FRIEDRICH XE55T12CS55U0
0.92 UEF DOE CCD · 2026-09-19Grade G: where this UEF sits among the 426 models in its class, lowest (G) to highest (A). A position, not an official label. How the grade is set
An electric tank, medium draw pattern (a typical three- or four-person household, about 55 gallons on a busy morning).
If you are checking the FRIEDRICH XE55T12CS55U0, it uses 3,531 kWh of electricity a year at the medium draw pattern, the standard daily hot-water usage DOE tests against. That equals its class median of 3,531 kWh, a difference of 0 kWh, among 426 electric tank models.
Energy use per year
3,531 kWh a year
Computed by this site from the registry's UEF and the federal test's daily hot-water draw for this draw pattern. What it costs depends on the electricity rate where you live.
That is equal to the median of 3,531 kWh for the 426 models registered in the same heater type and draw pattern; it ranks 213 of 426, lowest energy first.
Solid line: this model (3,531 kWh). Dashed line: the class median.
Min 773 kWh Median 3,531 kWh Max 3,569 kWh
What it costs to run where you live
What the registry files
- UEF (Uniform Energy Factor) how much hot water you get for each unit of energy the heater uses
- 0.92 DOE CCD · 2026-09-19 Compared only with other models registered as an electric tank at the medium draw pattern.
- Draw Pattern the standard daily usage profile DOE tests the unit against
- Medium DOE CCD · 2026-09-19
- First Hour Rating how many gallons of hot water the unit can deliver in one hour, starting from a full tank
- 74 gal DOE CCD · 2026-09-19
- Rated Storage Volume the tank size in gallons
- 55 gal DOE CCD · 2026-09-19
What it costs to install
$1,866–$2,279 installed
Not a quote — a modeled range of what installers have charged for this class of unit; your price will vary with labor rates, access, and local code requirements.
Escalation indexes: equipment (BLS PPI) latest available: August 2026; labor (BLS ECI) latest available: April 2026 to June 2026.
NLR REMDB (BLS PPI/ECI escalated) · 2026-04-01Safety record
No CPSC recall names this model.
Checked against the CPSC recall database. CPSC does not publish a model-level match for this product category, so this list is curated by hand from the manufacturer's recall filings.
CPSC · 2026-09-24What these figures mean
How this compares
The closest models in the same class — same fuel, type and draw pattern.
Keep going
How every figure on this page is calculated
-
Find what replaces your water heater
Enter the model number off your old unit and see what is on file today, with the yearly cost difference.
-
Find a water heater that fits
Three questions — fuel, hot water need, install space — narrow every model on file to the ones that fit.
-
What a water heater costs to run
Prices a unit's efficiency against your own utility's filed tariff for your ZIP code.
-
Is a 50-gallon water heater enough?
Answered from what models in this size actually file.
-
Water heaters
Every model on file with the Department of Energy, by heater type.
-
All electric resistance tank water heaters
Electric tanks that file a UEF below 2.0 — heated by elements, not a heat pump.
-
Every FRIEDRICH model on file
What this brand files, by heater type.
UEF 0.92 · Grade G Price it on your ZIP
The registry lists this unit with a UEF, the ratio of hot water delivered to energy used, of 0.92. The registry does not publish an annual energy figure, so this site computed 3,531 kWh from that UEF and the DOE test's daily hot-water draw for the medium draw pattern. The source is DOE CCD, retrieved 2026-09-19, and the figure covers electricity only. The class is the 426 models registered as an electric tank at the medium draw pattern. Its median is 3,531 kWh, so this unit differs from it by 0 kWh. It has the 213th lowest energy use of 426, which places it in the second-lowest quarter of its class. The calculation method explains how the figure is derived.
The listing gives a first hour rating, the gallons of hot water available in the first hour from a full tank, of 74 gallons, and a rated volume of 55 gallons. The medium draw pattern represents a typical household on a busy morning. A household whose use resembles that pattern can compare 3,531 kWh directly with the other 426 models in the class. A household that uses noticeably more or less hot water than the test assumes will see a different yearly figure, and this page has no value for other draw patterns. The rank of 213th lowest concerns energy use only; it does not measure whether the tank meets peak demand. The water heater selector filters by fuel, space and size.
Running cost is not written here because it depends on your own utility electricity rate, and this page does not estimate it. The calculation multiplies 3,531 kWh by that rate, and the cost calculator does this from your ZIP. At the same rate, a model at the class median of 3,531 kWh would cost the same to run, since the difference is 0 kWh. The energy figure assumes the medium draw pattern, so actual use in a home can differ from the test's daily draw. The installed price range appears in its own block with its source and date, as a modeled range and not a quote. To look for a same-class alternative, search by model number using XE55T12CS55U0.
DOE CCD · 2026-09-19