FRIEDRICH XE50M12CS55U1
0.92 UEF DOE CCD · 2026-09-19Grade G: where this UEF sits among the 426 models in its class, lowest (G) to highest (A). A position, not an official label. How the grade is set
An electric tank, medium draw pattern (a typical three- or four-person household, about 55 gallons on a busy morning).
Checking the FRIEDRICH XE50M12CS55U1? This electric tank uses 3,531 kWh a year at the medium draw pattern, the standard daily hot-water usage DOE tests against. That is 0 kWh from the class median of 3,531 kWh across 426 models, so it sits at the median.
Energy use per year
3,531 kWh a year
Computed by this site from the registry's UEF and the federal test's daily hot-water draw for this draw pattern. What it costs depends on the electricity rate where you live.
That is equal to the median of 3,531 kWh for the 426 models registered in the same heater type and draw pattern; it ranks 213 of 426, lowest energy first.
Solid line: this model (3,531 kWh). Dashed line: the class median.
Min 773 kWh Median 3,531 kWh Max 3,569 kWh
What it costs to run where you live
What the registry files
- UEF (Uniform Energy Factor) how much hot water you get for each unit of energy the heater uses
- 0.92 DOE CCD · 2026-09-19 Compared only with other models registered as an electric tank at the medium draw pattern.
- Draw Pattern the standard daily usage profile DOE tests the unit against
- Medium DOE CCD · 2026-09-19
- First Hour Rating how many gallons of hot water the unit can deliver in one hour, starting from a full tank
- 63 gal DOE CCD · 2026-09-19
- Rated Storage Volume the tank size in gallons
- 45 gal DOE CCD · 2026-09-19
What it costs to install
$1,721–$2,028 installed
Not a quote — a modeled range of what installers have charged for this class of unit; your price will vary with labor rates, access, and local code requirements.
Escalation indexes: equipment (BLS PPI) latest available: August 2026; labor (BLS ECI) latest available: April 2026 to June 2026.
NLR REMDB (BLS PPI/ECI escalated) · 2026-04-01Safety record
No CPSC recall names this model.
Checked against the CPSC recall database. CPSC does not publish a model-level match for this product category, so this list is curated by hand from the manufacturer's recall filings.
CPSC · 2026-09-24What these figures mean
How this compares
The closest models in the same class — same fuel, type and draw pattern.
Keep going
How every figure on this page is calculated
-
Find what replaces your water heater
Enter the model number off your old unit and see what is on file today, with the yearly cost difference.
-
Find a water heater that fits
Three questions — fuel, hot water need, install space — narrow every model on file to the ones that fit.
-
What a water heater costs to run
Prices a unit's efficiency against your own utility's filed tariff for your ZIP code.
-
Is a 40-gallon water heater enough?
Answered from what models in this size actually file.
-
Water heaters
Every model on file with the Department of Energy, by heater type.
-
All electric resistance tank water heaters
Electric tanks that file a UEF below 2.0 — heated by elements, not a heat pump.
-
Every FRIEDRICH model on file
What this brand files, by heater type.
UEF 0.92 · Grade G Price it on your ZIP
The registry lists a UEF, the ratio of hot water delivered to energy used, of 0.92 for this model. This site multiplied that UEF by the daily hot-water draw the DOE test assigns to the medium draw pattern. The result is 3,531 kWh of electricity a year. The registry does not publish that annual figure itself. It is computed here from DOE CCD data retrieved on 2026-09-19. The figure holds only at the test draw. A household that uses more or less hot water than the test assumes will see a different total, and the data does not say by how much. The steps are set out in how the annual cost is calculated.
Among the 426 models registered as an electric tank at the medium draw pattern, this unit ranks 213th lowest for energy use. Its 3,531 kWh equals the class median of 3,531 kWh, a difference of 0 kWh, which places it in the second-lowest quarter of its class. The rank compares energy use at the test draw only. It says nothing about capacity. The first hour rating, the gallons of hot water available in the first hour from a full tank, is 63 gallons, and the rated volume is 45 gallons. The data does not show how those two values compare with the class. To check size against your space, use the selector by fuel, space and size, or find a same-class replacement by model number.
The running cost is not stated here because it depends on your own utility electricity rate. Multiplying 3,531 kWh by your rate per kWh gives the yearly cost at the medium draw pattern. The cost calculator on your own ZIP does this for you. This model suits a household whose hot-water use is close to the test draw and whose target is energy use at the class median of 3,531 kWh. It suits less well a household whose use differs widely from the test draw, because the annual figure is tied to that draw. The installed price appears in its own block as a modeled range with its source and date. It is not a quote.
DOE CCD · 2026-09-19