DoesTheMath

AMERICAN HPTU-50N 1**

3.45 UEF DOE CCD · 2026-09-19
B

Grade B: where this UEF sits among the 426 models in its class, lowest (G) to highest (A). A position, not an official label. How the grade is set

An electric tank, medium draw pattern (a typical three- or four-person household, about 55 gallons on a busy morning).

If you are checking this unit against a spec sheet: AMERICAN HPTU-50N 1** uses 942 kWh of electricity a year at the medium draw pattern, the standard daily hot-water usage DOE tests against. That is 2,589 kWh below the class median of 3,531 kWh.


Energy use per year

942 kWh a year

Computed by this site from the registry's UEF and the federal test's daily hot-water draw for this draw pattern. What it costs depends on the electricity rate where you live.

That is below the median of 3,531 kWh for the 426 models registered in the same heater type and draw pattern; it ranks 93 of 426, lowest energy first.

This model: 942 kWh

Solid line: this model (942 kWh). Dashed line: the class median.

Min 773 kWh Median 3,531 kWh Max 3,569 kWh

DOE CCD · 2026-09-19

Report an issue with this number


What it costs to run where you live

Enter your ZIP to see what this unit costs to run a year on your own utility’s electricity rate.


What the registry files

UEF (Uniform Energy Factor) how much hot water you get for each unit of energy the heater uses
3.45 DOE CCD · 2026-09-19 Compared only with other models registered as an electric tank at the medium draw pattern.
Draw Pattern the standard daily usage profile DOE tests the unit against
Medium DOE CCD · 2026-09-19
First Hour Rating how many gallons of hot water the unit can deliver in one hour, starting from a full tank
66 gal DOE CCD · 2026-09-19
Rated Storage Volume the tank size in gallons
46 gal DOE CCD · 2026-09-19
On the market since (ENERGY STAR) the date the manufacturer told ENERGY STAR the model went on sale
2019-04-05 ENERGY STAR · 2026-09-19
Connected / demand response (ENERGY STAR) whether the unit can take signals from your utility to shift when it heats, and by which standard (such as CTA-2045)
No ENERGY STAR · 2026-09-19
Refrigerant and GWP (ENERGY STAR) the refrigerant a heat pump unit uses and its global warming potential, a leak's climate effect relative to carbon dioxide (CO2 = 1)
R-134a, GWP 1430 ENERGY STAR · 2026-09-19

What it costs to install

$3,022–$4,110 installed

Not a quote — a modeled range of what installers have charged for this class of unit; your price will vary with labor rates, access, and local code requirements.

Escalation indexes: equipment (BLS PPI) latest available: August 2026; labor (BLS ECI) latest available: April 2026 to June 2026.

NLR REMDB (BLS PPI/ECI escalated) · 2026-04-01

Report an issue with this number


Safety record

No CPSC recall names this model.

Checked against the CPSC recall database. CPSC does not publish a model-level match for this product category, so this list is curated by hand from the manufacturer's recall filings.

CPSC · 2026-09-24

Does it fit your space?

Enter your own numbers below — this compares them to what ENERGY STAR publishes for this model, it does not tell you what to buy.

Compressor operating range (ENERGY STAR)
the air temperatures around the unit in which its heat pump runs; outside this range the heat pump stops
Dimensions (ENERGY STAR)
the unit's filed height, width, depth or tank diameter, in inches
Input voltage and maximum current (ENERGY STAR)
the circuit voltage the unit is certified on and the most current it draws
  • Ambient temperatureEnter your numbers45°F min
  • Physical footprintEnter your numbers15" ⌀
  • Electrical supplyEnter your numbers240V, 22A max
ENERGY STAR · 2026-09-19

What these figures mean

The figure of 942 kWh was computed by this site, not by the registry. It combines the registry's UEF, the ratio of hot water delivered to energy used, with the daily hot-water draw of the federal test. The model's UEF is 3.45. The figure holds only for the medium draw pattern, meaning a typical three- or four-person household on a busy morning. Among the 426 electric tank models registered at that pattern, this one ranks 93rd lowest for energy use. That puts it in the lowest quarter of its class. The source is DOE CCD, retrieved 2026-09-19.

Its first hour rating, the gallons of hot water available in the first hour from a full tank, is 66 gallons. The rated volume is 46 gallons. Those figures are the ones to compare with your own peak demand. The energy figure suits a household whose use resembles the medium draw pattern. It does not describe a household that draws more or less hot water each day. For those cases, the energy use of this model is not available here. Treat 942 kWh as a reference only. To check the size and fuel of a different unit, use the water heater selector by fuel, space and size. To find a same-class replacement, enter the model number in the same-class replacement finder.

Running cost depends on your own utility electricity tariff, so this text states no cost figure. The cost calculator on your own ZIP applies your rate to 942 kWh. The method is explained under how the annual cost is calculated. The gap of 2,589 kWh from the class median of 3,531 kWh is a difference in kilowatt-hours. Its value in cost terms follows your rate. The installed price range appears in its own block with its source and date. It is a modeled installed-cost range, not a quote, so its figures are not repeated here. This page makes no claim about other draw patterns. The comparison of 426 models covers only electric tanks at the medium draw pattern.

DOE CCD · 2026-09-19

How this compares

The closest models in the same class — same fuel, type and draw pattern.


Keep going

UEF 3.45 · Grade B Price it on your ZIP