DoesTheMath

AMERICAN ATM-199M-N 1**

0.95 UEF DOE CCD · 2026-09-19
B

Grade B: where this UEF sits among the 397 models in its class, lowest (G) to highest (A). A position, not an official label. How the grade is set

A gas tankless unit, high draw pattern (a larger household, or one where showers and laundry overlap).

If you are checking whether this unit suits a larger household, the AMERICAN ATM-199M-N 1** uses 178 therms of natural gas a year at the high draw pattern, the standard daily hot-water usage DOE tests against. That is 4 therms below its class median of 182 therms.


Energy use per year

178 therms a year

Computed by this site from the registry's UEF and the federal test's daily hot-water draw for this draw pattern. What it costs depends on the natural gas rate where you live.

That is below the median of 182 therms for the 397 models registered in the same heater type and draw pattern; it ranks 45 of 397, lowest energy first.

This model: 178 therms

Solid line: this model (178 therms). Dashed line: the class median.

Min 173 therms Median 182 therms Max 209 therms

DOE CCD · 2026-09-19

Report an issue with this number


What it costs to run where you live

Enter your ZIP to see what this unit costs to run a year at your state’s average natural gas price.


What the registry files

UEF (Uniform Energy Factor) how much hot water you get for each unit of energy the heater uses
0.95 DOE CCD · 2026-09-19 Compared only with other models registered as a gas tankless unit at the high draw pattern.
Draw Pattern the standard daily usage profile DOE tests the unit against
High DOE CCD · 2026-09-19
Maximum Gallons Per Minute how many gallons a minute it can heat while running continuously
6 gal/min DOE CCD · 2026-09-19
On the market since (ENERGY STAR) the date the manufacturer told ENERGY STAR the model went on sale
2025-05-15 ENERGY STAR · 2026-09-19
Connected / demand response (ENERGY STAR) whether the unit can take signals from your utility to shift when it heats, and by which standard (such as CTA-2045)
No ENERGY STAR · 2026-09-19

What it costs to install

$2,358–$3,405 installed

Not a quote — a modeled range of what installers have charged for this class of unit; your price will vary with labor rates, access, and local code requirements.

Escalation indexes: equipment (BLS PPI) latest available: August 2026; labor (BLS ECI) latest available: April 2026 to June 2026.

NLR REMDB (BLS PPI/ECI escalated) · 2026-04-01

Report an issue with this number


Safety record

No CPSC recall names this model.

Checked against the CPSC recall database. CPSC does not publish a model-level match for this product category, so this list is curated by hand from the manufacturer's recall filings.

CPSC · 2026-09-24

Does it fit your space?

Enter your own numbers below — this compares them to what ENERGY STAR publishes for this model, it does not tell you what to buy.

Dimensions (ENERGY STAR)
the unit's filed height, width, depth or tank diameter, in inches
Input voltage and maximum current (ENERGY STAR)
the circuit voltage the unit is certified on and the most current it draws
Vent type and size (ENERGY STAR)
how a gas unit is vented, the vent's diameter and the height of its vent connector
  • Physical footprintEnter your numbers27" H × 17.3" W × 12" D × 1" ⌀
  • Electrical supplyEnter your numbers5A max
  • Vent compatibilityEnter your numbersPower Vent or Power Direct Vent, 3" or 2" vent, 1" to vent
ENERGY STAR · 2026-09-19

What these figures mean

The registry lists this gas tankless unit with a UEF, the ratio of hot water delivered to energy used, of 0.95. Its maximum flow rate in gallons per minute is 6. The annual figure of 178 therms of natural gas is not a registry value. This site computed it from the registry's UEF and the DOE test's daily hot-water draw for the high draw pattern, which describes a larger household or one where showers and laundry overlap. The figure applies only at that draw. The energy data comes from DOE CCD, retrieved 2026-09-19.

Among the 397 models registered as a gas tankless unit at the high draw pattern, this one has the 45th lowest energy use of 397. That places it in the lowest quarter of its class. Its 178 therms sits 4 therms below the class median of 182 therms, so the gap from the median is small. The figure fits a household whose use matches the high draw pattern. For lighter use this page has no figure, and that value is not available. The maximum flow rate of 6 gallons per minute is a rating, and this page does not test whether it covers overlapping showers. The selector by fuel, space and size can narrow other options.

Running cost is not stated here because it depends on your state's average residential gas price, which is not part of this model's data. To apply 178 therms at the high draw pattern to your own rate, use the cost calculator on your ZIP. The page on how the annual cost is calculated sets out the method. The modeled installed-cost range for ATM-199M-N 1** appears in its own block with its source and date. It is a modeled range, not a quote. To compare against a same-class unit, you can find a replacement by model number.

DOE CCD · 2026-09-19

How this compares

The closest models in the same class — same fuel, type and draw pattern.


Keep going

UEF 0.95 · Grade B Price it on your ZIP