DoesTheMath

AMERICAN HPTA-50 2**

3.68 UEF DOE CCD · 2026-09-19
B

Grade B: where this UEF sits among the 426 models in its class, lowest (G) to highest (A). A position, not an official label. How the grade is set

An electric tank, medium draw pattern (a typical three- or four-person household, about 55 gallons on a busy morning).

Checking this model's energy use: AMERICAN HPTA-50 2**, an electric tank, uses 883 kWh a year at the medium draw pattern, the standard daily hot-water usage DOE tests against. That is 2,648 kWh below the class median of 3,531 kWh among 426 electric tank models. It ranks 48th lowest for energy use.


Energy use per year

883 kWh a year

Computed by this site from the registry's UEF and the federal test's daily hot-water draw for this draw pattern. What it costs depends on the electricity rate where you live.

That is below the median of 3,531 kWh for the 426 models registered in the same heater type and draw pattern; it ranks 48 of 426, lowest energy first.

This model: 883 kWh

Solid line: this model (883 kWh). Dashed line: the class median.

Min 773 kWh Median 3,531 kWh Max 3,569 kWh

DOE CCD · 2026-09-19

Report an issue with this number


What it costs to run where you live

Enter your ZIP to see what this unit costs to run a year on your own utility’s electricity rate.


What the registry files

UEF (Uniform Energy Factor) how much hot water you get for each unit of energy the heater uses
3.68 DOE CCD · 2026-09-19 Compared only with other models registered as an electric tank at the medium draw pattern.
Draw Pattern the standard daily usage profile DOE tests the unit against
Medium DOE CCD · 2026-09-19
First Hour Rating how many gallons of hot water the unit can deliver in one hour, starting from a full tank
65 gal DOE CCD · 2026-09-19
Rated Storage Volume the tank size in gallons
46 gal DOE CCD · 2026-09-19
On the market since (ENERGY STAR) the date the manufacturer told ENERGY STAR the model went on sale
2024-03-01 ENERGY STAR · 2026-09-19
Connected / demand response (ENERGY STAR) whether the unit can take signals from your utility to shift when it heats, and by which standard (such as CTA-2045)
Yes (CTA-2045-A,CTA-2045-B) ENERGY STAR · 2026-09-19
Refrigerant and GWP (ENERGY STAR) the refrigerant a heat pump unit uses and its global warming potential, a leak's climate effect relative to carbon dioxide (CO2 = 1)
R-134a, GWP 1430 ENERGY STAR · 2026-09-19

What it costs to install

$3,049–$4,340 installed

Not a quote — a modeled range of what installers have charged for this class of unit; your price will vary with labor rates, access, and local code requirements.

Escalation indexes: equipment (BLS PPI) latest available: August 2026; labor (BLS ECI) latest available: April 2026 to June 2026.

NLR REMDB (BLS PPI/ECI escalated) · 2026-04-01

Report an issue with this number


Safety record

No CPSC recall names this model.

Checked against the CPSC recall database. CPSC does not publish a model-level match for this product category, so this list is curated by hand from the manufacturer's recall filings.

CPSC · 2026-09-24

Does it fit your space?

Enter your own numbers below — this compares them to what ENERGY STAR publishes for this model, it does not tell you what to buy.

Compressor operating range (ENERGY STAR)
the air temperatures around the unit in which its heat pump runs; outside this range the heat pump stops
Dimensions (ENERGY STAR)
the unit's filed height, width, depth or tank diameter, in inches
Input voltage and maximum current (ENERGY STAR)
the circuit voltage the unit is certified on and the most current it draws
  • Ambient temperatureEnter your numbers37°F min
  • Physical footprintEnter your numbers15" ⌀
  • Electrical supplyEnter your numbers240V, 22A max
ENERGY STAR · 2026-09-19

What these figures mean

The registry lists a UEF, the ratio of hot water delivered to energy used, of 3.68 for this model. This site computed 883 kWh a year from that UEF and the DOE test's daily hot-water draw for the medium draw pattern; the registry does not publish that figure itself. The source is DOE CCD, retrieved 2026-09-19. The result is 2,648 kWh below the class median of 3,531 kWh. Ranked by energy use, the model is 48th lowest of 426, which places it in the lowest quarter of its class. The comparison covers only models registered as an electric tank at the medium draw pattern, so it says nothing about other fuels or other draw patterns. How the annual cost is calculated is set out on the methodology page.

The first hour rating, the gallons of hot water available in the first hour from a full tank, is 65 gallons, and the rated volume is 46 gallons. The medium draw pattern describes a typical three- or four-person household on a busy morning, and the 883 kWh figure applies to that pattern only. It is relevant to readers checking a unit of this size against that household. It does not cover households with a different daily draw, and the data give no annual energy for other draw patterns. The figure is a test-based calculation, not a measurement in a home. Readers sorting by fuel, space or size can use the water heater selector by fuel, space and size.

Running cost is not stated here because it depends on your own utility electricity tariff. It is the 883 kWh figure multiplied by your rate, and that rate is not in the data. The cost calculator on your ZIP computes it. The installed price range appears in its own block with its source and date; it is a modeled installed-cost range, not a quote. The model uses 2,648 kWh less than the class median of 3,531 kWh. The same rate applies to a smaller quantity of energy, but the cost difference depends on that rate. To compare against other units in its class, find a same-class replacement by model number. The limit of this page is that 883 kWh is a calculation at the federal test's draw, not a reading from a home.

DOE CCD · 2026-09-19

How this compares

The closest models in the same class — same fuel, type and draw pattern.


Keep going