DoesTheMath

GREE GRS-3.0Pd/TD50GANhA-D

4.02 UEF DOE CCD · 2026-09-19
B

Grade B: where this UEF sits among the 194 models in its class, lowest (G) to highest (A). A position, not an official label. How the grade is set

An electric tank, high draw pattern (a larger household, or one where showers and laundry overlap).

If you are checking the GREE GRS-3.0Pd/TD50GANhA-D, an electric tank water heater, it uses 1,234 kWh of electricity a year. That figure belongs to the high draw pattern, the standard daily hot-water usage DOE tests against. It sits 72 kWh below the 1,306 kWh median of the 194 electric tank models registered at that draw pattern.


Energy use per year

1,234 kWh a year

Computed by this site from the registry's UEF and the federal test's daily hot-water draw for this draw pattern. What it costs depends on the electricity rate where you live.

That is below the median of 1,306 kWh for the 194 models registered in the same heater type and draw pattern; it ranks 27 of 194, lowest energy first.

This model: 1,234 kWh

Solid line: this model (1,234 kWh). Dashed line: the class median.

Min 1,002 kWh Median 1,306 kWh Max 5,334 kWh

DOE CCD · 2026-09-19

Report an issue with this number


What it costs to run where you live

Enter your ZIP to see what this unit costs to run a year on your own utility’s electricity rate.


What the registry files

UEF (Uniform Energy Factor) how much hot water you get for each unit of energy the heater uses
4.02 DOE CCD · 2026-09-19 Compared only with other models registered as an electric tank at the high draw pattern.
Draw Pattern the standard daily usage profile DOE tests the unit against
High DOE CCD · 2026-09-19
First Hour Rating how many gallons of hot water the unit can deliver in one hour, starting from a full tank
80 gal DOE CCD · 2026-09-19
Rated Storage Volume the tank size in gallons
55 gal DOE CCD · 2026-09-19
On the market since (ENERGY STAR) the date the manufacturer told ENERGY STAR the model went on sale
2025-11-17 ENERGY STAR · 2026-09-19
Connected / demand response (ENERGY STAR) whether the unit can take signals from your utility to shift when it heats, and by which standard (such as CTA-2045)
No ENERGY STAR · 2026-09-19
Refrigerant and GWP (ENERGY STAR) the refrigerant a heat pump unit uses and its global warming potential, a leak's climate effect relative to carbon dioxide (CO2 = 1)
R-32 ENERGY STAR · 2026-09-19

What it costs to install

$3,380–$4,764 installed

Not a quote — a modeled range of what installers have charged for this class of unit; your price will vary with labor rates, access, and local code requirements.

Escalation indexes: equipment (BLS PPI) latest available: August 2026; labor (BLS ECI) latest available: April 2026 to June 2026.

NLR REMDB (BLS PPI/ECI escalated) · 2026-04-01

Report an issue with this number


Safety record

No CPSC recall names this model.

Checked against the CPSC recall database. CPSC does not publish a model-level match for this product category, so this list is curated by hand from the manufacturer's recall filings.

CPSC · 2026-09-24

Does it fit your space?

Enter your own numbers below — this compares them to what ENERGY STAR publishes for this model, it does not tell you what to buy.

Compressor operating range (ENERGY STAR)
the air temperatures around the unit in which its heat pump runs; outside this range the heat pump stops
Dimensions (ENERGY STAR)
the unit's filed height, width, depth or tank diameter, in inches
Input voltage and maximum current (ENERGY STAR)
the circuit voltage the unit is certified on and the most current it draws
  • Ambient temperatureEnter your numbers35.6°F min, 113°F max
  • Physical footprintEnter your numbers25.2" ⌀
  • Electrical supplyEnter your numbers240V, 23.9A max
ENERGY STAR · 2026-09-19

What these figures mean

This site computed the 1,234 kWh figure; the registry does not list it. The calculation combines the model's UEF, the ratio of hot water delivered to energy used, with the DOE test's daily hot-water draw for the high draw pattern. The registry lists a UEF of 4.02 for this model in DOE CCD data retrieved 2026-09-19. This model ranks 27th lowest for energy use among the 194 electric tank models at the high draw pattern. That rank puts it in the lowest quarter of its class. The figure holds only at the test's draw. A household that uses more or less hot water will use a different amount of electricity. The page on how the annual figure is calculated explains each input.

The high draw pattern describes a larger household, or one where showers and laundry overlap. This model's first hour rating, the gallons of hot water available in the first hour from a full tank, is 80 gallons. Its rated volume is 55 gallons. The 1,234 kWh figure applies to a home with that level of overlapping demand. The test does not cover a smaller household with lighter use, so no annual energy figure for that case is available here. The registry data also does not show how the unit performs outside the federal test conditions. To compare other units by fuel, space and size, use the water heater selector. To find other models in this class, use the same-class replacement search by model number.

The text on this page gives no running cost because that cost depends on your own utility electricity tariff. Instead, the page computes it from your ZIP, using the 1,234 kWh figure at the high draw pattern. The same applies to the 72 kWh gap below the class median of 1,306 kWh. What that gap saves you depends on your rate, and this page does not estimate it. You can see that cost in the cost calculator for your ZIP. The installed price range appears in its own block on this page, with its own source and date. It is a modeled installed-cost range, not a quote. Plumbers and sellers can check the 4.02 UEF and the 80-gallon first hour rating against the registry entry.

DOE CCD · 2026-09-19

How this compares

The closest models in the same class — same fuel, type and draw pattern.


Keep going

UEF 4.02 · Grade B Price it on your ZIP