DoesTheMath

GE Profile PH65S10BPY01

4.3 UEF DOE CCD · 2026-09-19
B

Grade B: where this UEF sits among the 194 models in its class, lowest (G) to highest (A). A position, not an official label. How the grade is set

An electric tank, high draw pattern (a larger household, or one where showers and laundry overlap).

You are checking the energy figure for the GE Profile PH65S10BPY01. It uses 1,154 kWh a year at the high draw pattern, the standard daily hot-water usage DOE tests against. That is 152 kWh below the class median of 1,306 kWh for 194 electric tank models.


Energy use per year

1,154 kWh a year

Computed by this site from the registry's UEF and the federal test's daily hot-water draw for this draw pattern. What it costs depends on the electricity rate where you live.

That is below the median of 1,306 kWh for the 194 models registered in the same heater type and draw pattern; it ranks 5 of 194, lowest energy first.

This model: 1,154 kWh

Solid line: this model (1,154 kWh). Dashed line: the class median.

Min 1,002 kWh Median 1,306 kWh Max 5,334 kWh

DOE CCD · 2026-09-19

Report an issue with this number


What it costs to run where you live

Enter your ZIP to see what this unit costs to run a year on your own utility’s electricity rate.


What the registry files

UEF (Uniform Energy Factor) how much hot water you get for each unit of energy the heater uses
4.3 DOE CCD · 2026-09-19 Compared only with other models registered as an electric tank at the high draw pattern.
Draw Pattern the standard daily usage profile DOE tests the unit against
High DOE CCD · 2026-09-19
First Hour Rating how many gallons of hot water the unit can deliver in one hour, starting from a full tank
87 gal DOE CCD · 2026-09-19
Rated Storage Volume the tank size in gallons
65 gal DOE CCD · 2026-09-19
On the market since (ENERGY STAR) the date the manufacturer told ENERGY STAR the model went on sale
2025-07-23 ENERGY STAR · 2026-09-19
Connected / demand response (ENERGY STAR) whether the unit can take signals from your utility to shift when it heats, and by which standard (such as CTA-2045)
Yes (CTA-2045-A,CTA-2045-B) ENERGY STAR · 2026-09-19
Refrigerant and GWP (ENERGY STAR) the refrigerant a heat pump unit uses and its global warming potential, a leak's climate effect relative to carbon dioxide (CO2 = 1)
R1234YF ENERGY STAR · 2026-09-19
Sound level (ENERGY STAR) how loud the unit is while it runs, in decibels as filed
41 dB ENERGY STAR · 2026-09-19

What it costs to install

Not published: Installed cost range

This model's UEF lies outside the range NLR REMDB's cost model was fitted on, and the range is not stretched past it.

The annual energy figure on this page does not depend on this range and is unaffected.


Safety record

No CPSC recall names this model.

Checked against the CPSC recall database. CPSC does not publish a model-level match for this product category, so this list is curated by hand from the manufacturer's recall filings.

CPSC · 2026-09-24

Does it fit your space?

Enter your own numbers below — this compares them to what ENERGY STAR publishes for this model, it does not tell you what to buy.

Compressor operating range (ENERGY STAR)
the air temperatures around the unit in which its heat pump runs; outside this range the heat pump stops
Dimensions (ENERGY STAR)
the unit's filed height, width, depth or tank diameter, in inches
Input voltage and maximum current (ENERGY STAR)
the circuit voltage the unit is certified on and the most current it draws
  • Ambient temperatureEnter your numbers35°F min
  • Physical footprintEnter your numbers21.5" ⌀
  • Electrical supplyEnter your numbers240V, 23A max
ENERGY STAR · 2026-09-19

What these figures mean

The figure of 1,154 kWh is computed by this site, not by the registry. It starts from the registry's UEF, the ratio of hot water delivered to energy used. This model's UEF is 4.3. The site applies it to the DOE test's daily hot-water draw for the high draw pattern. The source is DOE CCD, retrieved 2026-09-19. Among 194 electric tank models at this draw pattern, the model ranks 5th lowest for energy use. That places it in the lowest quarter of its class. The gap to the median is 152 kWh, against a median of 1,306 kWh. Your own use may differ from the federal test's draw, so the figure is a basis for comparison and not a forecast of your meter reading. The steps behind it are set out in how the annual cost is calculated.

The high draw pattern describes a larger household, or one where showers and laundry overlap. The first hour rating, the gallons of hot water available in the first hour from a full tank, is 87 gallons for this model. The rated volume is 65 gallons. Compare these two ratings with your own busiest hour of hot-water demand. The energy figure applies to a household that matches the high draw pattern. It does not describe a household with a lower daily draw, because the figure is tied to this one pattern. Energy use at other draw patterns is not available on this page. Whether the tank fits your space is a separate question, and the selector by fuel, space and size covers it.

The running cost is not stated here because it depends on your utility's electricity tariff. Multiply 1,154 kWh by your rate per kWh to get a yearly cost at the federal test's draw. The cost calculator on your own ZIP does this with your local rate. Any result carries the same condition as the energy figure, which is the high draw pattern. A household with different use will see a different total. An installed price range is not published for this model. Its ratings lie outside the range the cost database's model was fitted on. The range is not stretched past that limit. To look at other units in the same class, find a same-class replacement by model number using PH65S10BPY01.

DOE CCD · 2026-09-19

How this compares

The closest models in the same class — same fuel, type and draw pattern.


Keep going

UEF 4.3 · Grade B Price it on your ZIP