ARISTON EVR052*2X***
0.93 UEF DOE CCD · 2026-09-19Grade G: where this UEF sits among the 426 models in its class, lowest (G) to highest (A). A position, not an official label. How the grade is set
An electric tank, medium draw pattern (a typical three- or four-person household, about 55 gallons on a busy morning).
If you are verifying the ARISTON EVR052*2X***, an electric tank water heater, this site calculates 3,493 kWh of electricity a year. That figure applies to the medium draw pattern, the standard daily hot-water usage DOE tests against. It sits 38 kWh below the 3,531 kWh median of its class.
Energy use per year
3,493 kWh a year
Computed by this site from the registry's UEF and the federal test's daily hot-water draw for this draw pattern. What it costs depends on the electricity rate where you live.
That is below the median of 3,531 kWh for the 426 models registered in the same heater type and draw pattern; it ranks 153 of 426, lowest energy first.
Solid line: this model (3,493 kWh). Dashed line: the class median.
Min 773 kWh Median 3,531 kWh Max 3,569 kWh
What it costs to run where you live
What the registry files
- UEF (Uniform Energy Factor) how much hot water you get for each unit of energy the heater uses
- 0.93 DOE CCD · 2026-09-19 Compared only with other models registered as an electric tank at the medium draw pattern.
- Draw Pattern the standard daily usage profile DOE tests the unit against
- Medium DOE CCD · 2026-09-19
- First Hour Rating how many gallons of hot water the unit can deliver in one hour, starting from a full tank
- 62 gal DOE CCD · 2026-09-19
- Rated Storage Volume the tank size in gallons
- 48 gal DOE CCD · 2026-09-19
What it costs to install
$1,771–$2,320 installed
Not a quote — a modeled range of what installers have charged for this class of unit; your price will vary with labor rates, access, and local code requirements.
Escalation indexes: equipment (BLS PPI) latest available: August 2026; labor (BLS ECI) latest available: April 2026 to June 2026.
NLR REMDB (BLS PPI/ECI escalated) · 2026-04-01Safety record
No CPSC recall names this model.
Checked against the CPSC recall database. CPSC does not publish a model-level match for this product category, so this list is curated by hand from the manufacturer's recall filings.
CPSC · 2026-09-24What these figures mean
How this compares
The closest models in the same class — same fuel, type and draw pattern.
Keep going
How every figure on this page is calculated
-
Find what replaces your water heater
Enter the model number off your old unit and see what is on file today, with the yearly cost difference.
-
Find a water heater that fits
Three questions — fuel, hot water need, install space — narrow every model on file to the ones that fit.
-
What a water heater costs to run
Prices a unit's efficiency against your own utility's filed tariff for your ZIP code.
-
Is a 50-gallon water heater enough?
Answered from what models in this size actually file.
-
Water heaters
Every model on file with the Department of Energy, by heater type.
-
All electric resistance tank water heaters
Electric tanks that file a UEF below 2.0 — heated by elements, not a heat pump.
-
Every ARISTON model on file
What this brand files, by heater type.
UEF 0.93 · Grade G Price it on your ZIP
The 3,493 kWh figure does not come from the registry. This site computed it from the registry's UEF, the ratio of hot water delivered to energy used. It combined that ratio with the DOE test's daily hot-water draw for the medium draw pattern. For the EVR052*2X***, the UEF is 0.93 and the rated volume is 48 gallons. The inputs come from the DOE CCD, retrieved 2026-09-19. The medium pattern represents a typical mid-sized household with a busy morning. A home that draws more or less hot water than the test assumes will use a different amount of electricity. This data does not show how large that difference would be for any given home. The calculation steps are set out in how the annual cost is calculated.
Its class is the 426 models registered as an electric tank at the medium draw pattern. Among them, this model ranks 153rd lowest in energy use. The class median is 3,531 kWh a year, and this model sits 38 kWh below it. A rank of 153rd also means other models in the class use less energy. Its first hour rating, the gallons of hot water available in the first hour from a full tank, is 62 gallons. These figures describe a household whose morning demand matches the medium pattern and stays within that rating. A household that needs more than 62 gallons in the first hour falls outside what these figures describe. To check other models in the same class, use the same-class replacement finder by model number.
This text does not state the running cost of 3,493 kWh a year. That cost depends on your own utility's electricity tariff. The page computes it from your ZIP in the running-cost calculator for your ZIP. Your tariff also sets what the 38 kWh gap from the class median is worth. The installed price range appears on this page in its own block, with its source and date. It is a modeled installed-cost range, not a quote. If the EVR052*2X*** does not fit your fuel, space or size, the water heater selector by fuel, space and size lists other models.
DOE CCD · 2026-09-19