DoesTheMath

AMERICAN ENJ-40W 1**

0.91 UEF DOE CCD · 2026-09-19
G

Grade G: where this UEF sits among the 163 models in its class, lowest (G) to highest (A). A position, not an official label. How the grade is set

An electric tank, low draw pattern (a one- or two-person household).

If you are checking the AMERICAN ENJ-40W 1**, it uses 2,466 kWh of electricity a year at the low draw pattern, the standard daily hot-water usage DOE tests against. That is 27 kWh above the 2,439 kWh median of the 163 electric tank models registered at the same pattern, ranking 88th lowest in energy use of 163.


Energy use per year

2,466 kWh a year

Computed by this site from the registry's UEF and the federal test's daily hot-water draw for this draw pattern. What it costs depends on the electricity rate where you live.

That is above the median of 2,439 kWh for the 163 models registered in the same heater type and draw pattern; it ranks 88 of 163, lowest energy first.

This model: 2,466 kWh

Solid line: this model (2,466 kWh). Dashed line: the class median.

Min 724 kWh Median 2,439 kWh Max 2,550 kWh

DOE CCD · 2026-09-19

Report an issue with this number


What it costs to run where you live

Enter your ZIP to see what this unit costs to run a year on your own utility’s electricity rate.


What the registry files

UEF (Uniform Energy Factor) how much hot water you get for each unit of energy the heater uses
0.91 DOE CCD · 2026-09-19 Compared only with other models registered as an electric tank at the low draw pattern.
Draw Pattern the standard daily usage profile DOE tests the unit against
Low DOE CCD · 2026-09-19
First Hour Rating how many gallons of hot water the unit can deliver in one hour, starting from a full tank
38 gal DOE CCD · 2026-09-19
Rated Storage Volume the tank size in gallons
35 gal DOE CCD · 2026-09-19

What it costs to install

Not published: Installed cost range

This model's UEF lies outside the range NLR REMDB's cost model was fitted on, and the range is not stretched past it.

The annual energy figure on this page does not depend on this range and is unaffected.


Safety record

No CPSC recall names this model.

Checked against the CPSC recall database. CPSC does not publish a model-level match for this product category, so this list is curated by hand from the manufacturer's recall filings.

CPSC · 2026-09-24

What these figures mean

The 2,466 kWh per year is a figure this site computes, not one the registry publishes. It combines the registry's UEF, the ratio of hot water delivered to energy used, with the daily hot-water draw the DOE test sets for the low draw pattern. For the ENJ-40W 1**, the UEF is 0.91. Both inputs come from the DOE CCD, retrieved 2026-09-19. The result therefore applies only at the federal test's daily draw. It does not describe a home whose daily hot-water use differs from that test draw, and no separate figure for such a home is available here. The steps behind the number are set out in how this site calculates annual energy and cost.

This unit is rated at the low draw pattern, which DOE uses to represent a small household. Its first hour rating, the gallons of hot water available in the first hour from a full tank, is 38 gallons, from a rated volume of 35 gallons. Among the 163 electric tank models registered at the low pattern, it ranks 88th lowest in energy use. Its 2,466 kWh sits 27 kWh above the class median of 2,439 kWh. That places it in the quarter just above the middle of its class. A home drawing more hot water each day than the low pattern falls outside the condition these figures describe. To check other units, use the same-class replacement search by model number or the water heater selector by fuel, space and size.

The running cost of the 2,466 kWh is not stated in this text. It depends on your own utility electricity tariff, so the page computes it from your ZIP instead. Enter it in the running-cost calculator for your ZIP to see the figure on your rate. An installed price range is not published for the ENJ-40W 1** either. This model's ratings lie outside the range the cost database's model was fitted on, and the range is not stretched past it. The installed price is therefore unknown here. The 27 kWh gap to the class median is an energy difference at the test draw only. What that gap costs a year also depends on your tariff, so it is not given here.

DOE CCD · 2026-09-19

How this compares

The closest models in the same class — same fuel, type and draw pattern.


Keep going