FRIEDRICH PROE28 S2 RH95
0.92 UEF DOE CCD · 2026-09-19Grade G: where this UEF sits among the 163 models in its class, lowest (G) to highest (A). A position, not an official label. How the grade is set
An electric tank, low draw pattern (a one- or two-person household).
If you are verifying the FRIEDRICH PROE28 S2 RH95, an electric tank, it uses 2,439 kWh of electricity a year at the low draw pattern, the standard daily hot-water usage DOE tests against. The figure is computed by this site from registry data. It is 0 kWh from the class median of 2,439 kWh across 163 registered models.
Energy use per year
2,439 kWh a year
Computed by this site from the registry's UEF and the federal test's daily hot-water draw for this draw pattern. What it costs depends on the electricity rate where you live.
That is equal to the median of 2,439 kWh for the 163 models registered in the same heater type and draw pattern; it ranks 19 of 163, lowest energy first.
Solid line: this model (2,439 kWh). Dashed line: the class median.
Min 724 kWh Median 2,439 kWh Max 2,550 kWh
What it costs to run where you live
What the registry files
- UEF (Uniform Energy Factor) how much hot water you get for each unit of energy the heater uses
- 0.92 DOE CCD · 2026-09-19 Compared only with other models registered as an electric tank at the low draw pattern.
- Draw Pattern the standard daily usage profile DOE tests the unit against
- Low DOE CCD · 2026-09-19
- First Hour Rating how many gallons of hot water the unit can deliver in one hour, starting from a full tank
- 45 gal DOE CCD · 2026-09-19
- Rated Storage Volume the tank size in gallons
- 25 gal DOE CCD · 2026-09-19
What it costs to install
Not published: Installed cost range
This model's rated tank size lies outside the range NLR REMDB's cost model was fitted on, and the range is not stretched past it.
The annual energy figure on this page does not depend on this range and is unaffected.
Safety record
No CPSC recall names this model.
Checked against the CPSC recall database. CPSC does not publish a model-level match for this product category, so this list is curated by hand from the manufacturer's recall filings.
CPSC · 2026-09-24What these figures mean
How this compares
The closest models in the same class — same fuel, type and draw pattern.
Keep going
How every figure on this page is calculated
-
Find what replaces your water heater
Enter the model number off your old unit and see what is on file today, with the yearly cost difference.
-
Find a water heater that fits
Three questions — fuel, hot water need, install space — narrow every model on file to the ones that fit.
-
What a water heater costs to run
Prices a unit's efficiency against your own utility's filed tariff for your ZIP code.
-
Is a 30-gallon water heater enough?
Answered from what models in this size actually file.
-
Water heaters
Every model on file with the Department of Energy, by heater type.
-
All electric resistance tank water heaters
Electric tanks that file a UEF below 2.0 — heated by elements, not a heat pump.
-
Every FRIEDRICH model on file
What this brand files, by heater type.
UEF 0.92 · Grade G Price it on your ZIP
The 2,439 kWh figure starts from the registry's UEF, the ratio of hot water delivered to energy used, which is 0.92 for this model. This site combines that UEF with the federal test's daily hot-water draw for the low draw pattern. The registry does not publish the annual figure itself. The energy data comes from DOE CCD, retrieved 2026-09-19. The result describes the test's daily draw only, so a home that draws more or less hot water than the test will use a different amount. The actual daily draw of your home is not available here. The methodology page sets out the calculation.
The class here is the 163 models registered as an electric tank at the low draw pattern. Their median is 2,439 kWh, and this model differs from it by 0 kWh. The registry comparison also ranks it 19th lowest energy use of 163, which places it in the lowest quarter of its class. The data supplied does not show why a median-equal figure and a lowest-quarter rank appear together, so both are reported as given. The rated volume is 25 gallons, and the first hour rating, the gallons of hot water available in the first hour from a full tank, is 45 gallons. A household whose peak-hour demand exceeds that rating is not served by these figures; the water heater selector filters by fuel, space and size.
The running cost is not stated in this text because it depends on your own utility electricity tariff. Multiplying 2,439 kWh by your rate gives the yearly cost for the low draw pattern, and the cost calculator does this from your ZIP. The installed price range is not published for this model. Its ratings lie outside the range the cost database's model was fitted on, and the range is not stretched past it. If you are checking a like-for-like swap for PROE28 S2 RH95, the replacement finder searches for a same-class unit by model number.
DOE CCD · 2026-09-19