19
- Rated Storage Volume the tank size in gallons
- 96 gal DOE CCD · 2026-09-19
What it costs to install
Not published: Installed cost range
This model's rated tank size lies outside the range NLR REMDB's cost model was fitted on, and the range is not stretched past it.
The annual energy figure on this page does not depend on this range and is unaffected.
Safety record
No CPSC recall names this model.
Checked against the CPSC recall database. CPSC does not publish a model-level match for this product category, so this list is curated by hand from the manufacturer's recall filings.
CPSC · 2026-09-24What these figures mean
How this compares
The closest models in the same class — same fuel, type and draw pattern.
Keep going
How every figure on this page is calculated
-
Find what replaces your water heater
Enter the model number off your old unit and see what is on file today, with the yearly cost difference.
-
Find a water heater that fits
Three questions — fuel, hot water need, install space — narrow every model on file to the ones that fit.
-
What a water heater costs to run
Prices a unit's efficiency against your own utility's filed tariff for your ZIP code.
-
Water heaters
Every model on file with the Department of Energy, by heater type.
-
Every HTP model on file
What this brand files, by heater type.
UEF 0.93 · Grade A Price it on your ZIP
This figure was computed by this site, not taken from the registry. It uses the registry's UEF, the ratio of hot water delivered to energy used, which is 0.93 for this model. It also uses the DOE test's daily hot-water draw for the high draw pattern. The result is 5,334 kWh of electricity a year. It applies only at that test draw, so a household with different use will see a different total. The source is DOE CCD, retrieved 2026-09-19. The class is the 21 models registered as an electric tank your utility can shift to off-peak hours. Their median at the high draw pattern is 5,392 kWh. This model is 58 kWh below that median, which puts it in the lowest quarter of its class for energy use.
The high draw pattern is a larger household, or one where showers and laundry overlap. The figure of 5,334 kWh was computed at that draw, so it fits that case. The first hour rating, the gallons of hot water available in the first hour from a full tank, is 86 gallons. The rated volume is 96 gallons. The registry data does not show whether those gallons cover any one home's busiest hour. A household with a lower draw is outside the condition of this figure, and this page gives no figure for other draw patterns. To compare by fuel, space and size, use the water heater selector. To look for a unit in the same class, try the same-class replacement finder with a model number.
The running cost is not stated here because it depends on your own utility electricity tariff. Multiplying 5,334 kWh by your rate gives the yearly electricity cost at the test draw. The cost calculator on your own ZIP does this for you. The method is set out in how the annual cost is calculated. An installed price range is not published for this model. Its ratings lie outside the range the cost database's model was fitted on, and the range is not stretched past it. The rank of 1st lowest of 21 concerns energy use only. It says nothing about price.
DOE CCD · 2026-09-19