EEMAX SPEX95T
0.98 UEF DOE CCD · 2026-09-19Grade D: where this UEF sits among the 271 models in its class, lowest (G) to highest (A). A position, not an official label. How the grade is set
An electric tankless unit, very small draw pattern (small units - a single bathroom, or a point-of-use heater under a sink).
If you are checking the EEMAX SPEX95T, the figure to verify is 603 kWh of electricity a year at the very small draw pattern, the standard daily hot-water usage DOE tests against. That is 12 kWh below the class median of 615 kWh, and it ranks 10th lowest of 271 models.
Energy use per year
603 kWh a year
Computed by this site from the registry's UEF and the federal test's daily hot-water draw for this draw pattern. What it costs depends on the electricity rate where you live.
That is below the median of 615 kWh for the 271 models registered in the same heater type and draw pattern; it ranks 10 of 271, lowest energy first.
Solid line: this model (603 kWh). Dashed line: the class median.
Min 562 kWh Median 615 kWh Max 649 kWh
What it costs to run where you live
What the registry files
- UEF (Uniform Energy Factor) how much hot water you get for each unit of energy the heater uses
- 0.98 DOE CCD · 2026-09-19 Compared only with other models registered as an electric tankless unit at the very small draw pattern.
- Draw Pattern the standard daily usage profile DOE tests the unit against
- Very small DOE CCD · 2026-09-19
- Maximum Gallons Per Minute how many gallons a minute it can heat while running continuously
- 0.9 gal/min DOE CCD · 2026-09-19
What it costs to install
$1,311–$1,886 installed
Not a quote — a modeled range of what installers have charged for this class of unit; your price will vary with labor rates, access, and local code requirements.
Escalation indexes: equipment (BLS PPI) latest available: August 2026; labor (BLS ECI) latest available: April 2026 to June 2026.
NLR REMDB (BLS PPI/ECI escalated) · 2026-04-01Safety record
No CPSC recall names this model.
Checked against the CPSC recall database. CPSC does not publish a model-level match for this product category, so this list is curated by hand from the manufacturer's recall filings.
CPSC · 2026-09-24What these figures mean
How this compares
The closest models in the same class — same fuel, type and draw pattern.
Keep going
How every figure on this page is calculated
-
Find what replaces your water heater
Enter the model number off your old unit and see what is on file today, with the yearly cost difference.
-
Find a water heater that fits
Three questions — fuel, hot water need, install space — narrow every model on file to the ones that fit.
-
What a water heater costs to run
Prices a unit's efficiency against your own utility's filed tariff for your ZIP code.
-
How to size a tankless water heater by GPM
Answered from what models in this size actually file.
-
Water heaters
Every model on file with the Department of Energy, by heater type.
-
All electric tankless water heaters
Electric instantaneous units, sized by flow rate rather than tank gallons.
-
Every EEMAX model on file
What this brand files, by heater type.
UEF 0.98 · Grade D Price it on your ZIP
The registry lists a UEF, the ratio of hot water delivered to energy used, of 0.98 for the EEMAX SPEX95T. This site did not copy the annual energy figure from the registry. It computed 603 kWh of electricity from that UEF and the daily hot-water draw in the DOE test for the very small draw pattern. The source is DOE CCD, retrieved 2026-09-19. Against the 271 electric tankless models registered at the same draw pattern, the median is 615 kWh, so this unit sits 12 kWh below it. Its rank of 10th lowest puts it in the lowest quarter of its class for energy use. The registry also lists a maximum flow rate in gallons per minute of 0.9.
The very small draw pattern describes small units, such as a single bathroom or a point-of-use heater under a sink. The 603 kWh figure fits that use and no other, because the test draw is fixed for the pattern. If the real hot-water use in a home is larger than the test draw, the figure no longer describes that home, and this page has no data on by how much. The maximum flow rate of 0.9 is a registry rating; it does not show how many fixtures the unit can serve at once. For a different fuel, space or size, the water heater selector filters by those inputs. To find a same-class replacement for this unit, the replacement finder starts from a model number.
The running cost is not printed here because it depends on your own utility electricity tariff. It is the annual energy of 603 kWh priced at your rate, and the registry does not hold that rate. The cost calculator takes your ZIP and applies the local rate to this figure. The steps behind that calculation are in the methodology. The margin of 12 kWh below the class median of 615 kWh is a difference in energy, not in cost; whether it changes a bill depends on the same rate. The modeled installed-cost range appears in its own block with its source and date, as an estimate and not a quote. It is not repeated in this text.
DOE CCD · 2026-09-19